Comparison of Actigraphic and Subjective Measures of Sleep in Implantable Cardioverter Defibrillator and Coronary Artery Disease Patients

被引:12
作者
Cross, Natalie J. [1 ]
McCrae, Christina S. [2 ]
Smith, Karen M. [3 ]
Conti, Jamie B. [3 ]
Sears, Samuel F. [4 ]
机构
[1] Greenville Community Based Outpatient Clin, Dept Vet Affairs, Greenville, NC 27858 USA
[2] Univ Florida, Dept Clin & Hlth Psychol, Gainesville, FL USA
[3] Univ Florida, Div Cardiovasc Med, Gainesville, FL USA
[4] E Carolina Univ, Dept Psychol, Greenville, NC 27858 USA
关键词
RISK-FACTOR; DEPRESSION; ANXIETY; DURATION; POLYSOMNOGRAPHY; QUESTIONNAIRE; ARRHYTHMIAS; IMPACT; WOMEN; SCALE;
D O I
10.1002/clc.20827
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Cardiac patients frequently have insomnia symptoms that may pose risk for future cardiac events. Poor sleep relates to hyperarousal, anxiety and depression, and the incidence of hypertension and myocardial infarction. Hypothesis: The authors hypothesized that implantable cardioverter defibrillator (ICD) patients would have poorer sleep than coronary artery disease (CAD) patients related to hypervigilance for device functioning and shock discharge. Methods: Authors investigated sleep efficiency and sleep latency in a sample of 60 patients (n = 30 CAD and n = 30 ICD) without obstructive sleep apnea at the University of Florida & Shands Hospital. For 14 days, participants completed a sleep diary. Additionally, half of the total sample also used actigraphy to objectively measure their sleep. Measures of somatic hypervigilance and psychosocial distress were administered. Results: Using actigraphy, mean sleep efficiency was poorer (69.76%) in CAD patients compared with ICD patients (82.80%). This difference was highly significant, F(1,27) = 16.840, P < 0.001. CAD patients also had shorter mean total sleep times per sleep diaries compared with ICD patients (336.19 minutes or 5.60 hours, 430.65 minutes or 7.18 hours, respectively), F(1,27) = 15.908, P < 0.001. Conclusions: The finding that ICD patients slept more efficiently than CAD patients is surprising given that CAD patients had higher ejection fractions and no concerns about ICD shocks. This difference cannot be accounted for by differences in hypervigilance, depression, anxiety, or physical activity. Results suggest that CAD patients may have more sleep problems and may warrant increased research attention.
引用
收藏
页码:753 / 759
页数:7
相关论文
共 50 条
  • [21] Driving restrictions for Dutch patients with an implantable cardioverter defibrillator
    Jongejan, N.
    Timmermans, I.
    Elders, J.
    Meijer, K.
    Meine, M.
    Doevendans, P. A.
    Versteeg, H.
    Tuinenburg, A. E.
    NETHERLANDS HEART JOURNAL, 2018, 26 (02) : 69 - 75
  • [22] Anxiety and Depression in Patients with an Implantable Cardioverter Defibrillator and Their Partners: A Longitudinal Study
    Van den Broek, Krista C.
    Heijmans, Naomi
    Van Assen, Marcel A. L. M.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2013, 36 (03): : 362 - 371
  • [23] Trajectories of Perceived Emotional and Physical Distress in Patients with an Implantable Cardioverter Defibrillator
    Krista C. van den Broek
    Nina Kupper
    Pepijn H. van der Voort
    Marco Alings
    Johan Denollet
    Ivan Nyklíček
    International Journal of Behavioral Medicine, 2014, 21 : 149 - 159
  • [24] Neuropsychological impact of implantable cardioverter defibrillator in congestive heart failure patients
    Feola, Mauro
    Vallauri, Paola
    Salvatico, Luigi
    Vado, Antonello
    Testa, Marzia
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 166 (01) : 275 - 276
  • [25] Implantable cardioverter defibrillator therapy in chronic kidney disease: a meta-analysis
    Korantzopoulos, Panagiotis
    Liu, Tong
    Li, Lijian
    Goudevenos, John A.
    Li, Guangping
    EUROPACE, 2009, 11 (11): : 1469 - 1475
  • [26] Anxiety and depression in patients with an implantable cardioverter defibrillator: Do personality and ICD expectations play a role?
    Pedersen, S. S.
    Johansen, J. B.
    Nielsen, J. C.
    Larroude, C. E.
    Riahi, S.
    Melchior, T. M.
    Vinther, M.
    Skovbakke, S. J.
    Skov, O.
    GENERAL HOSPITAL PSYCHIATRY, 2025, 94 : 145 - 149
  • [27] Evaluation of an education and follow-up programme for implantable cardioverter defibrillator-implanted patients
    Cinar, Fatma I.
    Tosun, Nuran
    Kose, Sedat
    JOURNAL OF CLINICAL NURSING, 2013, 22 (17-18) : 2474 - 2486
  • [28] Prevalence and Persistence of Depression in Patients with Implantable Cardioverter Defibrillator: A 2-year Longitudinal Study
    Suzuki, Tsuyoshi
    Shiga, Tsuyoshi
    Kuwahara, Kazue
    Kobayashi, Sayaka
    Suzuki, Shinichi
    Nishimura, Katsuji
    Suzuki, Atsushi
    Ejima, Koichiro
    Manaka, Tetsuyuki
    Shoda, Morio
    Ishigooka, Jun
    Kasanuki, Hiroshi
    Hagiwara, Nobuhisa
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (12): : 1455 - 1461
  • [29] Prevalence of anxiety and risk associated with ventricular arrhythmia in patients with an implantable cardioverter defibrillator
    Habibovic, M.
    Pedersen, S. S.
    Broers, E. R.
    Alings, M.
    Theuns, D. A. M. J.
    van Der Voort, P. H.
    Bouwels, L.
    Herrman, J-P
    Denollet, J.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2020, 310 : 80 - 85
  • [30] Predictors of Quality of Life, Anxiety and Acceptance in Patients with Implantable Cardioverter-Defibrillator
    Silva, Laisa Arruda
    Silva, Katia Regina
    Saucedo, Sarah Caroline Martins
    Costa, Roberto
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2024, 121 (04)