Advances in rapid detection of SARS-CoV-2 by mass spectrometry

被引:13
作者
Wong, Tsz-Fung [1 ,2 ,3 ,4 ,5 ,6 ]
So, Pui-Kin [1 ,2 ,3 ,4 ,5 ,6 ]
Yao, Zhong-Ping [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Hong Kong Polytech Univ, State Key Lab Chem Biol & Drug Discovery, Hung Hom,Kowloon, Hong Kong, Peoples R China
[2] Hong Kong Polytech Univ, Dept Appl Biol & Chem Technol, Hung Hom,Kowloon, Hong Kong, Peoples R China
[3] Hong Kong Polytech Univ, Res Inst Future Food, Hung Hom,Kowloon, Hong Kong, Peoples R China
[4] Hong Kong Polytech Univ, Res Ctr Chinese Med Innovat, Hung Hom,Kowloon, Hong Kong, Peoples R China
[5] Hong Kong Polytech Univ, State Key Lab Chinese Med & Mol Pharmacol Incubat, Shenzhen Res Inst, Shenzhen 518057, Peoples R China
[6] Hong Kong Polytech Univ, Shenzhen Key Lab Food Biol Safety Control, Shenzhen Res Inst, Shenzhen 518057, Peoples R China
关键词
SARS-CoV-2; Mass spectrometry; Proteomics; MALDI; On -site detection; EXHALED BREATH; PROTEOMICS; IDENTIFICATION; IONIZATION; SAMPLES; SYSTEM; ASSAY; MS;
D O I
10.1016/j.trac.2022.116759
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
COVID-19 has already been lasting for more than two years and it has been severely affecting the whole world. Still, detection of SARS-CoV-2 remains the frontline approach to combat the pandemic, and the reverse transcription polymerase chain reaction (RT-PCR)-based method is the well recognized detection method for the enormous analytical demands. However, the RT-PCR method typically takes a relatively long time, and can produce false positive and false negative results. Mass spectrometry (MS) is a very commonly used technique with extraordinary sensitivity, specificity and speed, and can produce quali-tative and quantitative information of various analytes, which cannot be achieved by RT-PCR. Since the pandemic outbreak, various mass spectrometric approaches have been developed for rapid detection of SARS-CoV-2, including the LC-MS/MS approaches that could allow analysis of several hundred clinical samples per day with one MS system, MALDI-MS approaches that could directly analyze clinical samples for the detection, and efforts for the on-site detection with portable devices. In this review, these mass spectrometric approaches were summarized, and their pros and cons as well as further development were also discussed.(c) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 67 条
[1]   On-site detection of fentanyl and its derivatives by field portable nano-liquid chromatography-electron lonization-mass spectrometry (nLC-EI-MS) [J].
Abonamah, Jocelyn V. ;
Eckenrode, Brian A. ;
Moini, Mehdi .
FORENSIC CHEMISTRY, 2019, 16
[2]  
[Anonymous], US
[3]   Current methods for diagnosis of human coronaviruses: pros and cons [J].
Benzigar, Mercy R. ;
Bhattacharjee, Ripon ;
Baharfar, Mahroo ;
Liu, Guozhen .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (09) :2311-2330
[4]   Reproducible Breath Metabolite Changes in Children with SARS-CoV-2 Infection [J].
Berna, Amalia Z. ;
Akaho, Elikplim H. ;
Harris, Rebecca M. ;
Congdon, Morgan ;
Korn, Emilie ;
Neher, Samuel ;
M'Farrej, Mirna ;
Burns, Julianne ;
John, Audrey R. Odom .
ACS INFECTIOUS DISEASES, 2021, 7 (09) :2596-2603
[5]   Targeted proteomics as a tool to detect SARS-CoV-2 proteins in clinical specimens [J].
Bezstarosti, Karel ;
Lamers, Mart M. ;
Doff, Wouter A. S. ;
Wever, Peter C. ;
Thai, Khoa T. D. ;
van Kampen, Jeroen J. A. ;
Haagmans, Bart L. ;
Demmers, Jeroen A. A. .
PLOS ONE, 2021, 16 (11)
[6]   Mass Spectrometric Analysis of Urine from COVID-19 Patients for Detection of SARS-CoV-2 Viral Antigen and to Study Host Response [J].
Chavan, Sandip ;
Mangalaparthi, Kiran K. ;
Singh, Smrita ;
Renuse, Santosh ;
Vanderboom, Patrick M. ;
Madugundu, Anil Kumar ;
Budhraja, Rohit ;
McAulay, Kathrine ;
Grys, Thomas E. ;
Rule, Andrew D. ;
Alexander, Mariam P. ;
O'Horo, John C. ;
Badley, Andrew D. ;
Pandey, Akhilesh .
JOURNAL OF PROTEOME RESEARCH, 2021, 20 (07) :3404-3413
[7]   Towards an SI-Traceable Reference Measurement System for Seven Serum Apolipoproteins Using Bottom-Up Quantitative Proteomics: Conceptual Approach Enabled by Cross-Disciplinary/Cross-Sector Collaboration [J].
Cobbaert, Christa M. ;
Althaus, Harald ;
Brkovic, Ilijana Begcevic ;
Ceglarek, Uta ;
Coassin, Stefan ;
Delatour, Vincent ;
Deprez, Liesbet ;
Dikaios, Ioannis ;
Dittrich, Julia ;
Hoofnagle, Andrew N. ;
Kostner, Gerhard M. ;
Kronenberg, Florian ;
Kuklenyik, Zsusanna ;
Prinzing, Urban ;
Vesper, Hubert W. ;
Zegers, Ingrid ;
Ruhaak, L. Renee .
CLINICAL CHEMISTRY, 2021, 67 (03) :478-489
[8]  
Cornish TJ, 1999, J HOPKINS APL TECH D, V20, P335
[9]   Matrix-Assisted Ionization on a Portable Mass Spectrometer: Analysis Directly from Biological and Synthetic Materials [J].
Devereaux, Zachary J. ;
Reynolds, Christian A. ;
Fischer, Joshua L. ;
Foley, Casey D. ;
DeLeeuw, Jessica L. ;
Wager-Miller, James ;
Narayan, Srinivas B. ;
Mackie, Ken ;
Trimpin, Sarah .
ANALYTICAL CHEMISTRY, 2016, 88 (22) :10831-10836
[10]   Influenza A Virus Cell Entry, Replication, Virion Assembly and Movement [J].
Dou, Dan ;
Revol, Rebecca ;
Ostbye, Henrik ;
Wang, Hao ;
Daniels, Robert .
FRONTIERS IN IMMUNOLOGY, 2018, 9