Field Study on the Impact of Indoor Air Quality on Broiler Production

被引:8
|
作者
Zhang, Ge [1 ]
Zhang, Yinping [2 ]
Kim, Yoonshin [3 ]
Kim, Jungho [4 ]
Liu, Li
Yu, Xiang
Teng, Xiaoguo [2 ]
机构
[1] Univ Sci & Technol Beijing, Sch Civil & Environm Engn, Dept Bldg Environm & Equipment Engn, Beijing 100083, Peoples R China
[2] Tsinghua Univ, Sch Architecture, Dept Bldg Sci, Beijing 100084, Peoples R China
[3] Hanyang Univ, Inst Environm Ind Med, Seoul 133791, South Korea
[4] Samsung Elect, Digital Air Solut Business Team, Suwon 443742, South Korea
关键词
Air cleaning; Broiler; Indoor air quality; Mortality; Production; Ventilation; STOCKING DENSITY; AMBIENT-TEMPERATURES; BUILDING PATHOLOGY; RESPIRATORY HEALTH; GROWTH PROMOTERS; SICK BUILDINGS; ANIMAL HEALTH; CHICKENS; STRESS; HISTORY;
D O I
10.1177/1420326X11409468
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The presented research investigated the impact of indoor air quality on the production of broilers. Three broiler houses of different air quality environments with different controlled ventilation rates and uses of super plasma ionizing (SPI) air purifiers were investigated. The broilers were fed with antibiotic or non-antibiotic feeds to determine if the air quality control could be sufficient to keep broilers healthy without using antibiotics. The weight gain, mortality rate and serum cholesterol level of broilers were monitored as the benefit indicators of air quality and antibiotics. The results showed a higher weight gain of the broilers in the broiler house with a higher ventilation rate. SPI air purifier could benefit the weight gains of the broilers, but was not always significant. The uses of higher ventilation rate, SPI air purifier and antibiotics could reduce the mortality rate of broilers. The impact of air quality on reducing the serum cholesterol level of broilers was not found in this research. The inference of this research was that ventilation could be an effective way to increase the broiler productivity, while an optimum setting of ventilation rate is essential to ensure the broilers and keepers are safe from any harmful effects. In the case that the ambient environment had been severely polluted, air purifiers would be indispensable to complement ventilation to reduce certain target pollutants.
引用
收藏
页码:449 / 455
页数:7
相关论文
共 50 条
  • [21] Ventilation and Indoor Air Quality
    Kumar, Ashok
    Moreno-Rangel, Alejandro
    Khan, M. Amirul, I
    Piasecki, Michal
    ATMOSPHERE, 2022, 13 (10)
  • [22] A field study of indoor air quality and occupant perception in experimental laboratories and workshops
    Kwong, Qi Jie
    Abdullah, Jamalunlaili
    Tan, Sheng Chuan
    Thio, Tzer Hwai Gilbert
    Yeaw, Win Shyang
    MANAGEMENT OF ENVIRONMENTAL QUALITY, 2019, 30 (02) : 467 - 482
  • [23] Field measurement of the impact of natural ventilation and portable air cleaners on indoor air quality in three occupant states
    Yin H.
    Li Z.
    Zhai X.
    Ning Y.
    Gao L.
    Cui H.
    Ma Z.
    Li A.
    Energy and Built Environment, 2023, 4 (05): : 601 - 613
  • [24] Information system for indoor air quality field studies
    Bus, N
    Derbez, M
    Golliot, F
    Kirschner, S
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 613 - 617
  • [25] Indoor and outdoor air quality: A university cafeteria as a case study
    Alves, Celia A.
    Vicente, Estela D.
    Evtyugina, Margarita
    Vicente, Ana M.
    Nunes, Teresa
    Lucarelli, Franco
    Calzolai, Giulia
    Nava, Silvia
    Calvo, Ana, I
    del Blanco Alegre, Carlos
    Oduber, Fernanda
    Castro, Amaya
    Fraile, Roberto
    ATMOSPHERIC POLLUTION RESEARCH, 2020, 11 (03) : 531 - 544
  • [26] Indoor Air Quality in Community Health Centers: a preliminary study
    Santos, Luis
    Rebelo, Andreia
    Santos, Joana
    da Silva, Manuela Vieira
    OCCUPATIONAL SAFETY AND HYGIENE - SHO2013, 2013, : 447 - 449
  • [27] Impact of indoor air temperature and humidity in an office on perceived air quality, SBS symptoms and performance
    Fang, L
    Wyon, DP
    Clausen, G
    Fanger, PO
    INDOOR AIR, 2004, 14 : 74 - 81
  • [28] Reflections on the Evidentiary Basis of Indoor Air Quality Standards
    Berger, Christiane
    Mahdavi, Ardeshir
    Azar, Elie
    Bandurski, Karol
    Bourikas, Leonidas
    Harputlugil, Timucin
    Hellwig, Runa T.
    Rupp, Ricardo Forgiarini
    Schweiker, Marcel
    ENERGIES, 2022, 15 (20)
  • [29] Impact of kerosene space heaters on indoor air quality
    Hanoune, B.
    Carteret, M.
    CHEMOSPHERE, 2015, 134 : 581 - 587
  • [30] Low-Carbon Housings and Indoor Air Quality
    Yu, Chuck W. F.
    Kim, Jeong Tai
    INDOOR AND BUILT ENVIRONMENT, 2012, 21 (01) : 5 - 15