Multislice CT of the pelvis: dose reduction with regard to image quality using 16-row CT

被引:41
作者
Gurung, J
Khan, MF
Maataoui, A
Herzog, C
Bux, R
Bratzke, H
Ackermann, H
Vogl, TJ
机构
[1] Univ Frankfurt, Inst Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
[2] Univ Frankfurt, Inst Med Stat & Epidemiol, D-60590 Frankfurt, Germany
[3] Univ Frankfurt, Inst Forens Med, D-60590 Frankfurt, Germany
关键词
16-row MDCT; dose reduction; image quality; pelvis;
D O I
10.1007/s00330-005-2720-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To optimize examination protocols of 16-row multi-detector CT (MDCT) of pelvis for dose reduction with regard to image quality. MDCT of pelvis was performed on 12 cadaver specimens with stepwise reduction of tube current from 160 mA (113, 80, 56, 40, 28) to 20 mA at 120 kV. Scan parameters were 16x1.5 mm collimation. Reconstructions of axial and coronal images were used for evaluation of cortex, trabeculum, image quality, image noise, acetabulum and iliosacral (ISJ) joints. After data were blinded, evaluation of images was done by three radiologists according to 5-point Likert scale. Accuracy of the observers in sorting films according to dose reduction was determined with kappa coefficient. Mean values of image evaluation were determined. Pronounced deterioration of image quality for all criteria was observed between 80 and 28 mA. Adequate image quality was obtained at 40 mA [effective dose (E): 2.2 mSv, CTDIw: 2.8 mGy] for criterion detailed definition of acetabulum and ISJ and at 80 mA (E: 4.4 mSv, CTDIw: 5.6 mGy) for remaining criteria. Moderate agreement was observed between the three observers (kappa coefficient: 0.31). All observers were excellent in arranging images according to decreasing dose. Using 16-row MDCT image quality of pelvis is acceptable at 80 mA and 120 kV. This translates into a dose reduction of 33% of average value of the nationwide survey of the German Roentgen Society (1999) for this type of examination.
引用
收藏
页码:1898 / 1905
页数:8
相关论文
共 18 条
[1]   Improvement of image quality of multislice spiral CT scans of the head and neck region using a raw data-based multidimensional adaptive filtering (MAF) technique [J].
Baum, U ;
Anders, K ;
Steinbichler, G ;
Lell, M ;
Greess, H ;
Riedel, T ;
Kachelriess, M ;
Kalender, WA ;
Bautz, WA .
EUROPEAN RADIOLOGY, 2004, 14 (10) :1873-1881
[2]  
Bernhardt JU, 1995, Z MED PHYS, V5, P33
[3]   Assessment of a theoretical formalism for dose estimation in CT: an anthropomorphic phantom study [J].
Brix, G ;
Lechel, U ;
Veit, R ;
Truckenbrodt, R ;
Stamm, G ;
Coppenrath, EM ;
Griebel, J ;
Nagel, HD .
EUROPEAN RADIOLOGY, 2004, 14 (07) :1275-1284
[4]  
Cohnen M, 2000, AM J NEURORADIOL, V21, P1654
[5]   Pulmonary nodules: Experimental and clinical studies at low-dose CT [J].
Diederich, S ;
Lenzen, H ;
Windmann, R ;
Puskas, Z ;
Yelbuz, TM ;
Henneken, S ;
Klaiber, T ;
Eameri, M ;
Roos, N ;
Peters, PE .
RADIOLOGY, 1999, 213 (01) :289-298
[6]   Computed tomography practice Germany - Results of a national survey in 1999 - Preface [J].
Galanski, M ;
Nagel, HD ;
Stamm, G .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (10) :R1-R1
[7]   Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation [J].
Greess, H ;
Lutze, J ;
Nömayr, A ;
Wolf, H ;
Hothorn, T ;
Kalender, WA ;
Bautz, W .
EUROPEAN RADIOLOGY, 2004, 14 (06) :995-999
[8]   Traumatic injuries of the pelvis and thoracic and lumbar spine: does thin-slice multidetector-row CT increase diagnostic accuracy? [J].
Herzog, C ;
Ahle, H ;
Mack, MG ;
Maier, B ;
Schwarz, W ;
Zangos, S ;
Jacobi, V ;
Thalhammer, A ;
Peters, J ;
Ackermann, H ;
Vogl, TJ .
EUROPEAN RADIOLOGY, 2004, 14 (10) :1751-1760
[9]   RADIATION-DOSE REDUCTION IN CT OF THE PEDIATRIC PELVIS [J].
KAMEL, IR ;
HERNANDEZ, RJ ;
MARTIN, JE ;
SCHLESINGER, AE ;
NIKLASON, LT ;
GUIRE, KE .
RADIOLOGY, 1994, 190 (03) :683-687
[10]   CT OF SACRAL INJURY [J].
MONTANA, MA ;
RICHARDSON, ML ;
KILCOYNE, RF ;
HARLEY, JD ;
SHUMAN, WP ;
MACK, LA .
RADIOLOGY, 1986, 161 (02) :499-503