Comparison of Gap Balancing vs Measured Resection Technique in Patients Undergoing Simultaneous Bilateral Total Knee Arthroplasty: One Technique per Knee

被引:21
作者
Tapasvi, Sachin R. [1 ]
Shekhar, Anshu [1 ]
Patil, Shantanu S. [2 ]
Dipane, Matthew V. [3 ]
Chowdhry, Madhav [3 ]
McPherson, Edward J. [3 ]
机构
[1] Orthopaed Specialty Clin, Dept Arthroplasty & Arthroscopy, Pune, Maharashtra, India
[2] SRM Univ, SRM Med Coll & Hosp, Kancheepuram, Tamil Nadu, India
[3] UCLA, David Geffen Sch Med, Dept Orthopaed Surg, 1250 16th St,Suite 3145, Santa Monica, CA 90404 USA
关键词
gap balance; measured resection; primary total knee arthroplasty; surgical technique; femoral component rotation; FEMORAL ROTATIONAL ALIGNMENT; JOINT-LINE MAINTENANCE; MECHANICAL ALIGNMENT; FUNCTIONAL OUTCOMES; COMPONENT ROTATION; TKA; INSTABILITY; POSITION; SYMMETRY; AXIS;
D O I
10.1016/j.arth.2019.10.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Total knee arthroplasty requires careful surgical technique to attain the goal of a well-aligned and symmetrically balanced knee. Soft tissue balance and correct femoral component rotation are paramount in achieving these goals. The two competing techniques to select femoral component rotation and soft tissue balance are the gap balance technique and the measured resection technique. Methods: We performed a randomized, prospective study to compare the two techniques in patients undergoing simultaneous bilateral total knee arthroplasty, whereby one technique was performed in each knee. Fifty (50) subjects were enrolled into the study. The inclusion criteria were osteoarthritic varus knee deformities with similar deformities in both knees. Subjects were followed up for a minimum of two years. Results: The knees balanced via the gap balance technique had significantly more posterior medial bone removed from the femur than those knees balanced via the measured resection technique (P < .001). Knees in the gap balance group tended to require more medial knee releases in extension and tended to have smaller sized femoral components as a result of cutting more bone from the femur in flexion. The modular tibial polyethylene bearing tended to be thicker in the gap balance group. Despite these differences, average knee flexion and functional revised Oxford Knee Scores at 2-year follow-up were not statistically different. Conclusion: At 2-year follow-up, there were no differences between the function and scores using the two techniques. Long-term follow-up will be necessary to evaluate any differences in long-term durability. (c) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:732 / 740
页数:9
相关论文
共 47 条
[1]   Rotational Position of Femoral and Tibial Components in TKA Using the Femoral Transepicondylar Axis [J].
Aglietti, Paolo ;
Sensi, Lorenzo ;
Cuomo, Pierluigi ;
Ciardullo, Antonio .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (11) :2751-2755
[2]   Gap Balancing Sacrifices Joint-Line Maintenance to Improve Gap Symmetry: 5-Year Follow-Up of a Randomized Controlled Trial [J].
Babazadeh, Sina ;
Dowsey, Michelle M. ;
Vasimalla, Michael G. ;
Stoney, James D. ;
Choong, Peter F. M. .
JOURNAL OF ARTHROPLASTY, 2018, 33 (01) :75-78
[3]   Gap Balancing Sacrifices Joint-Line Maintenance to Improve Gap Symmetry: A Randomized Controlled Trial Comparing Gap Balancing and Measured Resection [J].
Babazadeh, Sina ;
Dowsey, Michelle M. ;
Stoney, James D. ;
Choong, Peter F. M. .
JOURNAL OF ARTHROPLASTY, 2014, 29 (05) :950-954
[4]   Malrotation causing patellofemoral complications after total knee arthroplasty [J].
Berger, RA ;
Crossett, LS ;
Jacobs, JJ ;
Rubash, HE .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (356) :144-153
[5]   Patient Satisfaction after Total Knee Arthroplasty Who is Satisfied and Who is Not? [J].
Bourne, Robert B. ;
Chesworth, Bert M. ;
Davis, Aileen M. ;
Mahomed, Nizar N. ;
Charron, Kory D. J. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (01) :57-63
[6]   Gap-Balancing versus Measured Resection Technique in Total Knee Arthroplasty: A Comparison Study [J].
Churchill, Jessica L. ;
Khlopas, Anton ;
Sultan, Assem A. ;
Harwin, Steven F. ;
Mont, Michael A. .
JOURNAL OF KNEE SURGERY, 2018, 31 (01) :13-16
[7]   Intraoperative Comparison of Measured Resection and Gap Balancing Using a Force Sensor: A Prospective, Randomized Controlled Trial [J].
Cidambi, Krishna R. ;
Robertson, Nicholas ;
Borges, Camille ;
Nassif, Nader A. ;
Barnett, Steven L. .
JOURNAL OF ARTHROPLASTY, 2018, 33 (07) :S126-S130
[8]   Gap Balancing vs. Measured Resection Technique in Total Knee Arthroplasty [J].
Daines, Brian K. ;
Dennis, Douglas A. .
CLINICS IN ORTHOPEDIC SURGERY, 2014, 6 (01) :1-8
[9]   Gap Balancing versus Measured Resection Technique for Total Knee Arthroplasty [J].
Dennis, Douglas A. ;
Komistek, Richard D. ;
Kim, Raymond H. ;
Sharma, Adrija .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (01) :102-107
[10]  
Doyle D J., 2018, American Society of Anesthesiologists Classification (ASA Class)