Detection of Parathyroid Hormone Using an Electrochemical Impedance Biosensor Based on PAMAM Dendrimers

被引:26
|
作者
Ozcan, Hakki Mevlut [1 ]
Sezginturk, Mustafa Kemal [2 ]
机构
[1] Trakya Univ, Dept Chem, Fac Sci, Edirne, Turkey
[2] Namik Kemal Univ, Fac Arts & Sci, Dept Chem, Tekirdag, Turkey
关键词
parathyroid hormone; biosensor; PAMAM; electrochemical impedance spectroscopy; 12-mercapto dodecanoic; PRIMARY HYPERPARATHYROIDISM; MULTILAYER FILMS; GLANDS; IMMOBILIZATION; SPECTROSCOPY; IMMUNOASSAY; CALCIUM; SENSORS;
D O I
10.1002/btpr.2060
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
This paper presents a novel hormone-based impedimetric biosensor to determine parathyroid hormone (PTH) level in serum for diagnosis and monitoring treatment of hyperparathyroidism, hypoparathyroidism and thyroid cancer. The interaction between PTH and the biosensor was investigated by an electrochemical method. The biosensor was based on the gold electrode modified by 12-mercapto dodecanoic (12MDDA). Antiparathyroid hormone (anti-PTH) was covalently immobilized on to poly amidoamine dendrimer (PAMAM) which was bound to a 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide/N-hydroxysuccinimide (EDC/NHS) couple, self-assembled monolayer structure from one of the other NH2 sites. The immobilization of anti-PTH was monitored by electrochemical impedance spectroscopy, cyclic voltammetry and scanning electron microscope techniques. After the optimization studies of immobilization materials such as 12MDDA, EDC-NHS, PAMAM, and glutaraldehyde, the performance of the biosensor was investigated in terms of linearity, sensitivity, repeatability, and reproducibility. PTH was detected within a linear range of 10-60 fg/mL. Finally the described biosensor was used to monitor PTH levels in artificial serum samples. (C) 2015 American Institute of Chemical Engineers
引用
收藏
页码:815 / 822
页数:8
相关论文
共 50 条
  • [11] Study on a nano-porous gold/polyamidoamine (NPG/PAMAM)-based electrochemical aptamer biosensor for the detection of ochratoxin a in the red wine
    Wensi, Zhang
    Chuanjin, Cui
    Chen, Hongshuo
    Xuechao, Zhang
    Junhui, Du
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2023, 40 (08): : 1059 - 1073
  • [12] An ultrasensitive electrochemical impedance-based biosensor using insect odorant receptors to detect odorants
    Khadka, Roshan
    Aydemir, Nihan
    Carraher, Colm
    Hamiaux, Cyril
    Colbert, Damon
    Cheema, Jamal
    Malmstrom, Jenny
    Kralicek, Andrew
    Travas-Sejdic, Jadranka
    BIOSENSORS & BIOELECTRONICS, 2019, 126 : 207 - 213
  • [13] Electrochemical Impedance Spectroscopy-Based Microfluidic Biosensor Using Cell-Imprinted Polymers for Bacteria Detection
    Akhtarian, Shiva
    Brar, Satinder Kaur
    Rezai, Pouya
    BIOSENSORS-BASEL, 2024, 14 (09):
  • [14] Ultrasensitive detection of fibrinogen using erythrocyte membrane-draped electrochemical impedance biosensor
    Park, Joohyung
    Lee, Wonseok
    Kim, Insu
    Kim, Minwoo
    Jo, Seongjae
    Kim, Woong
    Park, Hyunjun
    Lee, Gyudo
    Choi, Wonjoon
    Yoon, Dae Sung
    Park, Jinsung
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 293 : 296 - 303
  • [15] A bacteriophage endolysin-based electrochemical impedance biosensor for the rapid detection of Listeria cells
    Tolba, Mona
    Ahmed, Minhaz Uddin
    Tlili, Chaker
    Eichenseher, Fritz
    Loessner, Martin J.
    Zourob, Mohammed
    ANALYST, 2012, 137 (24) : 5749 - 5756
  • [16] A novel electrochemical impedance biosensor based on plasma-polymerized films for detection of biotin
    Deng, Ting
    Cao, Zhong
    Shen, Guoli
    ADVANCED MATERIALS, PTS 1-4, 2011, 239-242 : 1653 - +
  • [17] A new immobilization procedure for development of an electrochemical immunosensor for parathyroid hormone detection based on gold electrodes modified with 6-mercaptohexanol and silane
    Simsek, Cigdem Sayikli
    Karaboga, Munteha Nur Sonuc
    Sezginturk, Mustafa Kemal
    TALANTA, 2015, 144 : 210 - 218
  • [18] Electrochemical biosensor based on biomimetic material for myoglobin detection
    Moreira, Felisrnina T. C.
    Dutra, Rosa A. F.
    Noronha, Joao P. C.
    Sales, M. Goreti F.
    ELECTROCHIMICA ACTA, 2013, 107 : 481 - 487
  • [19] Detection and discrimination of alpha-fetoprotein with a label-free electrochemical impedance spectroscopy biosensor array based on lectin functionalized carbon nanotubes
    Yang, Haiying
    Li, Zhejian
    Wei, Xiaomin
    Huang, Ru
    Qi, Honglan
    Gao, Qiang
    Li, Chenzhong
    Zhang, Chengxiao
    TALANTA, 2013, 111 : 62 - 68
  • [20] Impedance Based Biosensor for Agricultural Pathogen Detection
    Patel, Rhea
    Vinchurkar, Madhuri
    Patkar, Rajul
    Pranjale, Gopal
    Baghini, Maryam Shojaei
    2021 IEEE 21ST INTERNATIONAL CONFERENCE ON NANOTECHNOLOGY (IEEE NANO 2021), 2021, : 385 - 388