Selecting a Press-fit Stem for Total Hip Arthroplasty: The Rationale and Evolution of the Modern Femoral Prosthesis

被引:6
|
作者
Blankstein, Michael
Haimes, Mark A. [1 ]
Nelms, Nathaniel J.
机构
[1] Univ Vermont, Med Ctr, Orthoped & Rehabil Ctr, Burlington, VT 05405 USA
关键词
CEMENTLESS STEMS; FRACTURE RISK; PORE-SIZE; FIXATION; HYDROXYAPATITE; REPLACEMENTS; REGISTRY; SMOOTH; RATES; WEAR;
D O I
10.5435/JAAOS-D-22-00074
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Noncemented press-fit femoral stems predominate in total hip arthroplasty for all age groups with generally excellent long-term survivorship. The 2021 American Joint Replacement Registry reports that 96% of all elective primary total hip arthroplasties used noncemented femoral implant fixation.(1) Today, there are many styles of press-fit stems, each with supposed benefits, based on a range of design philosophies. Design aspects to consider when selecting a stem are numerous, including stem geometry, stem length, collared or collarless, material properties, and surface structure. Although most stem designs demonstrate excellent results, the differences in stem designs are intimately linked to additional factors such as ease of use/ implantation, percentage of surface osseointegration, overall bone removal versus bone stock preservation, subsequent femoral stress shielding, and consideration of complexity of later revision. A surgeon with a broad understanding and appreciation of femoral stem designs should be prepared to select between the multitude of options to best serve individual patients.
引用
收藏
页码:E1279 / E1290
页数:12
相关论文
共 50 条
  • [11] Total hip arthroplasty using a short-stem prosthesis: restoration of hip anatomy
    Amenabar, Tomas
    Marimuthu, Kanniraj
    Hawdon, Gabrielle
    Gildone, Alessandro
    McMahon, Stephen
    JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (01) : 90 - 94
  • [12] Influence of the taper on the fretting wear of the femoral stem-femoral head taper junction in total hip prosthesis
    Capitanu, Lucian
    Badita, Liliana-Laura
    Tiganesteanu, Constantin
    Florescu, Virgil
    INDUSTRIAL LUBRICATION AND TRIBOLOGY, 2022, 74 (04) : 385 - 391
  • [13] Alignment and Fixation in Revision Total Knee Arthroplasty With Press-Fit, Offset, Diaphyseal-Engaging Stem Extensions, and Eccentric Reaming Technique
    Vince, Kelly G.
    Hoskins, Wayne T.
    English, Michael
    JOURNAL OF ARTHROPLASTY, 2023, 38 (06) : S302 - S307
  • [14] Modular noncemented femoral stem system in revision total hip arthroplasty
    Schofer, M. D.
    Efe, T.
    Heyse, T. J.
    Timmesfeld, N.
    Velte, R.
    Hinrichs, F.
    Schmitt, J.
    ORTHOPADE, 2010, 39 (02): : 209 - +
  • [15] Mid-Term Outcomes of a Modern Zweymüller Monolithic Femoral Stem in Primary Total Hip Arthroplasty
    Ciriello, Vincenzo
    Saracco, Michela
    Leonardi, Enrico
    Piovani, Lucio
    Fetz-Palazola, Allison
    Mareno, Chase
    Logroscino, Giandomenico
    PROSTHESIS, 2024, 6 (01): : 53 - 62
  • [16] Reproducibility of Femoral Offset Following Short Stem and Straight Stem Total Hip Arthroplasty
    von Roth, Philipp
    Perka, Carsten
    Mayr, Hermann O.
    Preininger, Bernd
    Ziebula, Friedrich
    Matziolis, Georg
    Hube, Robert
    ORTHOPEDICS, 2014, 37 (07) : E678 - E684
  • [17] An investigation of the inelastic behaviour of trabecular bone during the press-fit implantation of a tibial component in total knee arthroplasty
    Kelly, N.
    Cawley, D. T.
    Shannon, F. J.
    McGarry, J. P.
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (11) : 1599 - 1606
  • [18] Influence of proximal femoral morphology on osteointegration of the AMIS uncemented femoral stem in modern hip arthroplasty
    Maton, Maxime
    Vandromme, Emile
    Charles, Tatiana
    Kapanci, Bilal
    Jayankura, Marc
    ARTHROPLASTY, 2024, 6 (01)
  • [19] Total hip arthroplasty for acute femoral neck fractures using a cementless tapered femoral stem
    Klein, Gregg R.
    Parvizi, Javad
    Vegari, David N.
    Rothman, Richard H.
    Purtill, James J.
    JOURNAL OF ARTHROPLASTY, 2006, 21 (08) : 1134 - 1140
  • [20] Comparison of cortical and cancellous bone remodeling of the pelvis after press-fit cup total hip arthroplasty dependent on patient and prosthesis-specific characteristics: a computed tomography-assisted osteodensitometry study in vivo
    Zingler, Katharina
    Haeberle, Lothar
    Kress, Alexander
    Holzwarth, Ulrich
    Forst, Raimund
    Mueller, Lutz A.
    Schmidt, Rainer
    BIOMEDIZINISCHE TECHNIK, 2011, 56 (05): : 267 - 275