Initial studies on proton computed tomography using a silicon strip detector telescope

被引:31
作者
Johnson, L
Keeney, B
Ross, G
Sadrozinski, HFW [1 ]
Seiden, A
Williams, DC
Zhang, L
Bashkirov, V
Schulte, RW
Shahnazi, K
机构
[1] Univ Calif Santa Cruz, Santa Cruz Inst Particle Phys, Santa Cruz, CA 95064 USA
[2] Loma Linda Univ, Med Ctr, Loma Linda, CA 92354 USA
关键词
proton CT; silicon detectors;
D O I
10.1016/j.nima.2003.08.108
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report initial results of a feasibility study of Proton Computed Tomography and Proton Transmission Radiography for applications in proton therapy treatment planning and patient positioning. The aim of the study is to explore experimentally if PCT, which is based on the measurement of the specific energy loss of protons traversing tissues of different density, may be preferred to X-ray Computed Tomography and X-ray radiography, which are presently used for radiation treatment planning and patient positioning in proton treatment centers. We present first data from proton transmission studies through a hollow aluminum cylinder taken with a telescope of silicon detectors with very high spatial and good energy resolution. In addition, we report the results of GEANT4 simulations of proton transport through the same object, which show good agreement with experimental results and explain the observed features of the proton transmission image. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:215 / 223
页数:9
相关论文
共 9 条
[1]  
Bichsel H., 1972, PASSAGE CHARGED PART
[2]  
Groom DE, 2000, EUR PHYS J C, V15, P1
[3]   An amplifier-discriminator chip for the GLAST silicon-strip tracker [J].
Johnson, RP ;
Poplevin, P ;
Sadrozinski, HFW ;
Spencer, EN .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) :927-930
[4]   A silicon telescope for applications in nanodosimetry [J].
Keeney, B ;
Bashkirov, V ;
Johnson, RP ;
Kroeger, W ;
Ohyama, H ;
Sadrozinski, HFW ;
Schulte, RWM ;
Seiden, A ;
Spradlin, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (04) :1724-1727
[5]  
*NAT I STAND TECHN, PSTAR DAT
[6]   PROTON RADIOGRAPHY AS A TOOL FOR QUALITY-CONTROL IN PROTON THERAPY [J].
SCHNEIDER, U ;
PEDRONI, E .
MEDICAL PHYSICS, 1995, 22 (04) :353-363
[7]   Results from the beam test of the engineering model of the GLAST large area telescope [J].
Couto e Silva, E.do ;
Anthony, P. ;
Arnold, R. ;
Arrighi, H. ;
Bloom, E. ;
Baughman, B. ;
Bogart, J. ;
Bosted, P. ;
Bumala, B. ;
Chekhtman, A. ;
Cotton, N. ;
Crider, A. ;
Dobbs-Dixon, I. ;
Djannati-Atai, A. ;
Dubois, R. ;
Engovatov, D. ;
Espigat, P. ;
Evans, J.L. ;
Fieguth, T. ;
Flath, D. ;
Frigaard, M. ;
Giebels, B. ;
Gillespie, S. ;
Godfrey, G. ;
Grove, J.E. ;
Handa, T. ;
Hansl-Kozanecka, T. ;
Hernando, J. ;
Hicks, M. ;
Hirayama, M. ;
Johnson, W.N. ;
Johnson, R. ;
Kamae, T. ;
Kroeger, W. ;
Lauben, D. ;
Lin, Y.C. ;
Lindner, T. ;
Michelson, P. ;
Moiseev, A. ;
Nikolaou, M. ;
Nolan, P. ;
Odian, A. ;
Ohsugi, T. ;
Ormes, J. ;
Paliaga, G. ;
Parkinson, P.Saz ;
Phlips, B. ;
Ritz, S. ;
Rock, S. ;
Russel, J.J. .
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2001, 474 (01) :19-37
[8]  
*SLAC, 2002, GEANT4 WORKSH SLAC F
[9]   THE PROTON TREATMENT CENTER AT LOMA-LINDA-UNIVERSITY-MEDICAL-CENTER - RATIONALE FOR AND DESCRIPTION OF ITS DEVELOPMENT [J].
SLATER, JM ;
ARCHAMBEAU, JO ;
MILLER, DW ;
NOTARUS, MI ;
PRESTON, W ;
SLATER, JD .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 22 (02) :383-389