Laser processed calcium phosphate reinforced CoCrMo for load-bearing applications: Processing and wear induced damage evaluation

被引:61
作者
Sahasrabudhe, Himanshu [1 ]
Bose, Susmita [1 ]
Bandyopadhyay, Amit [1 ]
机构
[1] Washington State Univ, Sch Mech & Mat Engn, WM Keck Biomed Mat Res Lab, Pullman, WA 99164 USA
基金
美国国家科学基金会;
关键词
CoCrMo alloys; Load-bearing implants; Wear damage; In vivo; Laser processing; CO-CR-MO; TOTAL HIP PROSTHESES; DIAMOND-LIKE CARBON; COBALT-BASE ALLOY; METAL-ION RELEASE; CAST COCRMO; TRIBOLOGICAL CHARACTERIZATION; TRIBOCORROSION BEHAVIOR; CORROSION BEHAVIOR; HEAT-TREATMENT;
D O I
10.1016/j.actbio.2017.11.022
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To mitigate shortcomings in current biomedical CoCrMo alloy, composites of CoCrMo with calcium phosphate (CaP) were envisioned. CoCrMo alloy was reinforced with CaP to enhance the wear resistance of the alloy. A powder based direct energy additive manufacturing technique of Laser Engineered Net Shaping (LENS (TM)) was used for processing of CoCrMo alloy with 1% and 3% (by weight) of CaP in the form of hydroxyapaptite. Addition of CaP was found to stabilize the epsilon (hcp) phase along with the more common gamma (fcc) phase of the CoCrMo alloy, and the microstructure showed discontinuous chromium carbide phase. The resultant composite showed hardness similar to the base material, however, there was significant increase in the wear resistance of the alloy due to the addition of CaP. During wear testing, a tribolayer or a tribofilm was found to develop on the surface. This led to the reduction in the leaching of Co and Cr ions during wear testing. The tribofilm was found to be dependent on the wear distance, and made the CoCrMo-CaP composites an in situ self-protecting system. The overall coefficient of friction of the CoCrMo-CaP composite was found to increase but was more stable with the wear distance as compared to the CoCrMo alloy with no CaP addition. Statement of Significance Co-based alloys, an ideal choice for biomedical load-bearing implants, show low wear rates along with low coefficient of friction (COF) and good resistance to corrosive media. However, significant material loss can occur in vivo due to wear and/or corrosion of CoCrMo over long periods of time. Release of metal ions in the human body over time leads to medical complications such as metallosis, which can often require a revision surgery that can adversely affect the quality of life for the patient. We hypothesize that metal ion release from CoCrMo alloys can be reduced during articulation using an in situ formed inorganic tribofilm, and our results validate our hypothesis in calcium phosphate reinforced CoCrMo composites. (C) 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:118 / 128
页数:11
相关论文
共 57 条
[1]   Biotribological response of Co-Cr alloy with added boron under ball-on-disc tests [J].
Alvarez-Vera, M. ;
Juarez-Hernandez, A. ;
Gonzalez-Rivera, C. E. ;
Mercado-Solis, R. D. ;
Hernandez-Rodriguez, M. A. L. .
WEAR, 2013, 301 (1-2) :243-249
[2]   A study of the wear performance in a hip simulator of a metal-metal Co-Cr alloy with different boron additions [J].
Alvarez-Vera, M. ;
Ortega-Saenz, J. A. ;
Hernandez-Rodriguez, M. A. L. .
WEAR, 2013, 301 (1-2) :175-181
[3]  
[Anonymous], 2010, G13305 ASTM INT
[4]   Characterization of Co-Cr-Mo alloys after a thermal treatment for high wear resistance [J].
Balagna, C. ;
Spriano, S. ;
Faga, M. G. .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2012, 32 (07) :1868-1877
[5]   Laser processed TiN reinforced Ti6Al4V composite coatings [J].
Balla, Vamsi Krishna ;
Bhat, Abhimanyu ;
Bose, Susmita ;
Bandyopadhyay, Amit .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 6 :9-20
[6]   Calcium phosphate-titanium composites for articulating surfaces of load-bearing implants [J].
Bandyopadhyay, Amit ;
Dittrick, Stanley ;
Gualtieri, Thomas ;
Wu, Jeffrey ;
Bose, Susmita .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 57 :280-288
[7]  
BOSE S., 2017, PROGR MAT SCI
[8]   Subsurface microstructure of metal-on-metal hip joints and its relationship to wear particle generation [J].
Büscher, R ;
Täger, G ;
Dudzinski, W ;
Gleising, B ;
Wimmer, MA ;
Fischer, A .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 72B (01) :206-214
[9]   A tribological study of cobalt chromium molybdenum alloys used in metal-on-metal resurfacing hip arthroplasty [J].
Cawley, J ;
Metcalf, JEP ;
Jones, AH ;
Band, TJ ;
Skupien, DS .
WEAR, 2003, 255 :999-1006
[10]   Sliding wear behaviour of laser clad coatings based upon a nickel-based self-fluxing alloy co-deposited with conventional and nanostructured tungsten carbide-cobalt hardmetals [J].
Chen, H ;
Xu, C ;
Qu, J ;
Hutchings, IM ;
Shipway, PH ;
Liu, J .
WEAR, 2005, 259 :801-806