Amikacin prevents platelet aggregation in feline venous blood samples

被引:2
作者
Engelmann, Ana M. [1 ]
Veleda, Patricia A. [1 ]
Mello, Camila B. E. [1 ]
Dutra, Lara S. [1 ]
Mann, Thais R. [1 ]
Bueno, Andressa [1 ]
Krause, Alexandre [1 ]
Andrade, Cinthia M. [1 ]
机构
[1] Univ Fed Santa Maria, Dept Small Anim Clin, Vet Hosp, Roraima Ave 1000, BR-97105900 Santa Maria, RS, Brazil
关键词
aminoglycoside; domestic animals; pseudothrombocytopenia; venipuncture; EDTA; VOLUME; PROSTAGLANDIN-E1; HEMATOLOGY; COUNTS; CATS;
D O I
10.1111/vcp.13074
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Introduction Physiologically, feline platelets are more reactive and prone to aggregation, which interferes with platelet counts using automated counters and manual methods. The use of aminoglycoside amikacin in association with EDTA has proven to be efficient in preventing platelet aggregates in cases of pseudo thrombocytopenia (PTP) in people. Objectives This study evaluated the efficacy of amikacin in preventing platelet aggregation in EDTA-containing feline blood samples and investigated the possible effects on hematologic measurands. Materials and methods Blood samples (1.0 mL) collected from 100 healthy cats were stored in two EDTA tubes: 0.5 mL in a microtube containing 10 mu L of 250 mg/mL amikacin (EDTA-AMK group) and 0.5 mL in a microtube containing only K2 EDTA 10% (EDTA group). A CBC was executed with an automated impedance blood analyzer, and a microscopic examination of the blood smears was performed. Results Platelet clumps were observed in 56% of samples from the EDTA group and 5% of samples from the EDTA-AMK group. Platelet counts (PLT), plateletcrit (PCT), and WBC counts were significantly higher (P < .001) in the EDTA-AMK group compared withi the EDTA group. Conclusions Amikacin prevents platelet aggregation in feline venous blood samples and does not cause clinically relevant changes in other hematologic measurands. To our knowledge, this is the first report showing the use of amikacin in preventing platelet aggregation in feline blood samples. Based on this study, amikacin could be added to EDTA collection tubes for complete blood counts in cats.
引用
收藏
页码:51 / 56
页数:6
相关论文
共 24 条
[21]  
WEISER MG, 1984, AM J VET RES, V45, P518
[22]  
Weiss D.J., 2012, Small Animal Clinical Diagnosis by Laboratory Methods. p, P12
[23]   Effect of prewarming EDTA blood samples to 37°C on platelet count measured by Sysmex XT-2000iV in dogs, cats, and horses [J].
Williams, Tim L. ;
Archer, Joy .
VETERINARY CLINICAL PATHOLOGY, 2016, 45 (03) :444-449
[24]   Automated analysis of feline platelets in whole blood, including platelet count, mean platelet volume, and activation state [J].
Zelmanovic, D ;
Hetherington, EJ .
VETERINARY CLINICAL PATHOLOGY, 1998, 27 (01) :2-9