Effect of Safety Measures on Bacterial Contamination Rates of Blood Components in Germany

被引:10
|
作者
Walther-Wenke, Gabriele [1 ]
Daeubener, Walter [2 ]
Heiden, Margarethe [3 ]
Hoch, Jochen [4 ]
Hornei, Britt [5 ]
Volkers, Peter [3 ]
von Koenig, Carl Heinz Wirsing [6 ]
机构
[1] DRK Blutspendedienst W, Zentrum Transfus Med Munster, D-48151 Munster, Germany
[2] Univ Dusseldorf, Inst Med Mikrobiol & Krankenhaushyg, D-4000 Dusseldorf, Germany
[3] Paul Ehrlich Inst, Bundesinst Impfstoffe & Biomed Arzneimittel, D-6070 Langen, Germany
[4] Univ Klinikum Bonn, Inst Expt Hamatol & Transfus Med, Bonn, Germany
[5] MVZ Synlab Leverkusen GmbH, Bonn, Germany
[6] Helios Klinikum Krefeld, Inst Hyg & Lab Med, Krefeld, Germany
关键词
Bacterial contamination; Blood components; Contamination rate; Quality control; DONOR-ARM DISINFECTION; AMERICAN-RED-CROSS; APHERESIS PLATELETS; RESIDUAL RISK; DIVERSION; TRANSFUSION; EXPERIENCE; REDUCTION; SEPSIS; GROWTH;
D O I
10.1159/000330417
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Requirements for bacterial testing of blood components on a defined quantity as part of routine quality control were introduced in Germany by the National Advisory Committee Blood of the German Federal Ministry of Health in 1997. The philosophy was to establish standardized methods for bacterial testing. Numerous measures to reduce the risk of bacterial contamination were implemented into the blood donation and manufacturing processes between 1999 and 2002. German Blood establishments performed culture-based bacterial testing on random samples of platelet concentrates (PCs), red blood cells (RBCs) and fresh frozen plasma (FFP) and reported data out of the production periods 1998, 2001 and 2005/2006. While the bacterial contamination rate of apheresis PCs remained nearly unchanged, it decreased by 70% for pooled PCs to a rate of 0.158% in the last observation period. Leukocyte-depleted RBCs with diversion of the initial blood volume showed a contamination rate of 0.029% which is significantly lower than that of RBCs without leukocyte depletion and diversion (0.157%). The contamination rate of plasma decreased by 80%. Preventive measures resulted in a significant reduction of bacterial contamination of blood components. Long-term monitoring with standardized methods for bacteria testing supports evaluation of the cumulative effect of contamination reducing measures.
引用
收藏
页码:231 / 235
页数:5
相关论文
共 50 条
  • [41] Hepatitis B virus Blood Screening: Need for Reappraisal of Blood Safety Measures?
    Candotti, Daniel
    Laperche, Syria
    FRONTIERS IN MEDICINE, 2018, 5
  • [42] Bacterial contamination of platelet components: potential solutions to prevent transfusion-related sepsis
    Corash, Laurence
    EXPERT REVIEW OF HEMATOLOGY, 2011, 4 (05) : 509 - 525
  • [43] Effect of handwashing agents on bacterial contamination
    Anuradha P.
    Yasoda Devi P.
    Shiva Prakash M.
    The Indian Journal of Pediatrics, 1999, 66 (1) : 7 - 10
  • [44] Prevalence of bacterial contamination in blood and blood products at the National Blood Service Zimbabwe
    Makuni, Ngonidzashe
    Simango, Clifford
    Mavenyengwa, Rooyen T.
    JOURNAL OF INFECTION IN DEVELOPING COUNTRIES, 2015, 9 (04): : 421 - 424
  • [45] Bacterial contamination of platelet concentrates prepared by different methods:: results of standardized sterility testing in Germany
    Walther-Wenke, G
    Doerner, R
    Montag, T
    Greiss, O
    Hornei, B
    Knels, R
    Strobel, J
    Volkers, P
    Däubener, W
    VOX SANGUINIS, 2006, 90 (03) : 177 - 182
  • [46] The impact of overcrowding on the bacterial contamination of blood cultures in the ED
    Lee, Ching-Chi
    Lee, Nan-Yao
    Chuang, Ming-Che
    Chen, Po-Lin
    Chang, Chia-Ming
    Ko, Wen-Chien
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2012, 30 (06) : 839 - 845
  • [47] Bacterial contamination of peripheral blood progenitor cells for transplantation
    Jestice, HK
    Farrington, M
    Hunt, C
    Matthews, I
    Scott, MA
    Foreman, J
    Marcus, RE
    TRANSFUSION MEDICINE, 1996, 6 (02) : 103 - 110
  • [48] Quality assurance in postoperative autologous blood collection: Effect of collection period on risk of bacterial contamination of suction drainage blood
    Bauermann, E
    Eckermann, M
    Linde, L
    INFUSIONSTHERAPIE UND TRANSFUSIONSMEDIZIN, 1998, 25 (04): : 260 - 266
  • [49] The problem of bacterial contamination of reinfused blood spilled during surgery for juvenile nasal angiofibroma
    Nersesyan, M. V.
    Lubnin, A. Yu.
    Sazykina, S. Yu.
    Kapitanov, D. N.
    Moshkin, A. V.
    Aleksandrova, I. A.
    GEMATOLOGIYA I TRANSFUZIOLOGIYA, 2018, 63 (01): : 71 - 77
  • [50] The role of covering gowns in reducing rates of bacterial contamination of scrub suits
    Kaplan, C
    Mendiola, R
    Ndjatou, V
    Chapnick, E
    Minkoff, H
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2003, 188 (05) : 1154 - 1155