Reliability and validity of hand-held dynamometry for assessing lower limb muscle strength

被引:10
作者
Lipovsek, Tjasa [1 ]
Kacin, Alan [1 ]
Puh, Urska [1 ]
机构
[1] Univ Ljubljana, Fac Hlth Sci, Dept Physiotherapy, Ljubljana, Slovenia
关键词
Muscle strength; isometric contraction; dynamometer; reliability; validity; KNEE-JOINT ANGLE; EXTREMITY; PERFORMANCE; FLEXION; VALUES;
D O I
10.3233/IES-210168
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
BACKGROUND: Hand-held dynamometry (HHD) is used to assess muscle strength in various patient populations, but many variations in protocols exist. OBJECTIVE: First, to systematically develop a protocol of HHD for all lower limb muscle groups and evaluate intra-rater reliability; second, to validate HHD with fixed dynamometry for the knee flexor and extensor muscles. METHODS: Thirty healthy young adults (women: men - 15:15) participated in two testing sessions. HHD of 12 lower limb muscle groups was performed in both sessions, while fixed dynamometry of knee muscle groups was performed only in the second session. RESULTS: The intra-rater reliability of HHD was good for five muscle groups and excellent for seven muscle groups (ICC3, k = 0.80-0.96). The criterion validity of HHD ranged from very good to excellent for the knee flexors (r = 0.77-0.89) and from good to very good for the knee extensors (r = 0.65-0.78). However, peak moment values for the knee extensor muscles were underestimated by 32% (p < 0.001). CONCLUSIONS: The proposed HHD protocol provides reliable and valid measurements of lower limb muscle isometric strength in healthy adults, which may also be used to test patients with mild muscle strength deficits. However, possible underestimation of absolute strength must be considered when interpreting the results of knee extensors or other large muscles.
引用
收藏
页码:231 / 240
页数:10
相关论文
共 50 条
[41]   INTERRATER RELIABILITY OF HAND-HELD DYNAMOMETRY - EFFECTS OF RATER GENDER, BODY-WEIGHT, AND GRIP STRENGTH [J].
WADSWORTH, CT ;
NIELSEN, DH ;
CORCORAN, DS ;
PHILLIPS, CE ;
SANNES, TL .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1992, 16 (02) :74-81
[42]   Foot and Ankle Strength Assessment Using Hand-Held Dynamometry: Reliability and Age-Related Differences [J].
Spink, Martin J. ;
Fotoohabadi, Mohammad R. ;
Menz, Hylton B. .
GERONTOLOGY, 2010, 56 (06) :525-532
[43]   Hand-held Dynamometry Correlation With the Gold Standard Isokinetic Dynamometry: A Systematic Review [J].
Stark, Timothy ;
Walker, Bruce ;
Phillips, Jacqueline K. ;
Fejer, Rene ;
Beck, Randy .
PM&R, 2011, 3 (05) :472-479
[44]   Maximal isometric muscle strength values obtained By hand-held dynamometry in children between 6 and 15 years of age [J].
Escobar, Raul G. ;
Munoz, Karin T. ;
Dominguez, Angelica ;
Banados, Pamela ;
Bravo, Maria J. .
MUSCLE & NERVE, 2017, 55 (01) :16-22
[45]   Variability between Different Hand-Held Dynamometers for Measuring Muscle Strength [J].
Du, William ;
Cornett, Kayla M. D. ;
Donlevy, Gabrielle A. ;
Burns, Joshua ;
Mckay, Marnee J. .
SENSORS, 2024, 24 (06)
[46]   Reliability of Hand-Held Dynamometer for assessing Isometric Lumbar Muscles Strength in Asymptomatic Healthy Population [J].
Tanveer, Fahad ;
Arslan, Syed Asadullah ;
Darain, Haider ;
Ahmad, Ashfaq .
PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2021, 37 (02) :461-465
[47]   VALIDITY AND RELIABILITY OF A HAND-HELD DYNAMOMETER WITH 2 POPULATIONS [J].
SURBURG, PR ;
SUOMI, R ;
POPPY, WK .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1992, 16 (05) :229-234
[48]   Comparison of maximal voluntary isometric contraction and hand-held dynamometry in measuring muscle strength of patients with progressive lower motor neuron syndrome [J].
Visser, J ;
Mans, E ;
de Visser, JM ;
van den Berg-Vos, RM ;
Franssen, H ;
de Jong, JMBV ;
van den Berg, LH ;
Wokke, JHJ ;
de Haan, RJ .
NEUROMUSCULAR DISORDERS, 2003, 13 (09) :744-750
[49]   Hip extension strength measured using hand-held dynamometry in a rehabilitation setting [J].
Cardin, Grace ;
Bohannon, Richard W. .
ISOKINETICS AND EXERCISE SCIENCE, 2017, 25 (02) :157-160
[50]   Test-retest reliability of hand-held dynamometry and functional tests in systemic lupus erythematosus [J].
Stockton, K. A. ;
Wrigley, T. V. ;
Mengersen, K. A. ;
Kandiah, D. A. ;
Paratz, J. D. ;
Bennell, K. L. .
LUPUS, 2011, 20 (02) :144-150