Photoacoustic measurement of lutein in biological matrix

被引:5
作者
Bicanic, D
Luterotti, S
Becucci, M
Fogliano, V
Versloot, P
机构
[1] Wageningen Univ, Dept Agrotechnol & Food Sci, Div Biophys, Laser Lab Photothermal Sci, NL-6703 HA Wageningen, Netherlands
[2] Univ Zagreb, Fac Pharm & Biochem, Zagreb 10000, Croatia
[3] Univ Florence, European Lab Nonlinear Spectroscopy, LENS, Sesto Fiorentino, Italy
[4] Univ Naples Federico II, Dipartimento Sci Alimenti, I-80055 Portici, Italy
[5] Wageningen Univ, Dept Agrotechnol & Food Sci, Div Human Nutr, NL-6703 HD Wageningen, Netherlands
来源
JOURNAL DE PHYSIQUE IV | 2005年 / 125卷
关键词
D O I
10.1051/jp4:2005125190
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Photoacoustic (PA) spectroscopy was applied for the first time to quantify lutein in a complex biological matrix. Standard addition of lutein to a biological low-lutein matrix was used for the calibration. The PA signal was found linearly proportional (R > 0.98) to lutein concentration up to 0.3% (w/w). The dynamic range of concentrations extends to 1% (w/w) lutein. For a given experimental set-up the responsivity of PA detector within the range of linearity was estimated to 1.1 mV/1% lutein. Precision of repeated analyses is good with average RSD values of 4 and 5% for blanks and spiked samples, respectively. The analytical parameters indicate that the PA method is fast and sensitive enough for quantification of lutein in supplementary drugs and in the lutein-rich foods.
引用
收藏
页码:825 / 828
页数:4
相关论文
共 17 条
[1]   Rapid, accurate, and direct determination of total lycopene content in tomato paste [J].
Bicanic, D ;
Anese, M ;
Luterotti, S ;
Dadarlat, D ;
Gibkes, J ;
Lubbers, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (01) :687-689
[2]  
BICANIC D, UNPUB J AGR FOOD CHE
[3]  
BICANIC D, UNPUB J SCI FOOD AGR
[4]  
BICANIC D, IN PRESS ANAL CHEM
[5]  
BICANIC D, UNPUB J FOOD SCI
[6]  
CHERYAN M, 2003, COMMUNICATION
[7]   Identification and quantification of carotenoids including geometrical isomers in fruit and vegetable juices by liquid chromatography with ultraviolet-diode array detection [J].
Cortés, C ;
Esteve, MJ ;
Frígola, A ;
Torregrosa, F .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2004, 52 (08) :2203-2212
[8]   Determination of trans-β-carotene and other carotenoids in blood plasma using high-performance liquid chromatography and thermal lens detection [J].
Franko, M ;
van de Bovenkamp, P ;
Bicanic, D .
JOURNAL OF CHROMATOGRAPHY B, 1998, 718 (01) :47-54
[9]   SERUM ANTIOXIDANT VITAMINS AND RISK OF CATARACT [J].
KNEKT, P ;
HELIOVAARA, M ;
RISSANEN, A ;
AROMAA, A ;
AARAN, RK .
BMJ-BRITISH MEDICAL JOURNAL, 1992, 305 (6866) :1392-1394
[10]   Ultratraces of carotenes in tomato purees: HPLC-TLS study [J].
Luterotti, S ;
Markovic, K ;
Franko, M ;
Bicanic, D ;
Vahcic, N ;
Doka, O .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (01) :684-686