Analysis of intact proteins with capillary zone electrophoresis coupled to mass spectromery using uncoated and coated capillaries

被引:20
作者
Hamidli, N. [1 ]
Andrasi, M. [1 ]
Nagy, C. [1 ]
Gaspar, A. [1 ]
机构
[1] Univ Debrecen, Dept Inorgan & Analyt Chem, Egyet Ter 1, H-4032 Debrecen, Hungary
关键词
Intact proteins; Capillary electrophoresis; Mass spectrometry; Top-down; Polybrene; Linear polyacrylamide; Bare fused silica; TOP-DOWN CHARACTERIZATION; COATINGS; SEPARATION; PROTEOMICS; COMPLEXES; TIME;
D O I
10.1016/j.chroma.2021.462448
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Although, in general, the application of coated capillaries is recommended for the separation of intact proteins, bare silica capillary is still the most often used capillary due to its simplicity and cheapness. In this work, the performance of bare fused silica capillary for intact protein analysis was compared to that of different (dynamically coated polybrene (PB) and permanently coated linear polyacrylamide (LPA)) coated capillaries using capillary zone electrophoresis mass spectrometry (CZE-MS). In cases where low pH (pH = 1.8) was used in bare silica capillaries, good precision (0.56-0.78 RSD% and 1.7-6.5 RSD% for migration times and peak areas, respectively), minimal adsorption and separation efficiency (N = 27 0 0 0/m 322 0 0 0/m) similar to or even better than those obtained with the coated capillaries (created by an intricate multi-step process) was achieved. The PB and the LPA capillaries demonstrated their slightly better resolving power in terms of separating the different forms/variants of the same protein (e.g., hemoglobin subunits). Among the studied capillaries the one with LPA coating showed the most stable separations in the long term (n = 25: 0.18-0.49 RSD% and 3.1-4.9 RSD% for migration times and peak areas, respectively). For the separation of a few proteins or even a larger number of proteins in biological samples (e.g., snake venom) the application of the simple and cheap bare fused silica capillary can be considered as an efficient choice. (c) 2021 The Author(s). Published by Elsevier B.V. This is an open access article under the CC BY license ( http://creativecommons.org/licenses/by/4.0/ )
引用
收藏
页数:9
相关论文
共 40 条
[1]   Determination of deamidated isoforms of human insulin using capillary electrophoresis [J].
Andrasi, M. ;
Pajaziti, B. ;
Sipos, B. ;
Nagy, C. ;
Hamidli, N. ;
Gaspar, A. .
JOURNAL OF CHROMATOGRAPHY A, 2020, 1626
[2]  
[Anonymous], 1996, CAPILLARY ELECTROPHO
[3]   Glycoprotein characterization combining intact protein and glycan analysis by capillary electrophoresis-electrospray ionization-mass spectrometry [J].
Balaguer, Elvira ;
Neusuess, Christian .
ANALYTICAL CHEMISTRY, 2006, 78 (15) :5384-5393
[4]   Intact glycoform characterization of erythropoietin-α and erythropoietin-β by CZE-ESI-TOF-MS [J].
Balaquer, E. ;
Neususs, C. .
CHROMATOGRAPHIA, 2006, 64 (5-6) :351-357
[5]   A fully automated linear polyacrylamide coating and regeneration method for capillary electrophoresis of proteins [J].
Bodnar, Judit ;
Hajba, Laszlo ;
Guttman, Andras .
ELECTROPHORESIS, 2016, 37 (23-24) :3154-3159
[6]   High Resolution CZE-MS Quantitative Characterization of Intact Biopharmaceutical Proteins: Proteoforms of Interferon-β1 [J].
Bush, David R. ;
Zang, Li ;
Belov, Arseniy M. ;
Ivanov, Alexander R. ;
Kargert, Barry L. .
ANALYTICAL CHEMISTRY, 2016, 88 (02) :1138-1146
[7]   Intact protein separation by chromatographic and/or electrophoretic techniques for top-down proteomics [J].
Capriotti, Anna Laura ;
Cavaliere, Chiara ;
Foglia, Patrizia ;
Samperi, Roberto ;
Lagana, Aldo .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (49) :8760-8776
[8]   Top Down proteomics: Facts and perspectives [J].
Catherman, Adam D. ;
Skinner, Owen S. ;
Kelleher, Neil L. .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2014, 445 (04) :683-693
[9]   Simplifying capillary electrophoresis-mass spectrometry operation: Eliminating capillary derivatization by using self-coating background electrolytes [J].
Garza, Selynda ;
Chang, Silvia ;
Moini, Mehdi .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1159 (1-2) :14-21
[10]   Static coatings for the analysis of intact monoclonal antibody drugs by capillary zone electrophoresis [J].
Gassner, Anne-Laure ;
Rudaz, Serge ;
Schappler, Julie .
ELECTROPHORESIS, 2013, 34 (18) :2718-2724