Both selective and nonselective His bundle, but not myocardial, pacing preserve ventricular electrical synchrony assessed by ultra-high-frequency ECG

被引:32
作者
Curila, Karol [1 ,2 ]
Prochazkova, Radka [1 ,2 ]
Jurak, Pavel [3 ]
Jastrzebski, Marek [4 ]
Halamek, Josef [3 ]
Moskal, Pawel [4 ]
Stros, Petr [1 ,2 ]
Vesela, Jana [1 ,2 ]
Waldauf, Petr [2 ,5 ]
Viscor, Ivo [3 ]
Plesinger, Filip [3 ]
Sussenbek, Ondrej [1 ,2 ]
Herman, Dalibor [1 ,2 ]
Osmancik, Pavel [1 ,2 ]
Smisek, Radovan [3 ]
Leinveber, Pavel [6 ]
Czarnecka, Danuta [4 ]
Widimsky, Petr [1 ,2 ]
机构
[1] Charles Univ Prague, Fac Med 3, Cardioctr, Srobarova 50, Prague 10034, Czech Republic
[2] Univ Hosp Kralovske Vinohrady, Prague, Czech Republic
[3] Czech Acad Sci, Inst Sci Instruments, Brno, Czech Republic
[4] Jagiellonian Univ, Dept Cardiol Intervent Electrocardiol & Hypertens, Med Coll, Krakow, Poland
[5] Charles Univ Prague, Dept Anesthesia & Intens Care, Prague, Czech Republic
[6] St Annes Univ Hosp, Int Clin Res Ctr, Brno, Czech Republic
关键词
Electrical dyssynchrony; His bundle; Myocardial; Pacing; Ultra-high-frequency ECG; OUTCOMES;
D O I
10.1016/j.hrthm.2019.11.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Right ventricular myocardial pacing leads to nonphysiological activation of heart ventricles. Contrary to this, His bundle pacing preserves their fast activation. Ultra-high-frequency electrocardiography (UHF-ECG) is a novel tool for ventricular depolarization assessment. OBJECTIVE The purpose of this study was to describe UHF-ECG depolarization patterns during myocardial and His bundle pacing. METHODS Forty-six patients undergoing His bundle pacing to treat bradycardia and spontaneous QRS complexes without bundle branch block were included. UHF-ECG recordings were performed during spontaneous rhythm, pure myocardial para-Hisian capture, and His bundle capture. QRS duration, QRS area, depolarization time in specific leads, and the UHF-ECG-derived ventricular dyssynchrony index were calculated. RESULTS One hundred thirty-three UHF-ECG recordings were performed in 46 patients (44 spontaneous rhythm, 28 selective His bundle, 43 nonselective His bundle, and 18 myocardial capture). The mean QRS duration was 117 ms for spontaneous rhythm, 118 ms for selective, 135 ms for nonselective, and 166 ms for myocardial capture (P < .001 for nonselective and myocardial capture compared to each of the other types of ventricular activation). The calculated dyssynchrony index was shortest during spontaneous rhythm (12 ms; P = .02 compared to selective and P = .09 compared to nonselective), and it did not differ between selective and nonselective His bundle capture (16 vs 15 ms; P > .99) and was longest during myocardial capture of the para-Hisian area (37 ms; P < .001 compared to each of the other types of ventricular activation). CONCLUSION In patients without bundle branch block, both types of His bundle, but not myocardial, capture preserve ventricular electrical synchrony as measured using UHF-ECG.
引用
收藏
页码:607 / 614
页数:8
相关论文
共 19 条
  • [1] Abdelrahman M, 2018, J AM COLL CARDIOL, V71, P2581, DOI [10.1016/j.jacc.2018.02.048, 10.1016/S0735-1097(18)33122-X]
  • [2] [Anonymous], HEART RHYTHM
  • [3] [Anonymous], 2019, LANG ENV STAT COMP
  • [4] Fitting Linear Mixed-Effects Models Using lme4
    Bates, Douglas
    Maechler, Martin
    Bolker, Benjamin M.
    Walker, Steven C.
    [J]. JOURNAL OF STATISTICAL SOFTWARE, 2015, 67 (01): : 1 - 48
  • [5] Clinical Outcomes of Selective Versus Nonselective His Bundle Pacing
    Beer, Dominik
    Sharma, Parikshit S.
    Subzposh, Faiz A.
    Naperkowski, Angela
    Pietrasik, Grzegorz M.
    Durr, Brendan
    Qureshi, Maria
    Panikkath, Ragesh
    Abdelrahman, Mohamed
    Williams, Brent A.
    Hanifin, Jillian L.
    Zimberg, Ryan
    Austin, Kelly
    Macuch, Brooke
    Trohman, Richard G.
    Vanenkevort, Erin A.
    Dandamudi, Gopi
    Vijayaraman, Pugazhendhi
    [J]. JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (07) : 766 - 774
  • [6] Severe left ventricular dysfunction in infants with ventricular preexcitation
    Cadrin-Tourigny, Julia
    Fournier, Anne
    Andelfinger, Gregor
    Khairy, Paul
    [J]. HEART RHYTHM, 2008, 5 (09) : 1320 - 1322
  • [7] Permanent direct his bundle pacing does not induce ventricular dyssynchrony unlike conventional right ventricular apical pacing - An intrapatient acute comparison study
    Catanzariti, Domenico
    Maines, Massimiliano
    Cemin, Claudio
    Broso, Gianpaolo
    Marotta, Tiziana
    Vergara, Giuseppe
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2006, 16 (02) : 81 - 92
  • [8] The relationship between ECG predictors of cardiac resynchronization therapy benefit
    Halamek, Josef
    Leinveber, Pavel
    Viscor, Ivo
    Smisek, Radovan
    Plesinger, Filip
    Vondra, Vlastimil
    Lipoldova, Jolene
    Matejkova, Magdalena
    Jurak, Pavel
    [J]. PLOS ONE, 2019, 14 (05):
  • [9] His bundle has a shorter chronaxie than does the adjacent ventricular myocardium: Implications for pacemaker programming
    Jastrzebski, Marek
    Moskal, Pawe
    Bednarek, Agnieszka
    Kiebasa, Grzegorz
    Vijayaraman, Pugazhendhi
    Czarnecka, Danuta
    [J]. HEART RHYTHM, 2019, 16 (12) : 1808 - 1816
  • [10] Acute Mechanical Effect of Right Ventricular Pacing at Different Sites Using Velocity Vector Imaging
    Ji, Ling
    Hu, Wenzhi
    Yao, Jing
    Yu, Jian
    Chen, Chun
    Yong, Yonghong
    Zhou, Lei
    Xu, Di
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2010, 27 (10): : 1219 - 1227