A Novel Magnetic Fluid Based All-Fiber-Optic Vector Magnetometer

被引:0
|
作者
Yin, Jinde [1 ]
Ruan, Shuangchen [1 ]
Liu, Tiegen [2 ]
Jiang, Junfeng [2 ]
Wang, Shuang [2 ]
Yan, Peiguang [1 ]
机构
[1] Shenzhen Univ, Coll Optoelect Engn, Shenzhen Key Lab Laser Engn, Shenzhen 518060, Peoples R China
[2] Tianjin Univ, Key Lab Optoelect Informat Technol, Minist Educ, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Nano-magnetic fluid materials; Photonic crystal fiber; All-optical devices; vector magnetometer; FIELD SENSOR; MICROFIBER;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We demonstrate a compact all-fiber-optic vector magnetometer based on Mach-Zehnder interferometer by utilizing magnetic fluid filled double-clad photonic crystal fiber (DC-PCF). The magnetic fluid (MF) serving as crucial sensing elements is injected into the micro-channel-arrays of DC-PCF. The magnetometer is constructed by splicing a section of MF-filled DC-PCF between two standard single mode fibers forming a high stable all-fiber structure without any additional sealed capillary. The vector magnetometer has the capability of simultaneous measurement of magnetic field intensity and orientation by monitoring a specific dip wavelength shift or transmission loss of Mach-Zehnder interference spectrum. The magnetometer with response sensitivities of 114.5 pm/mT, 1.79 dB/mT (X-axis) and 41.9 pm/mT, 0.52 dB/mT (Y-axis) at two orthogonal magnetic field orientations was fabricated and investigated.
引用
收藏
页数:3
相关论文
共 50 条
  • [21] An all-fiber-optic endoscopy platform for simultaneous OCT and fluorescence imaging
    Mavadia, Jessica
    Xi, Jiefeng
    Chen, Yongping
    Li, Xingde
    BIOMEDICAL OPTICS EXPRESS, 2012, 3 (11): : 2851 - 2859
  • [22] Diode-pumped all-fiber-optic liquid dye laser
    Vladev, V. P.
    Todorova, M. M.
    Brazkova, M. S.
    Bozhkov, S., I
    LASER PHYSICS LETTERS, 2021, 18 (11)
  • [23] All Fiber Vector Magnetometer Based on Nitrogen-Vacancy Center
    Zhao, Man
    Lin, Qijing
    Meng, Qingzhi
    Shan, Wenjun
    Zhu, Liangquan
    Chen, Yao
    Liu, Tao
    Zhao, Libo
    Jiang, Zhuangde
    NANOMATERIALS, 2023, 13 (05)
  • [24] ALL-FIBER-OPTIC GYROSCOPE WITH LINEAR SCALE FACTOR USING PHASE DETECTION
    KIM, BY
    SHAW, HJ
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1984, 478 : 142 - 148
  • [25] ALL-FIBER-OPTIC REMOTE-SENSING OF TEMPERATURE EMPLOYING INTERFEROMETRIC TECHNIQUES
    LEILABADY, PA
    CORKE, M
    OPTICS LETTERS, 1987, 12 (10) : 772 - 774
  • [26] ALL-FIBER-OPTIC POLARIZATION STATE AZIMUTH CONTROL - APPLICATION TO FARADAY-ROTATION
    TATAM, RP
    HILL, DC
    JONES, JDC
    JACKSON, DA
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 1988, 6 (07) : 1171 - 1176
  • [27] Integrated all-fiber-optic sensor based on FPI and MZI composite structures for temperature and strain measurement
    Liu, Yinggang
    Xu, Xinyi
    Zhou, Rui
    Li, Rui
    Li, Fei
    Optik, 2024, 319
  • [28] AN ANALYSIS OF A FIBER-OPTIC MAGNETOMETER WITH MAGNETIC FEEDBACK
    KOO, KP
    DANDRIDGE, A
    BUCHOLTZ, F
    TVETEN, AB
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 1987, 5 (12) : 1680 - 1685
  • [29] A Sensitivity-enhanced All-fiber-optic Liquid Refractive Index Sensor Based on Vernier Effect
    Zhao Yu-xin
    Jiang Jiu-xing
    Yang Yu-qiang
    Wang Yong-guang
    Lu Jian-da
    Liu Jia-cheng
    ACTA PHOTONICA SINICA, 2019, 48 (11)
  • [30] An All-Fiber Magnetic Field Sensor Based on Dual-S-Shaped Optic Fiber Integrated With Magnetic Fluid
    Lei, Xueqin Q.
    Peng, Baojin J.
    Chen, Daru R.
    Shi, Qingguo G.
    Ma, Xiaowei W.