Aortoiliac occlusive disease in patients with known or suspected peripheral vascular disease: Safety and efficacy of gadofosveset-enhanced MR angiography - Multicenter comparative phase III study

被引:66
作者
Rapp, JH
Wolff, SD
Quinn, SF
Soto, JA
Meranze, SG
Muluk, S
Blebea, J
Johnson, SP
Rofsky, NM
Duerinckx, A
Foster, GS
Kent, KC
Moneta, G
Middlebrook, MR
Narra, VR
Toombs, BD
Pollak, J
Yucel, EK
Shamsi, K
Weisskoff, RM
机构
[1] San Francisco DVA Med Ctr, Surg Serv, San Francisco, CA 94121 USA
[2] Lenox Hill Hosp, New York, NY 10021 USA
[3] Oregon Imaging, Eugene, OR USA
[4] Ctr Comercial Almactr, Medellin, Colombia
[5] Vanderbilt Univ, Ctr Med, Nashville, TN USA
[6] Univ Pittsburgh, Ctr Med, Pittsburgh, PA USA
[7] Temple Univ, Philadelphia, PA 19122 USA
[8] Univ Colorado, Ctr Hlth Sci, Denver, CO 80202 USA
[9] Beth Israel Deaconess Med Ctr, Boston, MA 02215 USA
[10] Dept Vet Affairs, N Hlth Care Syst, Dallas, TX USA
[11] Rush Presbyterian St Lukes Med Ctr, Chicago, IL 60612 USA
[12] Cornell Univ, New York Hosp, Ctr Med, New York, NY USA
[13] Oregon Hlth Sci Univ, Portland, OR 97201 USA
[14] Univ Texas, Hlth Sci Ctr Hosp, Houston, TX USA
[15] Barnes Jewish Hosp, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
[16] St Lukes Episcopal Hosp, Texas Heart Ctr, Houston, TX 77030 USA
[17] Yale Univ, Sch Med, New Haven, CT USA
[18] Brigham & Womens Hosp, Boston, MA 02115 USA
[19] Berlex Labs Inc, Montville, NJ USA
[20] EPIX Pharmaceut, Cambridge, MA USA
关键词
D O I
10.1148/radiol.2361040148
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively determine the safety and efficacy of the gadolinium-based blood pool magnetic resonance (MR) imaging contrast agent gadofosveset in patients known to have or suspected of having peripheral vascular disease. MATERIALS AND METHODS: Ethical committee approval and patient written informed consent were obtained. This study was compliant with the Health Insurance Portability and Accountability Act. Adults known or suspected to have peripheral vascular disease received gadofosveset (0.03 mmol per kilogram of body weight) for MR angiography of the aortoiliac region. Gadofosveset-enhanced MR angiography and unenhanced two-dimensional time-of-flight MR angiography were compared with the reference standard, conventional angiography, for the presence of vascular stenosis. All patients were monitored for adverse events with hematologic analysis, analysis of blood chemistry, urinalysis, and electrocardiographic parameters; these methods were analyzed to determine safety. RESULTS: A total of 274 patients were enrolled at 37 centers. Gadofosveset-enhanced MR angiography showed significant improvement (P <.001) compared with unenhanced MR angiography for each of the readers for diagnosis of clinically significant (>= 50%) stenosis. Specificity and accuracy were significantly greater for three readers, and sensitivity increased significantly for two readers. For all readers the area under the receiver operator characteristic curve for both quantitative and qualitative measures of significant disease increased (P <.001) for gadofosveset-enhanced MR angiography versus two-dimensional time-of-flight MR angiography. All readers also expressed more confidence in diagnosis (P <.001) and found fewer images to be uninterpretable (0.5% vs 11.0%). The most common adverse events were as follows: feeling hot, 12 (4.4%) patients; nausea, 10 (3.6%) patients; headache, nine (3.3%) patients; and burning sensation, eight (2.9%) patients. Only four serious adverse events were reported, in three patients, and all events were rated as unlikely related to the drug. No patients were excluded because of adverse events or laboratory abnormalities. There were no clinically important trends in the findings of hematologic analysis, blood chemistry, urinalysis, electrocardiography, or physical examination. CONCLUSION: On the basis of substantial improvements over noncontrast MR angiography in efficacy and a minimal and transient side-effect profile, gadofosveset was found to be safe and effective for MR angiography in patients known or suspected to have peripheral vascular disease. ((c)) RSNA, 2005.
引用
收藏
页码:71 / 78
页数:8
相关论文
共 26 条
  • [11] Aorta and runoff vessels: Single-injection MR angiography with automated table movement compared with multiinjection time-resolved MR angiography - Initial results
    Hany, TF
    Carroll, TJ
    Omary, RA
    Eparza-Coss, E
    Korosec, FR
    Mistretta, CA
    Grist, TM
    [J]. RADIOLOGY, 2001, 221 (01) : 266 - 272
  • [12] A numerical study of magnetic resonance images of pulsatile flow in a two dimensional carotid bifurcation - A numerical study of MR images
    Jou, LD
    Saloner, D
    [J]. MEDICAL ENGINEERING & PHYSICS, 1998, 20 (09) : 643 - 652
  • [13] MS-325: Albumin-targeted contrast agent for MR angiography
    Lauffer, RB
    Parmelee, DJ
    Dunham, SU
    Ouellet, HS
    Dolan, RP
    Witte, S
    McMurry, TJ
    Walovitch, RC
    [J]. RADIOLOGY, 1998, 207 (02) : 529 - 538
  • [14] LAUFFER RB, 1996, ACAD RADIOL, V3, P356
  • [15] Preclinical evaluation of the pharmacokinetics, biodistribution, and elimination of MS-325, a blood pool agent for magnetic resonance imaging
    Parmelee, DJ
    Walovitch, RC
    Ouellet, HS
    Lauffer, RB
    [J]. INVESTIGATIVE RADIOLOGY, 1997, 32 (12) : 741 - 747
  • [16] MR angiography with gadofosveset trisodium for peripheral vascular disease: Phase II trial
    Perreault, P
    Edelman, MA
    Baum, RA
    Yucel, EK
    Weisskoff, RM
    Shamsi, K
    Mohler, ER
    [J]. RADIOLOGY, 2003, 229 (03) : 811 - 820
  • [17] Iliac artery stenosis measurements: Comparison of two-dimensional time-of-flight and three-dimensional dynamic gadolinium-enhanced MR angiography
    Poon, E
    Yucel, EK
    PaganMarin, H
    Kayne, H
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (04) : 1139 - 1144
  • [18] DYNAMIC GADOLINIUM-ENHANCED 3-DIMENSIONAL ABDOMINAL MR ARTERIOGRAPHY
    PRINCE, MR
    YUCEL, EK
    KAUFMAN, JA
    HARRISON, DC
    GELLER, SC
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (06): : 877 - 881
  • [19] Aortic and lower-extremity arterial disease: Evaluation with MR angiography versus conventional angiography
    Quinn, SF
    Sheley, RC
    Semonsen, KG
    Leonardo, VJ
    Kojima, K
    Szumowski, J
    [J]. RADIOLOGY, 1998, 206 (03) : 693 - 701
  • [20] Determinants of image appearance in contrast-enhanced magnetic resonance angiography - A review
    Saloner, D