In vitro biomechanical comparison of three methods for internal fixation of femoral neck fractures in dogs

被引:5
作者
Fisher, S. C. [1 ]
McLaughlin, R. M. [1 ]
Elder, S. H. [2 ]
机构
[1] Mississippi State Univ, Coll Vet Med, Dept Clin Sci, Mississippi State, MS 39762 USA
[2] Mississippi State Univ, Dept Agr & Biol Engn, Mississippi State, MS 39762 USA
关键词
Femoral neck fractures; Orthofix pin; compression; lag screw; divergent pins; ORTHOFIX PINS; REPAIR;
D O I
10.3415/VCOT-11-03-0045
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The in vitro biomechanical properties of three methods for internal fixation of femoral neck fractures were evaluated. Fifty cadaveric femura from Beagle dogs were used. Ten intact femora served as controls. In 40 femura, an osteotomy of the femoral neck was performed to simulate a transverse fracture. With the remaining 30 femura, three repair methods (two medium Orthofix pins, a 2.7 mm cortical bone screw placed in lag fashion and an anti-rotational Kirschner wire, or three divergent 1.1 mm Kirschner wires) were used to stabilize the osteotomies, and 10 osteotomies were stabilised per repair method. These 30 femura where then subject to monotonic loading to failure. Construct stiffness and load to failure were measured. In the remaining 10 femura, pressure sensitive film was placed at the osteotomy site prior to stabilization with either two Orthofix pins (n = 5) or a screw placed in lag fashion (n = 5) to determine the compressive pressure (MPa), compressive force (KN) and area of compression (cm(2)). There was no significant difference in the stiffness or load to failure for the three repair methods evaluated. There was no significant difference in the compressive pressure, compressive force or area of compression in osteotomies stabilized with Orthofix pins and 2.7 mm bone screws.
引用
收藏
页码:36 / 41
页数:6
相关论文
共 18 条
[1]   Orthopedic clinical techniques femur fracture repair [J].
Beale, B .
CLINICAL TECHNIQUES IN SMALL ANIMAL PRACTICE, 2004, 19 (03) :134-150
[2]  
Brinker WO, 1966, ANIM HOSP, V2, P160
[3]  
Daly W R, 1978, Vet Surg, V7, P29, DOI DOI 10.1111/J.1532-950X.1978.TB00576.X
[4]   Evaluation of compression generated by self compressing Orthofix bone pins and lag screws in simulated lateral humeral condylar fractures [J].
Daubs, B. M. ;
McLaughlin, R. M. ;
Silverman, E. ;
Rizon, J. .
VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2007, 20 (03) :175-179
[5]   Evaluation of surgical repair of humeral condylar fractures using self-compressing orthofix pins in 23 dogs [J].
Guille, AE ;
Lewis, DD ;
Anderson, TP ;
Beaver, DP ;
Carrera-Justiz, SC ;
Thompson, MS ;
Wheeler, JL .
VETERINARY SURGERY, 2004, 33 (04) :314-322
[6]  
Hulse D. A., 1974, Journal of the American Animal Hospital Association, V10, P29
[7]   INTERNAL-FIXATION OF FEMORAL-HEAD AND NECK FRACTURES IN THE CAT [J].
JEFFERY, ND .
JOURNAL OF SMALL ANIMAL PRACTICE, 1989, 30 (12) :674-677
[8]  
Johnson AL, 2007, SMALL ANIMAL SURG, P1015
[9]  
LAMBRECHTS NE, 1993, VET COMP ORTHOPAED, V6, P13
[10]  
Lanz OI, 1999, VET COMP ORTHOPAED, V12, P88