Static and dynamic validation of inertial measurement units

被引:30
作者
Taylor, Leah [1 ]
Miller, Emily [1 ]
Kaufman, Kenton R. [1 ]
机构
[1] Mayo Clin, Mot Anal Lab, Dept Orthoped Surg, Rochester, MN 55905 USA
关键词
Validation; Inertial measurement units; Orientation; Angular velocity; YOUNG;
D O I
10.1016/j.gaitpost.2017.05.026
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Optical motion capture systems are used to assess human motion. While these systems provide a reliable analysis, they limit collection to a laboratory based setting. Devices such as Inertial Measurement Units (IMUs) have been developed as alternative tools. Commercially available IMUs are utilized for a variety of applications; however limited work has been done to determine the reliability of these devices. The objective of this study was to assess the accuracy and precision of a commercially available IMU, containing tri-axial accelerometers, gyroscopes, and magnetometers, under controlled static and dynamic conditions. The sensor output was validated against the gold standard measures of custom made mechanical testing apparatuses. The IMUs provide an accurate (within 0.6 degrees) and precise (within 0.1 degrees) measurement of static sensor orientation and an accurate (within 4.4 degrees per second) and precise (within 0.2 degrees per second) representation of angular velocity. The sensors are more accurate at lower velocities, but the percent error remains relatively constant across all angular velocities. Inclusion of IMUs as an appropriate measurement tool should be based on the application, specific demands and necessary reliability.
引用
收藏
页码:80 / 84
页数:5
相关论文
共 12 条
[1]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[2]   Methods for validating the performance of wearable motion-sensing devices under controlled conditions [J].
Bliley, Kara E. ;
Kaufman, Kenton R. ;
Gilbert, Barry K. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2009, 20 (04)
[3]  
Division NMPaA, 1977, EUL ANGL QUAT TRANSF
[4]   Maximum Velocities in Flexion and Extension Actions for Sport [J].
Jessop, David M. ;
Pain, Matthew T. G. .
JOURNAL OF HUMAN KINETICS, 2016, 50 (01) :37-44
[5]   Inertial Measures of Motion for Clinical Biomechanics: Comparative Assessment of Accuracy under Controlled Conditions - Effect of Velocity [J].
Lebel, Karina ;
Boissy, Patrick ;
Hamel, Mathieu ;
Duval, Christian .
PLOS ONE, 2013, 8 (11)
[6]   3D gait assessment in young and elderly subjects using foot-worn inertial sensors [J].
Mariani, Benoit ;
Hoskovec, Constanze ;
Rochat, Stephane ;
Buela, Christophe ;
Penders, Julien ;
Aminian, Kamiar .
JOURNAL OF BIOMECHANICS, 2010, 43 (15) :2999-3006
[7]   Accelerometer and rate gyroscope measurement of kinematics: an inexpensive alternative to optical motion analysis systems [J].
Mayagoitia, RE ;
Nene, AV ;
Veltink, PH .
JOURNAL OF BIOMECHANICS, 2002, 35 (04) :537-542
[8]   Mechanical testing for three-dimensional motion analysis reliability [J].
Miller, Emily ;
Kaufman, Kenton ;
Kingsbury, Trevor ;
Wolf, Erik ;
Wilken, Jason ;
Wyatt, Marilynn .
GAIT & POSTURE, 2016, 50 :116-119
[9]   The demands of stair descent relative to maximum capacities in elderly and young adults [J].
Reeves, N. D. ;
Spanjaard, M. ;
Mohagheghi, A. A. ;
Baltzopoulos, V. ;
Maganaris, C. N. .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2008, 18 (02) :218-227
[10]   Sit to stand from progressively lower seat heights - Alterations in angular velocity [J].
Schenkman, M ;
Riley, PO ;
Pieper, C .
CLINICAL BIOMECHANICS, 1996, 11 (03) :153-158