Experimental design optimization of the capillary electrophoresis separation of leucine enkephalin and its immune complex

被引:9
作者
Babar, Sheikh Md. Enayetul
Song, Eun Joo
Hasan, Md. Nabiul
Yoo, Young Sook
机构
[1] Korea Inst Sci & Technol, Life Sci Res Div, Bional & Biotransformat Res Ctr, Seoul 130650, South Korea
[2] Korea Inst Sci & Technol, Int R&D Acad, Seoul 130650, South Korea
[3] Univ Sci & Technol, Taejon, South Korea
关键词
capillary electrophoresis; Box-Behnken design; leucine enkephalin;
D O I
10.1002/jssc.200700145
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To optimize the capillary electrophoretic separation conditions for leucine enkephalin (LE) and the immune complex of the LE and anti-LE reaction, an analysis using a three-level, three-factorial Box-Behnken design was performed. Three separation parameters, buffer pH (X-1), buffer concentration (X-2), and applied voltage (X-3), were chosen to observe the effect on separation responses. The responses were theoretical plate number, migration time of the LE peak, and resolution between the peaks. The optimum conditions and process validation were determined using statistical regression analysis and surface plot diagrams. The capillary electrophoresis optimum separation conditions were established to be 75 mM phosphate buffer at pH 7.00 with an applied separation voltage of 15 kV. By using the analysis technique, the prediction of responses was satisfactory and process verification yielded values within the +/- 5% range of the predicted efficiency.
引用
收藏
页码:2311 / 2319
页数:9
相关论文
共 20 条
  • [1] Capillary electrophoretic competitive immunoassay with laser-induced fluorescence detection for methionine-enkephalin
    Babu, CVS
    Chung, BC
    Lho, DS
    Yoo, YS
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1111 (02) : 133 - 138
  • [2] Babu CVS, 2005, ELECTROPHORESIS, V26, P3765, DOI [10.1002/elps.20050007, 10.1002/elps.200500007]
  • [3] Experimental design to investigate factors affecting capillary zone electrophoresis
    Babu, CVS
    Chung, BC
    Yoo, YS
    [J]. ANALYTICAL LETTERS, 2004, 37 (12) : 2485 - 2499
  • [4] Capillary electrophoresis at the omics level: Towards systems biology
    Babu, S
    Song, EJ
    Babar, SME
    Wi, MH
    Yoo, YS
    [J]. ELECTROPHORESIS, 2006, 27 (01) : 97 - 110
  • [5] PEPTIDE-TRANSPORT SYSTEMS FOR OPIATES ACROSS THE BLOOD-BRAIN-BARRIER
    BANKS, WA
    KASTIN, AJ
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 259 (01): : E1 - E10
  • [6] Optimization of propranolol hydrochloride sustained-release pellets using Box-Behnken design and desirability function
    Bodea, A
    Leucuta, SE
    [J]. DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1998, 24 (02) : 145 - 155
  • [7] Box GEP., 1960, TECHNOMETRICS, V2, P455, DOI [10.2307/1266454, DOI 10.1080/00401706.1960.10489912, 10.1080/00401706.1960.10489912]
  • [8] Cocharn WG., 1992, EXPT DESIGNS
  • [9] Development and validation method for determination of Paroxetine and its metabolites by nonaqueous capillary electrophoresis in human urine.: Experimental design for evaluating the ruggedness of the method
    Flores, JR
    Nevado, JJB
    Salcedo, AMC
    Díaz, MRC
    [J]. ELECTROPHORESIS, 2004, 25 (03) : 454 - 462
  • [10] Response surface methodology in the development of a stacking-sensitive capillary electrophoresis method for the analysis of tricyclic antidepressants in human serum
    Galeano-Díaz, T
    Acedo-Valenzuela, MI
    Mora-Diéz, N
    Silva-Rodríguez, A
    [J]. ELECTROPHORESIS, 2005, 26 (18) : 3518 - 3527