Fluid-structure interaction of deformable aortic prostheses with a bileaflet mechanical valve

被引:27
作者
de Tullio, M. D. [1 ,2 ]
Afferrante, L. [1 ,2 ]
Demelio, G. [1 ,2 ]
Pascazio, G. [1 ,2 ]
Verzicco, R. [3 ]
机构
[1] Politecn Bari, DIMeG, I-70125 Bari, Italy
[2] Politecn Bari, CEMeC, I-70125 Bari, Italy
[3] Univ Roma Tor Vergata, DIM, I-00133 Rome, Italy
关键词
Bentall procedure; Valsalva graft; Immersed boundary method; HEART-VALVE; BENTALL PROCEDURE; FLOW; SIMULATION; REPLACEMENT; ELEMENT; STRAIN;
D O I
10.1016/j.jbiomech.2011.03.036
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Two different aortic prostheses can be used for performing the Bentall procedure: a standard straight graft and the Valsalva graft that better reproduces the aortic root anatomy. The aim of the present work is to study the effect of the graft geometry on the blood flow when a bileaflet mechanical heart valve is used, as well as to evaluate the stress concentration near the suture line where the coronary arteries are connected to graft. An accurate three-dimensional numerical method is proposed, based on the immersed boundary technique. The method accounts for the interactions between the flow and the motion of the rigid leaflets and of the deformable aortic root, under physiological pulsatile conditions. The results show that the graft geometry only slightly influences the leaflets dynamics, while using the Valsalva graft the stress level near the coronary-root anastomoses is about half that obtained using the standard straight graft. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1684 / 1690
页数:7
相关论文
共 26 条
[1]  
*ANSYS INC, 2008, MULT
[2]   Fluid-structure interaction and multi-body contact: Application to aortic valves [J].
Astorino, Matteo ;
Gerbeau, Jean-Frederic ;
Pantz, Olivier ;
Traore, Karim-Frederic .
COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2009, 198 (45-46) :3603-3612
[3]  
Baaijens FPT, 2001, INT J NUMER METH FL, V35, P743, DOI 10.1002/1097-0363(20010415)35:7<743::AID-FLD109>3.0.CO
[4]  
2-A
[5]   A TECHNIQUE FOR COMPLETE REPLACEMENT OF ASCENDING AORTA [J].
BENTALL, H ;
DEBONO, A .
THORAX, 1968, 23 (04) :338-&
[6]   An approach to the simulation of fluid-structure interaction in the aortic valve [J].
Carmody, CJ ;
Burriesci, G ;
Howard, IC ;
Patterson, EA .
JOURNAL OF BIOMECHANICS, 2006, 39 (01) :158-169
[7]   A three-dimensional computational analysis of fluid-structure interaction in the aortic valve [J].
De Hart, J ;
Peters, GWM ;
Schreurs, PJG ;
Baaijens, FPT .
JOURNAL OF BIOMECHANICS, 2003, 36 (01) :103-112
[8]   Coronary flow characteristics after a Bentall procedure with or without sinuses of Valsalva [J].
De Paulis, R ;
Tomai, F ;
Bertoldo, F ;
Ghini, AS ;
Scaffa, R ;
Nardi, P ;
Chiariello, L .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 26 (01) :66-72
[9]   On the effect of aortic root geometry on the coronary entry-flow after a bileaflet mechanical heart valve implant: a numerical study [J].
de Tullio, M. D. ;
Pedrizzetti, G. ;
Verzicco, R. .
ACTA MECHANICA, 2011, 216 (1-4) :147-163
[10]   Direct numerical simulation of the pulsatile flow through an aortic bileaflet mechanical heart valve [J].
De Tullio, M. D. ;
Cristallo, A. ;
Balaras, E. ;
Verzicco, R. .
JOURNAL OF FLUID MECHANICS, 2009, 622 :259-290