Left Ventricular Reverse Remodeling in Percutaneous and Surgical Aortic Bioprostheses: An Echocardiographic Study

被引:26
作者
Giannini, Cristina [1 ]
Petronio, Anna Sonia [1 ]
Nardi, Carmela [1 ]
De Carlo, Marco [1 ]
Guarracino, Fabio [1 ]
Delle Donne, Maria Grazia [1 ]
Talini, Enrica [1 ]
Minzioni, Gaetano [1 ]
Bortolotti, Uberto [1 ]
Cucco, Cuono [1 ]
Marzilli, Mario [1 ]
Di Bello, Vitantonio [1 ]
机构
[1] Univ Pisa, Cardiac Imaging Lab, Cardiac Thorac & Vasc Dept, Pisa, Italy
关键词
Aortic stenosis; Surgical aortic valve replacement; Transcatheter aortic valve implantation; Echocardiography; PROSTHESIS-PATIENT MISMATCH; EXPANDING VALVE PROSTHESIS; HIGH-RISK PATIENTS; TRANSLUMINAL IMPLANTATION; EUROPEAN-SOCIETY; CLINICAL IMPACT; HEART-VALVES; REPLACEMENT; STENOSIS; FEASIBILITY;
D O I
10.1016/j.echo.2010.08.027
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Surgical aortic valve replacement (SAVR) is the definitive proven therapy for patients with severe aortic stenosis who have symptoms or decreased left ventricular (LV) function. The development of transcatheter aortic valve implantation (TAVI) offers a viable and "less invasive" option for the treatment of patients with critical aortic stenosis at high risk with conventional approaches. The main objective of this study was the comparison of LV hemodynamic and structural modifications (reverse remodeling) between percutaneous and surgical approaches in the treatment of severe aortic stenosis. Methods: Fifty-eight patients who underwent TAVI with the CoreValve bioprosthetic valve were compared with 58 patients with similar characteristics who underwent SAVR. Doppler echocardiographic data were obtained before the intervention, at discharge, and after 6-month to 12-month follow-up. Results: Mean transprosthetic gradient at discharge was lower (P < .003) in the TAVI group (10 +/- 5 mm Hg) compared with the SAVR group (14 6 5 mm Hg) and was confirmed at follow-up (10 +/- 4 vs 13 +/- 4 mm Hg, respectively, P < .001). Paravalvular leaks were more frequent in the TAVI group (trivial to mild, 69%; moderate, 14%) than in the SAVR group (trivial to mild, 30%; moderate, 0%) (P < .0001). The incidence of severe prosthesis-patient mismatch (PPM) was significantly lower (P < .004) in the TAVI group (12%) compared with the SAVR group (36%). At follow-up, LV mass and LV mass indexed to height and to body surface area improved in both groups, with no significant difference. In patients with severe PPM, only the TAVI subgroup showed significant reductions in LV mass. LV ejection fraction improved at follow-up significantly only in TAVI patients compared with baseline values (from 50.2 +/- 9.6% to 54.8 +/- 7.3%, P < .0001). Conclusions: Hemodynamic performance after TAVI was shown to be superior to that after SAVR in terms of transprosthetic gradient, LV ejection fraction, and the prevention of severe PPM, but with a higher incidence of aortic regurgitation. Furthermore, LV reverse remodeling was observed in all patients in the absence of PPM, while the same remodeling occurred only in the TAVI subgroup when severe PPM was present. (J Am Soc Echocardiogr 2011;24:28-36.)
引用
收藏
页码:28 / 36
页数:9
相关论文
共 43 条
[1]  
AELZER A, 1987, NEW ENGL J MED, V317, P91
[2]   TRANSLUMINAL IMPLANTATION OF ARTIFICIAL-HEART VALVES - DESCRIPTION OF A NEW EXPANDABLE AORTIC-VALVE AND INITIAL RESULTS WITH IMPLANTATION BY CATHETER TECHNIQUE IN CLOSED CHEST PIGS [J].
ANDERSEN, HR ;
KNUDSEN, LL ;
HASENKAM, JM .
EUROPEAN HEART JOURNAL, 1992, 13 (05) :704-708
[3]   Percutaneous Aortic Valve Implants Under Sedation: Our Initial Experience [J].
Behan, Miles ;
Haworth, Peter ;
Hutchinson, Nevil ;
Trivedi, Uday ;
Laborde, Jean-Claude ;
Hildick-Smith, David .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (07) :1012-1015
[4]   Validation of the 2000 Bernstein-Parsonnet score versus the EuroSCORE as a prognostic tool in cardiac surgery [J].
Berman, M ;
Stamler, A ;
Sahar, G ;
Georghiou, GP ;
Sharoni, E ;
Brauner, R ;
Medalion, B ;
Vidne, BA ;
Kogan, A .
ANNALS OF THORACIC SURGERY, 2006, 81 (02) :537-541
[5]   Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement [J].
Blais, C ;
Dumesnil, JG ;
Baillot, R ;
Simard, S ;
Doyle, D ;
Pibarot, P .
CIRCULATION, 2003, 108 (08) :983-988
[6]   Impact of patient-prosthesis mismatch on exercise capacity in patients after bioprosthetic aortic valve replacement [J].
Bleiziffer, S. ;
Eichinger, W. B. ;
Hettich, I. ;
Ruzicka, D. ;
Wottke, M. ;
Bauernschmitt, R. ;
Lange, R. .
HEART, 2008, 94 (05) :637-641
[7]  
Bonow RO., 2008, Circulation, V118, pe523, DOI [DOI 10.1161/CIRCULATIONAHA.108.190748, 10.1161/CIRCULATIONAHA.108.190748, 10.1161/CIRCULATIONAHA.108.190748.]
[8]   Aortic stenosis [J].
Carabello, Blase A. ;
Paulus, Walter J. .
LANCET, 2009, 373 (9667) :956-966
[9]   Comparison of the Hemodynamic Performance of Percutaneous and Surgical Bioprostheses for the Treatment of Severe Aortic Stenosis [J].
Clavel, Marie-Annick ;
Webb, John G. ;
Pibarot, Philippe ;
Altwegg, Lukas ;
Dumont, Eric ;
Thompson, Chris ;
De Larochelliere, Robert ;
Doyle, Daniel ;
Masson, Jean-Bernard ;
Bergeron, Sebastien ;
Bertrand, Olivier F. ;
Rodes-Cabau, Josep .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (20) :1883-1891
[10]   Anesthetic Management of Percutaneous Aortic Valve Implantation: Focus on Challenges Encountered and Proposed Solutions [J].
Covello, Remo Daniel ;
Maj, Giulia ;
Landoni, Giovanni ;
Maisano, Francesco ;
Michev, Iassen ;
Guarracino, Fabio ;
Alfieri, Ottavio ;
Colombo, Antonio ;
Zangrillo, Alberto .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2009, 23 (03) :280-285