Major determinants for the uncovered stent struts on optical coherence tomography after drug-eluting stent implantation

被引:15
|
作者
Kim, Byeong-Keuk [1 ]
Kim, Jung-Sun [1 ]
Oh, Changmyung [1 ]
Ko, Young-Guk [1 ]
Choi, Donghoon [1 ]
Jang, Yangsoo [1 ,2 ]
Hong, Myeong-Ki [1 ,2 ]
机构
[1] Yonsei Univ, Coll Med, Div Cardiol, Severance Cardiovasc Hosp, Seoul 120752, South Korea
[2] Yonsei Univ, Coll Med, Severance Biomed Sci Inst, Seoul 120752, South Korea
来源
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING | 2012年 / 28卷 / 04期
关键词
Optical coherence tomography; Stent; ELEVATION MYOCARDIAL-INFARCTION; TERM-FOLLOW-UP; NEOINTIMAL COVERAGE; INTRAVASCULAR ULTRASOUND; STABLE ANGINA; THROMBOSIS; MALAPPOSITION;
D O I
10.1007/s10554-011-9896-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
There have been little data regarding major determinants for the uncovered stent struts after drug-eluting stent (DES) implantation on optical coherence tomography (OCT). We investigated the major determinants of incomplete neointimal coverage of DES struts on OCT after implantation in a large cohort of patients. A total of 261 patients with 279 lesions who were treated with various DESs were selected from the OCT registry database. The lesions were divided into two groups based on the ratio of uncovered struts to total struts in all OCT cross-sections; an uncovered group (highest quartile with % uncovered struts a parts per thousand yen5.4%, n = 70), and covered group (the remaining lower quartiles with % uncovered struts < 5.4%, n = 209). The uncovered group was more likely to have complex lesions, smaller reference vessel and stent diameter, and longer stent, more use of sirolimus-eluting stents, and less use of zotarolimus-eluting stents compared with the covered group. Of these variables, the most significant determinant of uncovered stent struts was DES type (odds ratio [OR] = 2.75, 95% confidence interval [CI] = 1.94-3.89, P < 0.001). The use of sirolimus-eluting stents (OR = 2.44, 95% CI, 1.15-5.47, P = 0.023) and zotarolimus-eluting stents (OR = 0.02, 95% CI = 0.01-0.25, P = 0.002) were the only significant risk and protective factors for uncovered stent struts, respectively. This study demonstrated that DES type might be associated with the most important determinants of uncovered struts compared to any other clinical or angiographic factor.
引用
收藏
页码:705 / 714
页数:10
相关论文
共 50 条
  • [1] Major determinants for the uncovered stent struts on optical coherence tomography after drug-eluting stent implantation
    Byeong-Keuk Kim
    Jung-Sun Kim
    Changmyung Oh
    Young-Guk Ko
    Donghoon Choi
    Yangsoo Jang
    Myeong-Ki Hong
    The International Journal of Cardiovascular Imaging, 2012, 28 : 705 - 714
  • [2] Optical coherence tomography derived cut-off value of uncovered stent struts to predict adverse clinical outcomes after drug-eluting stent implantation
    Hoyoun Won
    Dong-Ho Shin
    Byeong-Keuk Kim
    Gary S. Mintz
    Jung-Sun Kim
    Young-Guk Ko
    Donghoon Choi
    Yangsoo Jang
    Myeong-Ki Hong
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1255 - 1263
  • [3] Optical coherence tomography derived cut-off value of uncovered stent struts to predict adverse clinical outcomes after drug-eluting stent implantation
    Won, Hoyoun
    Shin, Dong-Ho
    Kim, Byeong-Keuk
    Mintz, Gary S.
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (06): : 1255 - 1263
  • [4] Optical coherence tomography findings of very late stent thrombosis after drug-eluting stent implantation
    Young-Guk Ko
    Dong-Min Kim
    Jin Man Cho
    So Yeon Choi
    Jung Han Yoon
    Jung-Sun Kim
    Byeong-Keuk Kim
    Donghoon Choi
    Yangsoo Jang
    Myeong-Ki Hong
    The International Journal of Cardiovascular Imaging, 2012, 28 : 715 - 723
  • [5] Optical coherence tomography findings of very late stent thrombosis after drug-eluting stent implantation
    Ko, Young-Guk
    Kim, Dong-Min
    Cho, Jin Man
    Choi, So Yeon
    Yoon, Jung Han
    Kim, Jung-Sun
    Kim, Byeong-Keuk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (04): : 715 - 723
  • [6] Impact of Preprocedural High-Sensitivity C-Reactive Protein Levels on Uncovered Stent Struts: An Optical Coherence Tomography Study After Drug-Eluting Stent Implantation
    Kim, Byeong-Keuk
    Kim, Jung-Sun
    Oh, Changmyung
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    CLINICAL CARDIOLOGY, 2011, 34 (02) : 97 - 101
  • [7] Optical coherence tomography surveillance following drug-eluting stent implantation
    Koppara, T.
    Virmani, R.
    Joner, M.
    MINERVA CARDIOANGIOLOGICA, 2015, 63 (01): : 59 - 74
  • [8] Tissue Characterization After Drug-Eluting Stent Implantation Using Optical Coherence Tomography
    Malle, Caroline
    Tada, Tomohisa
    Steigerwald, Kristin
    Ughi, Giovanni J.
    Schuster, Tibor
    Nakano, Masataka
    Massberg, Steffen
    Jehle, Johannes
    Guagliumi, Giulio
    Kastrati, Adnan
    Virmani, Renu
    Byrne, Robert A.
    Joner, Michael
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2013, 33 (06) : 1376 - +
  • [9] The predictors of neoatherosclerosis after drug-eluting stent implantation evaluated by optical coherence tomography
    Zheng, B. Z.
    Li, S. G. L.
    Chen, M. C.
    EUROPEAN HEART JOURNAL, 2018, 39 : 543 - 543
  • [10] Novel volumetric analysis for stent expansion after drug-eluting stent implantation: An optical coherence tomography study
    Katsura, Aritomo
    Minami, Yoshiyasu
    Kato, Ayami
    Muramatsu, Yusuke
    Sato, Toshimitsu
    Hashimoto, Takuya
    Meguro, Kentaro
    Shimohama, Takao
    Ako, Junya
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 96 (05) : E501 - E507