Accuracy of a titanium maxillary complete denture baseplate fabricated by using the electron beam melting technique: An in vitro study

被引:2
作者
Asakura, Masaki [1 ]
Ueno, Atsuko [2 ]
Hayashi, Tatsuhide [1 ]
Kawai, Tatsushi [1 ]
机构
[1] Aichi Gakuin Univ, Dept Dent Mat Sci, Sch Dent, Nagoya, Aichi, Japan
[2] Aichi Gakuin Univ, Dept Gerodontol & Home Care Dent, Sch Dent, Nagoya, Aichi, Japan
关键词
RESIDUAL-STRESSES; DESIGN;
D O I
10.1016/j.prosdent.2021.08.004
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Electron beam melting (EBM) is a promising additive manufacturing technique for fabricating denture baseplates; however, studies evaluating its accuracy are sparse. Purpose. The purpose of this in vitro study was to compare the fit accuracy of titanium maxillary complete denture baseplates fabricated by using the EBM technique with those fabricated by using the conventional casting technique and to evaluate the dimensional accuracy of the EBM baseplate by using a 3-dimensional inspection software program. Material and methods. Definitive casts of an edentulous maxilla were prepared. After the casts were optically scanned, computer-aided designs for the EBM baseplate were created by using a software program for standard tessellation language file editing. The EBM baseplates were fabricated with an EBM machine by using a Grade II titanium powder as the raw material. The cast baseplates were fabricated with a lost-wax casting technique by using refractory casts duplicated from the definitive casts. After fitting the EBM and cast baseplates to their corresponding definitive cast, they were embedded in a Type IV stone. The embedded baseplates on the casts were sectioned at 3 regions: posterior palatal seal, molar, and premolar. The maximum gaps between the baseplate and definitive cast were measured in these 3 regions. The virtual casts obtained by scanning the EBM baseplate were superimposed on the computer-aided design to evaluate the dimensional accuracy. Distribution color maps were then generated, and the mean absolute deviations and root mean square deviations were calculated. One-way analysis of variance and t tests were used for statistical analysis (alpha=.05). Results. No significant differences in the maximum gaps among the 3 regions were found in the cast or EBM baseplate groups (P>.05). The EBM baseplate group showed significantly lower values than the cast baseplate group in all regions (premolar: P=.008; molar: P=.003; posterior palatal seal: P=.004). The mean maximum gap for the 3 regions in the cast baseplates was 168.0 mm and that in the EBM baseplates was 60.7 mm. The distribution color map of the EBM baseplate showed a favorable dimensional accuracy. The mean absolute deviation value was 19.7 mm, and the root mean square deviation value was 25.1 mu m. Conclusions. The EBM baseplates had a significantly higher fit accuracy than the cast baseplates. Thus, the fit accuracy of the EBM technique is suitable for fabricating metal baseplates.
引用
收藏
页码:710.e1 / 710.e7
页数:7
相关论文
共 18 条
[1]   Additive Manufacturing Techniques in Prosthodontics: Where Do We Currently Stand? A Critical Review [J].
Alharbi, Nawal ;
Wismeijer, Daniel ;
Osman, Reham B. .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2017, 30 (05) :474-484
[2]   Accuracy of CAD-CAM-fabricated removable partial dentures [J].
Arnold, Christin ;
Hey, Jeremias ;
Schweyen, Ramona ;
Setz, Juergen M. .
JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (04) :586-592
[3]  
Bhavar V, 2017, SYST INNOV SER, P251
[4]   Adaptation of removable partial denture frameworks fabricated by selective laser melting [J].
Chen, Hu ;
Li, Hong ;
Zhao, Yijiao ;
Zhang, Xinyue ;
Wang, Yong ;
Lyu, Peijun .
JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (03) :316-324
[5]   Assessing the Accuracy of Casting and Additive Manufacturing Techniques for Fabrication of a Complete Palatal Coverage Metal Framework [J].
Forrester, Keaton ;
Sheridan, Ryan ;
Phoenix, Rodney D. .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (07) :811-817
[6]   RESIDUAL STRESS MEASUREMENTS AND STRUCTURAL INTEGRITY IMPLICATIONS FOR SELECTIVE LASER MELTED TI-6AL-4V [J].
Knowles, C. R. ;
Becker, T. H. ;
Tait, R. B. .
SOUTH AFRICAN JOURNAL OF INDUSTRIAL ENGINEERING, 2012, 23 (03) :119-129
[7]   Accuracy of a digital removable partial denture fabricated by casting a rapid prototyped pattern: A clinical study [J].
Lee, Jong-Won ;
Park, Ji-Man ;
Park, Eun-Jin ;
Heo, Seong-Joo ;
Koak, Jai-Young ;
Kim, Seong-Kyun .
JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (04) :468-474
[8]   Residual stresses in selective laser sintering and selective laser melting [J].
Mercelis, Peter ;
Kruth, Jean-Pierre .
RAPID PROTOTYPING JOURNAL, 2006, 12 (05) :254-265
[9]  
Revilla-León M, 2019, INT J COMPUT DENT, V22, P55
[10]   Residual stress within metallic model made by selective laser melting process [J].
Shiomi, M ;
Osakada, K ;
Nakamura, K ;
Yamashita, T ;
Abe, F .
CIRP ANNALS-MANUFACTURING TECHNOLOGY, 2004, 53 (01) :195-198