Metrological traceability method for atomic absolute gravimeters

被引:12
|
作者
Zhu, Dong [1 ]
Zhou, Yin [1 ]
Wu, Bin [1 ]
Weng, Kanxing [1 ]
Wang, Kainan [1 ]
Cheng, Bing [1 ]
Lin, Qiang [1 ]
机构
[1] Zhejiang Univ Technol, Coll Sci, Zhejiang Prov Key Lab Quantum Precis Measurement, Hangzhou 310023, Peoples R China
基金
中国国家自然科学基金;
关键词
FIELD;
D O I
10.1364/AO.430370
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Cold atomic gravimeters are attracting more and more attention and activity in the area of gravity measurement and comparison, and the corresponding methods for measurement and traceability need to be explored. Based on two self-developed cold atomic gravimeters, research on the comparison and traceability methods of absolute gravity measurement was carried out. The entire gravity measurement traceability process is divided into two stages: the preliminary traceability in the laboratory and the formal traceability in the absolute gravity reference station. Through comparison of two atomic gravimeters (ZAG-E and ZAG-B) in the laboratory, the degree of equivalence D-D and the normalized deviation E-n of ZAG-E are obtained, which are -2.7 +/- 7.6 mu Gal (k = 2) and -0.3599, respectively. Relative to the absolute gravity reference at the National Institute of Metrology (NIM) in China, D-D and E-n of ZAG-E are 0.5 +/- 12.0 mu Gal (k = 2) and 0.0417, respectively. |E-n| <= 1 in the two traceability stages, so the results of two traceability stages are acceptable, which indicates the consistency of the comparisons is good. Finally, the absolute gravity measurement value of ZAG-E is traced to the SI units, ensuring its accuracy. A gravity traceability method for atomic gravimeters is given and is very beneficial for the applications of atomic gravimeters in metrology and other fields. (C) 2021 Optical Society of America
引用
收藏
页码:7910 / 7920
页数:11
相关论文
共 50 条
  • [1] The results of international metrological comparisons of absolute laser ballistic gravimeters
    Arnautov, G.P.
    Avtometriya, 2005, 41 (01): : 126 - 136
  • [2] A VIBRATION COMPENSATION METHOD FOR ABSOLUTE GRAVIMETERS
    Wang, Guan
    Hu, Hua
    Wu, Kang
    Wang, Lijun
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2016, VOL. 4B, 2017,
  • [3] Stability comparison of two absolute gravimeters:optical versus atomic interferometers
    Gillot, P.
    Francis, O.
    Landragin, A.
    Dos Santos, F. Pereira
    Merlet, S.
    METROLOGIA, 2014, 51 (05) : L15 - L17
  • [4] Absolute ballistic gravimeters
    Vitushkin L.F.
    Gyroscopy and Navigation, 2015, 6 (4) : 254 - 259
  • [5] Metrological timelines in traceability
    Ehrlich, CD
    Rasberry, SD
    SUCCESS IN THE 21ST CENTURY DEPENDS ON MODERN METROLOGY, VOLS 1-2, 1997, : 889 - 919
  • [6] Metrological timelines in traceability
    Ehrlich, CD
    Rasberry, SD
    METROLOGIA, 1997, 34 (06) : 503 - 514
  • [7] Metrological timelines in traceability
    Ehrlich, CD
    Rasberry, SD
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1998, 103 (01) : 93 - 105
  • [8] A vibration correction method for free-fall absolute gravimeters
    Qian, J.
    Wang, G.
    Wu, K.
    Wang, L. J.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2018, 29 (02)
  • [9] Comparison between two mobile absolute gravimeters: optical versus atomic interferometers
    Merlet, S.
    Bodart, Q.
    Malossi, N.
    Landragin, A.
    Dos Santos, F. Pereira
    Gitlein, O.
    Timmen, L.
    METROLOGIA, 2010, 47 (04) : L9 - L11
  • [10] The diffraction correction for absolute gravimeters
    van Westrum, D
    Niebauer, TM
    METROLOGIA, 2003, 40 (05) : 258 - 263