Both selective and nonselective His bundle, but not myocardial, pacing preserve ventricular electrical synchrony assessed by ultra-high-frequency ECG

被引:35
作者
Curila, Karol [1 ,2 ]
Prochazkova, Radka [1 ,2 ]
Jurak, Pavel [3 ]
Jastrzebski, Marek [4 ]
Halamek, Josef [3 ]
Moskal, Pawel [4 ]
Stros, Petr [1 ,2 ]
Vesela, Jana [1 ,2 ]
Waldauf, Petr [2 ,5 ]
Viscor, Ivo [3 ]
Plesinger, Filip [3 ]
Sussenbek, Ondrej [1 ,2 ]
Herman, Dalibor [1 ,2 ]
Osmancik, Pavel [1 ,2 ]
Smisek, Radovan [3 ]
Leinveber, Pavel [6 ]
Czarnecka, Danuta [4 ]
Widimsky, Petr [1 ,2 ]
机构
[1] Charles Univ Prague, Fac Med 3, Cardioctr, Srobarova 50, Prague 10034, Czech Republic
[2] Univ Hosp Kralovske Vinohrady, Prague, Czech Republic
[3] Czech Acad Sci, Inst Sci Instruments, Brno, Czech Republic
[4] Jagiellonian Univ, Dept Cardiol Intervent Electrocardiol & Hypertens, Med Coll, Krakow, Poland
[5] Charles Univ Prague, Dept Anesthesia & Intens Care, Prague, Czech Republic
[6] St Annes Univ Hosp, Int Clin Res Ctr, Brno, Czech Republic
关键词
Electrical dyssynchrony; His bundle; Myocardial; Pacing; Ultra-high-frequency ECG; OUTCOMES;
D O I
10.1016/j.hrthm.2019.11.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Right ventricular myocardial pacing leads to nonphysiological activation of heart ventricles. Contrary to this, His bundle pacing preserves their fast activation. Ultra-high-frequency electrocardiography (UHF-ECG) is a novel tool for ventricular depolarization assessment. OBJECTIVE The purpose of this study was to describe UHF-ECG depolarization patterns during myocardial and His bundle pacing. METHODS Forty-six patients undergoing His bundle pacing to treat bradycardia and spontaneous QRS complexes without bundle branch block were included. UHF-ECG recordings were performed during spontaneous rhythm, pure myocardial para-Hisian capture, and His bundle capture. QRS duration, QRS area, depolarization time in specific leads, and the UHF-ECG-derived ventricular dyssynchrony index were calculated. RESULTS One hundred thirty-three UHF-ECG recordings were performed in 46 patients (44 spontaneous rhythm, 28 selective His bundle, 43 nonselective His bundle, and 18 myocardial capture). The mean QRS duration was 117 ms for spontaneous rhythm, 118 ms for selective, 135 ms for nonselective, and 166 ms for myocardial capture (P < .001 for nonselective and myocardial capture compared to each of the other types of ventricular activation). The calculated dyssynchrony index was shortest during spontaneous rhythm (12 ms; P = .02 compared to selective and P = .09 compared to nonselective), and it did not differ between selective and nonselective His bundle capture (16 vs 15 ms; P > .99) and was longest during myocardial capture of the para-Hisian area (37 ms; P < .001 compared to each of the other types of ventricular activation). CONCLUSION In patients without bundle branch block, both types of His bundle, but not myocardial, capture preserve ventricular electrical synchrony as measured using UHF-ECG.
引用
收藏
页码:607 / 614
页数:8
相关论文
共 19 条
[1]  
Abdelrahman M, 2018, J AM COLL CARDIOL, V71, P2581, DOI [10.1016/j.jacc.2018.02.048, 10.1016/S0735-1097(18)33122-X]
[2]  
[Anonymous], HEART RHYTHM
[3]  
[Anonymous], 2015, Integrated development environment for R
[4]   Fitting Linear Mixed-Effects Models Using lme4 [J].
Bates, Douglas ;
Maechler, Martin ;
Bolker, Benjamin M. ;
Walker, Steven C. .
JOURNAL OF STATISTICAL SOFTWARE, 2015, 67 (01) :1-48
[5]   Clinical Outcomes of Selective Versus Nonselective His Bundle Pacing [J].
Beer, Dominik ;
Sharma, Parikshit S. ;
Subzposh, Faiz A. ;
Naperkowski, Angela ;
Pietrasik, Grzegorz M. ;
Durr, Brendan ;
Qureshi, Maria ;
Panikkath, Ragesh ;
Abdelrahman, Mohamed ;
Williams, Brent A. ;
Hanifin, Jillian L. ;
Zimberg, Ryan ;
Austin, Kelly ;
Macuch, Brooke ;
Trohman, Richard G. ;
Vanenkevort, Erin A. ;
Dandamudi, Gopi ;
Vijayaraman, Pugazhendhi .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (07) :766-774
[6]   Severe left ventricular dysfunction in infants with ventricular preexcitation [J].
Cadrin-Tourigny, Julia ;
Fournier, Anne ;
Andelfinger, Gregor ;
Khairy, Paul .
HEART RHYTHM, 2008, 5 (09) :1320-1322
[7]   Permanent direct his bundle pacing does not induce ventricular dyssynchrony unlike conventional right ventricular apical pacing - An intrapatient acute comparison study [J].
Catanzariti, Domenico ;
Maines, Massimiliano ;
Cemin, Claudio ;
Broso, Gianpaolo ;
Marotta, Tiziana ;
Vergara, Giuseppe .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2006, 16 (02) :81-92
[8]   The relationship between ECG predictors of cardiac resynchronization therapy benefit [J].
Halamek, Josef ;
Leinveber, Pavel ;
Viscor, Ivo ;
Smisek, Radovan ;
Plesinger, Filip ;
Vondra, Vlastimil ;
Lipoldova, Jolene ;
Matejkova, Magdalena ;
Jurak, Pavel .
PLOS ONE, 2019, 14 (05)
[9]   His bundle has a shorter chronaxie than does the adjacent ventricular myocardium: Implications for pacemaker programming [J].
Jastrzebski, Marek ;
Moskal, Pawe ;
Bednarek, Agnieszka ;
Kiebasa, Grzegorz ;
Vijayaraman, Pugazhendhi ;
Czarnecka, Danuta .
HEART RHYTHM, 2019, 16 (12) :1808-1816
[10]   Acute Mechanical Effect of Right Ventricular Pacing at Different Sites Using Velocity Vector Imaging [J].
Ji, Ling ;
Hu, Wenzhi ;
Yao, Jing ;
Yu, Jian ;
Chen, Chun ;
Yong, Yonghong ;
Zhou, Lei ;
Xu, Di .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2010, 27 (10) :1219-1227