A comparison of two antimicrobial-impregnated central venous catheters

被引:527
作者
Darouiche, RO
Raad, II
Heard, SO
Thornby, JI
Wenker, OC
Gabrielli, A
Berg, J
Khardori, N
Hanna, H
Hachem, R
Harris, RL
Mayhall, G
机构
[1] Vet Affairs Med Ctr, Infect Dis Sect, Houston, TX 77030 USA
[2] Baylor Coll Med, Dept Med, Houston, TX 77030 USA
[3] Baylor Coll Med, Dept Phys Med & Rehabil, Houston, TX 77030 USA
[4] Baylor Coll Med, Dept Family & Community Med, Houston, TX 77030 USA
[5] Baylor Coll Med, Dept Anesthesiol, Houston, TX 77030 USA
[6] Univ Texas, MD Anderson Canc Ctr, Dept Med Subspecialties, Houston, TX USA
[7] Univ Massachusetts, Med Ctr, Dept Anesthesiol, Worcester, MA USA
[8] Univ Florida, Coll Med, Dept Surg, Gainesville, FL USA
[9] Univ Florida, Coll Med, Dept Med, Gainesville, FL USA
[10] So Illinois Univ, Sch Med, Dept Med, Springfield, IL 62708 USA
[11] Univ Texas, Med Branch, Dept Med, Galveston, TX 77550 USA
关键词
D O I
10.1056/NEJM199901073400101
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The use of central venous catheters impregnated with either minocycline and rifampin or chlorhexidine and silver sulfadiazine reduces the rates of catheter colonization and catheter-related bloodstream infection as compared with the use of unimpregnated catheters. We compared the rates of catheter colonization and catheter-related bloodstream infection associated with these two kinds of antiinfective catheters. Methods We conducted a prospective, randomized clinical trial in 12 university-affiliate hospitals. High-risk adult patients in whom central venous catheters were expected to remain in place for three or more days were randomly assigned to undergo insertion of polyurethane, triple-lumen catheters impregnated with either minocycline and rifampin ton both the luminal and external surfaces) or chlorhexidine and silver sulfadiazine ton only the external surface). After their removal, the tips and subcutaneous segments of the catheters were cultured by both the roll-plate and the sonication methods. Peripheral-blood cultures were obtained if clinically indicated. Results Of 865 catheters inserted, 738 (85 percent) produced culture results that could be evaluated. The clinical characteristics of the patients and the risk factors for infection were similar in the two groups. Catheters impregnated with minocycline and rifampin were 1/3 as likely to be colonized as catheters impregnated with chlorhexidine and silver sulfadiazine (28 of 356 catheters [7.9 percent] vs. 87 of 382 [22.8 percent], P<0.001), and catheter-related bloodstream infection was 1/12 as likely in catheters impregnated with minocycline and rifampin (1 of 356 [0.3 percent], vs. 13 of 382 [3.4 percent] for those impregnated with chlorhexidine and silver sulfadiazine; P<0.002). Conclusions The use of central venous catheters impregnated with minocycline and rifampin is associated with a lower rate of infection than the use of catheters impregnated with chlorhexidine and silver sulfadiazine. (N Engl J Med 1999;340:1-8.) (C) 1999, Massachusetts Medical Society.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 19 条
  • [1] Characterization of two unusual clinically significant Francisella strains
    Clarridge, JE
    Raich, TJ
    Sjosted, A
    Sandstrom, G
    Darouiche, RO
    Shawar, RM
    Georghiou, PR
    Osting, C
    Vo, L
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (08) : 1995 - 2000
  • [2] Influence of triple-lumen central venous catheters coated with chlorhexidine and silver sulfadiazine on the incidence of catheter-related bacteremia
    Heard, SO
    Wagle, M
    Vijayakumar, E
    McLean, S
    Brueggemann, A
    Napolitano, LM
    Edwards, LP
    O'Connell, FM
    Puyana, JC
    Doern, GV
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1998, 158 (01) : 81 - 87
  • [3] Prevention of central venous catheter-related bloodstream infection by use of an antiseptic-impregnated catheter - A randomized, controlled trial
    Maki, DG
    Stolz, SM
    Wheeler, S
    Mermel, LA
    [J]. ANNALS OF INTERNAL MEDICINE, 1997, 127 (04) : 257 - +
  • [4] SEMIQUANTITATIVE CULTURE METHOD FOR IDENTIFYING INTRAVENOUS-CATHETER-RELATED INFECTION
    MAKI, DG
    WEISE, CE
    SARAFIN, HW
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1977, 296 (23) : 1305 - 1309
  • [5] National Committee for Clinical Laboratory Standards (NCCLS), 1997, METH DIL ANT SUSC TE, V17
  • [6] Pearson ML, 1996, AM J INFECT CONTROL, V24, P262
  • [7] PEARSON ML, 1996, AM J INFECT CONTROL, V24, P277
  • [8] Pemberton LB, 1996, ARCH SURG-CHICAGO, V131, P986
  • [9] NOSOCOMIAL BLOOD-STREAM INFECTION IN CRITICALLY ILL PATIENTS - EXCESS LENGTH OF STAY, EXTRA COSTS, AND ATTRIBUTABLE MORTALITY
    PITTET, D
    TARARA, D
    WENZEL, RP
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 271 (20): : 1598 - 1601
  • [10] The broad-spectrum activity and efficacy of catheters coated with minocycline and rifampin
    Raad, I
    Darouiche, R
    Hachem, R
    Mansouri, M
    Bodey, GP
    [J]. JOURNAL OF INFECTIOUS DISEASES, 1996, 173 (02) : 418 - 424