Orthogonal gas sensor arrays by chemoresistive material design

被引:39
作者
Pineau, Nicolay J. [1 ]
Kompalla, Julia F. [1 ]
Guntner, Andreas T. [1 ]
Pratsinis, Sotiris E. [1 ]
机构
[1] Swiss Fed Inst Technol, Particle Technol Lab, Dept Mech & Proc Engn, CH-8092 Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
Gas sensor; Ethanol; Acetone; Ammonia; SnO2; MoO3; WO3; Flame spray pyrolysis; Electronic nose; ELECTRONIC NOSE; BREATH ACETONE; ISOPRENE; DISCRIMINATION; FORMALDEHYDE; AMMONIA; MODEL;
D O I
10.1007/s00604-018-3104-z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gas sensor arrays often lack discrimination power to different analytes and robustness to interferants, limiting their success outside of research laboratories. This is primarily due to the widely sensitive (thus weakly-selective) nature of the constituent sensors. Here, the effect of orthogonality on array accuracy and precision by selective sensor design is investigated. Therefore, arrays of (2-5) selective and non-selective sensors are formed by systematically altering array size and composition. Their performance is evaluated with 60 random combinations of ammonia, acetone and ethanol at ppb to low ppm concentrations. Best analyte predictions with high coefficients of determination (R-2) of 0.96 for ammonia, 0.99 for acetone and 0.88 for ethanol are obtained with an array featuring high degree of orthogonality. This is achieved by using distinctly selective sensors (Si:MoO3 for ammonia and Si:WO3 for acetone together with Si:SnO2) that improve discrimination power and stability of the regression coefficients. On the other hand, arrays with collinear sensors (Pd:SnO2, Pt:SnO2 and Si:SnO2) hardly improve gas predictions having R-2 of 0.01, 0.86 and 0.28 for ammonia, acetone and ethanol, respectively. Sometimes they even exhibited lower coefficient of determination than single sensors as a Si:MoO3 sensor alone predicts ammonia better with a R-2 of 0.68Conventional arrays (red) with weakly-selective sensors span a significantly smaller volume in the analyte space than arrays containing distinctly-selective sensors (orthogonal array, green). Orthogonal arrays feature better accuracy and precision than conventional arrays in mixtures of ammonia, acetone and ethanol.
引用
收藏
页数:9
相关论文
共 35 条
[1]   Measuring Breath Acetone for Monitoring Fat Loss: Review [J].
Anderson, Joseph C. .
OBESITY, 2015, 23 (12) :2327-2334
[2]   CHEMOMETRIC ANALYSIS OF MULTISENSOR ARRAYS [J].
CAREY, WP ;
BEEBE, KR ;
SANCHEZ, E ;
GELADI, P ;
KOWALSKI, BR .
SENSORS AND ACTUATORS, 1986, 9 (03) :223-234
[3]   Quantitative analysis of ammonia on the breath of patients in end-stage renal failure [J].
Davies, S ;
Spanel, P ;
Smith, D .
KIDNEY INTERNATIONAL, 1997, 52 (01) :223-228
[4]   Time variation of ammonia, acetone, isoprene and ethanol in breath: a quantitative SIFT-MS study over 30 days [J].
Diskin, AM ;
Spanel, P ;
Smith, D .
PHYSIOLOGICAL MEASUREMENT, 2003, 24 (01) :107-119
[5]   Enhancing electronic nose performance by sensor selection using a new integer-based genetic algorithm approach [J].
Gardner, JW ;
Boilot, P ;
Hines, EL .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 106 (01) :114-121
[7]   Noninvasive Body Fat Burn Monitoring from Exhaled Acetone with Si-doped WO3-sensing Nanoparticles [J].
Guentner, A. T. ;
Sievi, N. A. ;
Theodore, S. J. ;
Gulich, T. ;
Kohler, M. ;
Pratsinis, S. E. .
ANALYTICAL CHEMISTRY, 2017, 89 (19) :10578-10584
[8]   Selective sensing of NH3 by Si-doped α-MoO3 for breath analysis [J].
Guentner, Andreas T. ;
Righettoni, Marco ;
Pratsinis, Sotiris E. .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 223 :266-273
[9]   Selective sensing of isoprene by Ti-doped ZnO for breath diagnostics [J].
Guntner, A. T. ;
Pineau, N. J. ;
Chie, D. ;
Krumeich, F. ;
Pratsinis, S. E. .
JOURNAL OF MATERIALS CHEMISTRY B, 2016, 4 (32) :5358-5366
[10]   Sniffing Entrapped Humans with Sensor Arrays [J].
Guntner, Andreas T. ;
Pineau, Nicolay J. ;
Mochalski, Pawel ;
Wiesenhofer, Helmut ;
Agapiou, Agapios ;
Mayhew, Christopher A. ;
Pratsinis, Sotiris E. .
ANALYTICAL CHEMISTRY, 2018, 90 (08) :4940-4945