The level of detail required in a deformable phantom to accurately perform quality assurance of deformable image registration

被引:7
作者
Saenz, Daniel L. [1 ]
Kim, Hojin [2 ]
Chen, Josephine [2 ]
Stathakis, Sotirios [1 ]
Kirby, Neil [1 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, San Antonio, TX 78229 USA
[2] Univ Calif San Francisco, San Francisco, CA 94143 USA
关键词
deformable image registration; quality assurance; deformable phantoms; CT; RADIOTHERAPY; ALGORITHM;
D O I
10.1088/0031-9155/61/17/6269
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The primary purpose of the study was to determine how detailed deformable image registration (DIR) phantoms need to adequately simulate human anatomy and accurately assess the quality of DIR algorithms. In particular, how many distinct tissues are required in a phantom to simulate complex human anatomy? Pelvis and head-and-neck patient CT images were used for this study as virtual phantoms. Two data sets from each site were analyzed. The virtual phantoms were warped to create two pairs consisting of undeformed and deformed images. Otsu's method was employed to create additional segmented image pairs of n distinct soft tissue CT number ranges (fat, muscle, etc). A realistic noise image was added to each image. Deformations were applied in MIM Software (MIM) and Velocity deformable multi-pass (DMP) and compared with the known warping. Images with more simulated tissue levels exhibit more contrast, enabling more accurate results. Deformation error (magnitude of the vector difference between known and predicted deformation) was used as a metric to evaluate how many CT number gray levels are needed for a phantom to serve as a realistic patient proxy. Stabilization of the mean deformation error was reached by three soft tissue levels for Velocity DMP and MIM, though MIM exhibited a persisting difference in accuracy between the discrete images and the unprocessed image pair. A minimum detail of three levels allows a realistic patient proxy for use with Velocity and MIM deformation algorithms.
引用
收藏
页码:6269 / 6280
页数:12
相关论文
共 18 条
  • [1] Left ventricle volume measurements in cardiac micro-CT: The impact of radiation dose and contrast agent
    Badea, Cristian T.
    Wetzel, Arthur W.
    Mistry, Nilesh
    Pomerantz, Stuart
    Nave, Demian
    Johnson, G. Allan
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2008, 32 (03) : 239 - 250
  • [2] Comparison of 12 deformable registration strategies in adaptive radiation therapy for the treatment of head and neck tumors
    Castadot, Pierre
    Lee, John Aldo
    Parraga, Adriane
    Geets, Xavier
    Macq, Benoit
    Gregoire, Vincent
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 89 (01) : 1 - 12
  • [3] A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets
    Castillo, Richard
    Castillo, Edward
    Guerra, Rudy
    Johnson, Valen E.
    McPhail, Travis
    Garg, Amit K.
    Guerrero, Thomas
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (07) : 1849 - 1870
  • [4] Development of a deformable lung phantom for the evaluation of deformable registration
    Chang, Jina
    Suh, Tae-Suk
    Lee, Dong-Soo
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (01): : 281 - 286
  • [5] Implementation and evaluation of various demons deformable image registration algorithms on a GPU
    Gu, Xuejun
    Pan, Hubert
    Liang, Yun
    Castillo, Richard
    Yang, Deshan
    Choi, Dongju
    Castillo, Edward
    Majumdar, Amitava
    Guerrero, Thomas
    Jiang, Steve B.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (01) : 207 - 219
  • [6] Intrathoracic tumour motion estimation from CT imaging using the 3D optical flow method
    Guerrero, T
    Zhang, G
    Huang, TC
    Lin, KP
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (17) : 4147 - 4161
  • [7] Quantification of accuracy of the automated nonlinear image matching and anatomical labeling (ANIMAL) nonlinear registration algorithm for 4D CT images of lung
    Heath, E.
    Collins, D. L.
    Keall, P. J.
    Dong, L.
    Seuntjens, J.
    [J]. MEDICAL PHYSICS, 2007, 34 (11) : 4409 - 4421
  • [8] Kaiping Wei, 2007, 2007 1st International Conference on Bioinformatics and Biomedical Engineering, P717
  • [9] Objective assessment of deformable image registration in radiotherapy: A multi-institution study
    Kashani, Rojano
    Hub, Martina
    Balter, James M.
    Kessler, Marc L.
    Dong, Lei
    Zhang, Lifei
    Xing, Lei
    Xie, Yaoqin
    Hawkes, David
    Schnabel, Julia A.
    McClelland, Jamie
    Joshi, Sarang
    Chen, Quan
    Lu, Weiguo
    [J]. MEDICAL PHYSICS, 2008, 35 (12) : 5944 - 5953
  • [10] The need for application-based adaptation of deformable image registration
    Kirby, Neil
    Chuang, Cynthia
    Ueda, Utako
    Pouliot, Jean
    [J]. MEDICAL PHYSICS, 2013, 40 (01)