In Vitro Analysis of the Tribological Behaviour of Different Material Combinations for Telescopic Crowns

被引:1
作者
Linek, Wigbert [1 ]
Richter, Gert [1 ]
Raedel, Michael [1 ]
Walter, Michael [1 ]
Reitemeier, Bernd [1 ]
机构
[1] Tech Univ Dresden, Fac Med, Dept Prosthet Dent, Fetscherstr 74, D-01307 Dresden, Germany
来源
METALS | 2016年 / 6卷 / 07期
关键词
dental crowns; telescopic crowns; tribological behaviour; long-term test; pull-off force; surface roughness; REMOVABLE PARTIAL DENTURES; LONG-TERM USE; RETAINED DENTURES; RETENTION; FORCE; PROSTHESES; TITANIUM; DESIGN; SYSTEM; ALLOYS;
D O I
10.3390/met6070149
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Telescopic crowns are used to connect removable dental prostheses with the remaining dentition. Several material combinations are used for manufacturing primary and secondary crowns. The present experimental study analysed the influence of different material combinations on the long-term development of surface roughness and pull-off forces. Six different material combinations were tested. Secondary crowns were manufactured either by casting or electroforming. Each material combination was tested with n = 10 specimens. A material testing device with integrated power sensors was used for 10,000 cycles per test. Signs of wear were identified by surface roughness measurements, and visualized by a scanning electron microscope (SEM) and X-ray spectroscopy (EDX) technologies. Statistical significances were tested by using the U-Test with Bonferroni correction. The choice of materials and the manufacturing process were found to influence the long-term development of pull-off forces as well as wear-associated surface roughness. Combinations of different groups of materials for primary and secondary crowns showed favourable results. Worse results were found for the combination pure titanium and pure titanium and the combination high gold alloy and electroformed gold. Wear-associated surface roughness was higher for combinations of similar or identical groups of materials. For manufacturing telescopic crowns, combinations of different groups of materials are preferred. For secondary crown manufacturing, electroforming is superior to casting.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] An in vitro comparison of retention of provisional crowns cemented with provisional cement enriched with three different additives
    Joshi, Ravi
    Shah, Dipti
    Vaishnav, Kalpesh
    Patel, Aneri
    Patel, Manish
    Agnihotri, Radhika
    ADVANCES IN HUMAN BIOLOGY, 2023, 13 (04) : 327 - 332
  • [32] Experimental investigation on the mechanical and tribological coupled behaviour of bimetal composite under different states
    Li, Zhou
    Zhao, Jingwei
    Wu, Hui
    Jia, Fanghui
    Yao, Ye
    Zhang, Qingfeng
    Jiao, Sihai
    Jiang, Zhengyi
    SURFACE TOPOGRAPHY-METROLOGY AND PROPERTIES, 2019, 7 (02):
  • [33] Comparative analysis of stress distribution around CFR-PEEK implants and titanium implants with different prosthetic crowns: A finite element analysis
    Tamrakar, Swapnil Kumar
    Mishra, Sunil Kumar
    Chowdhary, Ramesh
    Rao, Srinivas
    DENTAL AND MEDICAL PROBLEMS, 2021, 58 (03) : 359 - 367
  • [34] Experimental and numerical investigations in CNC turning for different combinations of tool inserts and workpiece material
    Verma, Mayur
    Pradhan, Sharad K.
    MATERIALS TODAY-PROCEEDINGS, 2020, 27 : 2736 - 2743
  • [35] Fracture strength of yttria-stabilized tetragonal zirconia polycrystals crowns with different design: an in vitro study
    Larsson, Christel
    El Madhoun, Sammah
    Wennerberg, Ann
    von Steyern, Per Vult
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (07) : 820 - 826
  • [36] Effect of Implant Abutment Acid Etching on the Retention of Crowns Luted with Different Cements: An In Vitro Comparative Evaluation
    Ajay, R.
    Rakshagan, V
    Kamatchi, M.
    SelvaBalaji, A.
    Sivakumars, Jambai Sampath Kumar
    Kumar, M. Senthil
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2019, 11 : S360 - S364
  • [37] Functionally graded bi-material interface for Porcelain Veneered Zirconia dental crowns: A study using viscoelastic finite element analysis
    Shrestha, Rupesh
    Reddy, Niyati
    Fredeen, Steven
    Zhang, Yu
    Kim, Jeongho
    DENTAL MATERIALS, 2024, 40 (08) : 1267 - 1281
  • [38] Mechanism of material removal during tribological behaviour of aluminium matrix (Al-Zn-Mg-Cu) composites
    Rao, R. N.
    Das, S.
    Mondal, D. P.
    Dixit, G.
    TRIBOLOGY INTERNATIONAL, 2012, 53 : 179 - 184
  • [39] Assessment of the survival and success rates of lithium disilicate crowns after different surface finishing procedures: An in vitro study
    da Rocha, Larissa Simiao
    Della Bona, Alvaro
    Pretto, Mauren Depra
    Corazza, Pedro Henrique
    Borba, Marcia
    Benetti, Paula
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (06) : 897 - 905
  • [40] Comparative evaluation of retention of lithium disilicate crowns with four different cementation systems- An in-vitro Study
    Talukdar, Dhaniram
    Dua, Bharti
    Datta, Pankaj
    Bhardwaj, Anupam
    JOURNAL OF PHARMACEUTICAL NEGATIVE RESULTS, 2022, 13 : 1090 - 1096