In Vitro Analysis of the Tribological Behaviour of Different Material Combinations for Telescopic Crowns

被引:1
|
作者
Linek, Wigbert [1 ]
Richter, Gert [1 ]
Raedel, Michael [1 ]
Walter, Michael [1 ]
Reitemeier, Bernd [1 ]
机构
[1] Tech Univ Dresden, Fac Med, Dept Prosthet Dent, Fetscherstr 74, D-01307 Dresden, Germany
来源
METALS | 2016年 / 6卷 / 07期
关键词
dental crowns; telescopic crowns; tribological behaviour; long-term test; pull-off force; surface roughness; REMOVABLE PARTIAL DENTURES; LONG-TERM USE; RETAINED DENTURES; RETENTION; FORCE; PROSTHESES; TITANIUM; DESIGN; SYSTEM; ALLOYS;
D O I
10.3390/met6070149
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Telescopic crowns are used to connect removable dental prostheses with the remaining dentition. Several material combinations are used for manufacturing primary and secondary crowns. The present experimental study analysed the influence of different material combinations on the long-term development of surface roughness and pull-off forces. Six different material combinations were tested. Secondary crowns were manufactured either by casting or electroforming. Each material combination was tested with n = 10 specimens. A material testing device with integrated power sensors was used for 10,000 cycles per test. Signs of wear were identified by surface roughness measurements, and visualized by a scanning electron microscope (SEM) and X-ray spectroscopy (EDX) technologies. Statistical significances were tested by using the U-Test with Bonferroni correction. The choice of materials and the manufacturing process were found to influence the long-term development of pull-off forces as well as wear-associated surface roughness. Combinations of different groups of materials for primary and secondary crowns showed favourable results. Worse results were found for the combination pure titanium and pure titanium and the combination high gold alloy and electroformed gold. Wear-associated surface roughness was higher for combinations of similar or identical groups of materials. For manufacturing telescopic crowns, combinations of different groups of materials are preferred. For secondary crown manufacturing, electroforming is superior to casting.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Retention forces between primary and secondary CAD/CAM manufactured telescopic crowns: an in vitro comparison of common material combinations
    Martin Schimmel
    Moritz Walther
    Nadin Al-Haj Husain
    Kensuke Igarashi
    Julia Wittneben
    Samir Abou-Ayash
    Clinical Oral Investigations, 2021, 25 : 6297 - 6307
  • [2] Retention forces between primary and secondary CAD/CAM manufactured telescopic crowns: an in vitro comparison of common material combinations
    Schimmel, Martin
    Walther, Moritz
    Al-Haj Husain, Nadin
    Igarashi, Kensuke
    Wittneben, Julia
    Abou-Ayash, Samir
    CLINICAL ORAL INVESTIGATIONS, 2021, 25 (11) : 6297 - 6307
  • [3] Retention force assessment in conical crowns in different material combinations
    Pietruski, Jan K.
    Sajewicz, Eugeniusz
    Sudnik, Jacek
    Pietruska, Malgorzata D.
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2013, 15 (01) : 35 - 42
  • [4] Comparative Stress Analysis of Polyetherketoneketone (PEKK) Telescopic Crowns Supported by Different Primary Crown Materials
    Tribst, Joao Paulo Mendes
    Dal Piva, Amanda Maria de Oliveira
    Syed, Azeem Ul Yaqin
    Alrabiah, Mohammed
    Al-Aali, Khulud A.
    Vohra, Fahim
    Abduljabbar, Tariq
    APPLIED SCIENCES-BASEL, 2022, 12 (07):
  • [5] EVALUATION OF THE FORCE RETENTION WITHIN THE TELESCOPIC CROWNS WITH DIFFERENT TAPER ANGLES BY FINITE ELEMENT ANALYSIS
    Fischer, Caroline Adela Ingrid
    Baciu, Florin
    Vranceanu, Diana Maria
    Zamfir, Raluca Ioana
    Coman, Costin
    Comaneanu, Raluca Monica
    Ghergic, Doina Lucia
    UPB Scientific Bulletin, Series B: Chemistry and Materials Science, 2022, 84 (03): : 169 - 178
  • [6] EVALUATION OF THE FORCE RETENTION WITHIN THE TELESCOPIC CROWNS WITH DIFFERENT TAPER ANGLES BY FINITE ELEMENT ANALYSIS
    Fischer, Caroline Adela Ingrid
    Baciu, Florin
    Vranceanu, Diana Maria
    Zamfir, Raluca Ioana
    Coman, Costin
    Comaneanu, Raluca Monica
    Ghergic, Doina Lucia
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES B-CHEMISTRY AND MATERIALS SCIENCE, 2022, 84 (03): : 169 - 178
  • [7] In vitro wear of different material combinations of Intracoronal precision attachments
    Holst, Stefan
    Blatz, Markus B.
    Eitner, Stephan
    Wichmann, Manfred
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2006, 19 (04) : 330 - 332
  • [8] THE TRIBOLOGICAL BEHAVIOUR OF CERAMIC MATERIAL
    Armencia, Adina Oana
    Laurian, Tiberiu
    Ursache, Maria
    ROMANIAN JOURNAL OF ORAL REHABILITATION, 2009, 1 (03): : 24 - 29
  • [9] Retention force of differently fabricated telescopic PEEK crowns with different tapers
    Stock, Veronika
    Wagner, Christina
    Merk, Susanne
    Roos, Malgorzata
    Schmidlin, Patrick R.
    Eichberger, Marlis
    Stawarczyk, Bogna
    DENTAL MATERIALS JOURNAL, 2016, 35 (04) : 594 - 600
  • [10] Survival of different acrylate based veneer materials in telescopic crowns.
    Lammert, U
    Riebeling, A
    Ferger, P
    Wòstmann, B
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 263 - 263