Catheter-associated urinary tract infection reduction in critical care units: a bundled care model

被引:38
作者
Van Decker, Stephanie Grana [1 ]
Bosch, Nicholas [2 ]
Murphy, Jaime [2 ]
机构
[1] Boston Med Ctr, Dept Internal Med, Boston, MA 02118 USA
[2] Boston Med Ctr, Dept Pulm Allergy Sleep & Crit Care Med, Boston, MA USA
关键词
quality improvement methodologies; quality measurement; healthcare quality improvement; control charts; run charts; quality improvement; QUALITY; DEVICE;
D O I
10.1136/bmjoq-2021-001534
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Catheter-associated urinary tract infections (CAUTIs) represent approximately 9% of all hospital acquired infections, and approximately 65%-70% of CAUTIs are believed to be preventable. In the spring of 2013, Boston Medical Center (BMC) began an initiative to decrease CAUTI rates within its intensive care units (ICUs). A CAUTI taskforce convened and reviewed process maps and gap analyses. Based on Centers for Disease Control and Prevention (CDC) and Institute for Healthcare Improvement (IHI) guidelines, and delineated by the Healthcare Infection Control Practices Advisory Committee 2009 guidelines, all BMC ICUs sequentially implemented plan-do-study-act cycles based on which measures were most easily adaptable and believed to have the highest impact on CAUTI rates. Implementation of five care bundles spanned 5 years and included (1) processes for insertion and maintenance of foley catheters; (2) indications for indwelling foley catheters; (3) appropriate testing for CAUTIs; (4) alternatives to indwelling devices; and (5) sterilisation techniques. Daily rounds by unit nursing supervisors and inclusion of foley catheter necessity on daily ICU checklists held staff accountable on a daily basis. With these interventions, the total number of CAUTIs at BMC decreased from 53 in 2013 to 9 in 2017 (83% reduction) with a 33.8% reduction in indwelling foley catheter utilisation during the same time period. Adapted protocols showed success in decreasing the CAUTI rate and indwelling foley catheter usage in all of the BMC ICU's. While all interventions had favourable and additive trends towards decreasing the CAUTI rate, the CAUTI awareness education, insertion and removal protocols and implementation of PureWick female incontinence devices had clear and significant effects on decreasing CAUTI rates. Our project provides a framework for improving HAIs using rapid cycle testing and U-chart data monitoring. Targeted education efforts and standardised checklists and protocols adapted sequentially are low-cost and high yield efforts that may decrease CAUTIs in ICU settings.
引用
收藏
页数:7
相关论文
共 38 条
[1]  
[Anonymous], 2019, Urinary tract infection (Catheter-associated urinary tract infection [CAUTI] and non-catheter-associated urinary tract infection [UTI]) and other urinary system infection [USI]) events
[2]   Urinary Management With an External Female Collection Device [J].
Beeson, Terrie ;
Davis, Carmen .
JOURNAL OF WOUND OSTOMY AND CONTINENCE NURSING, 2018, 45 (02) :187-189
[3]  
Blanck A.M., 2014, Journal of Hospital Administration, V3, P101, DOI [DOI 10.5430/JHA.V3N4P101, 10.5430/jha.v3n4p10, DOI 10.5430/JHA.V3N4P10]
[4]  
Bleeker E., 2019, External catheters and reducing adverse effects in female inpatients
[5]  
*BOST MED CTR, 2017, BMC FACTS
[6]  
Boston University Medical Center, 2019, GME DIV INCL COMM CO
[7]  
Centers for Disease Control and Prevention, 2014, OP GUID AC CAR HOSP
[8]  
Centers for Disease Control and Prevention, 2015, Guideline for prevention of catheter-associated urinary tract infections
[9]  
Centers for Medicare and Medicaid Services (CMS) HHS, 2011, Fed Regist, V76, P32816
[10]   Reduction in catheter-associated urinary tract infections by bundling interventions [J].
Clarke, Karen ;
Tong, David ;
Pan, Yi ;
Easley, Kirk A. ;
Norrick, Bonnie ;
Ko, Christin ;
Wang, Alan ;
Razavi, Behzad ;
Stein, Jason .
INTERNATIONAL JOURNAL FOR QUALITY IN HEALTH CARE, 2013, 25 (01) :43-49