Identification of Stressors Leading to Degradation of Antisoiling Coating in Warm and Humid Climate Zones

被引:10
作者
Bhaduri, Sonali [1 ,2 ]
Alath, Ajeesh [1 ]
Mallick, Sudhanshu [1 ,3 ]
Shiradkar, Narendra S. [1 ,4 ]
Kottantharayil, Anil [1 ,4 ]
机构
[1] IIT, Natl Ctr Photovolta Res & Educ, Mumbai 400076, Maharashtra, India
[2] IIT, Ctr Res Nanotechnol & Sci, Mumbai 400076, Maharashtra, India
[3] IIT, Dept Met Engn & Mat Sci, Mumbai 400076, Maharashtra, India
[4] Indian Inst Technol, Dept Elect Engn, Mumbai 400076, Maharashtra, India
来源
IEEE JOURNAL OF PHOTOVOLTAICS | 2020年 / 10卷 / 01期
关键词
Acid rain; antisoiling (AS) coating; contact angle; dust; mitigation; photovoltaic (PV) modules; soiling loss; Wilcoxon signed-rank test; STABILITY;
D O I
10.1109/JPHOTOV.2019.2946709
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
We experimentally identified significant stressors that degrade the hydrophobic (contact angle > 90 degrees) antisoiling coatings on exposure to Mumbai weather conditions, where losses due to dust deposition go up to 50% in three months. The contact angle of the antisoiling coatings changed from hydrophobic to hydrophilic (contact angle < 90 degrees) in 12 weeks of field exposure. By testing the weakest performing coating on photovoltaic (PV) modules, no significant reduction of rate of dust deposition was observed on the coated PV module throughout the year. Soiling loss of the coated module went back to zero after every cleaning run (not seen in the uncoated module), which signifies ease of cleaning in the coated module. This resulted in a 2.2% lower soiling loss than the uncoated weekly cleaned module. This trend was reversed after four months of heavy rainfall, after which the uncoated module shows lower soiling loss than the coated module. Signatures of stressors identified by the field exposure test were: 1) rainfall-frequent natural cleaning during rain caused significant abrasion on the coated surface, and the acidic component of the rainfall reacted with the coating (which was verified by the indoor individual stress test), and 2) frequent manual cleaning runs, which lead to abrasion by dust and water (verified by the indoor individual stress test). The effect of frequent cleaning on the field was more severe, as, in real field condition, the combination of stressors acted concurrently. The effect of UV exposure and condensation was also studied by the indoor stress test, where the combination of UV exposure and condensation showed a statistically significant decrease in the contact angle (for all coatings). The rate of decrease in the contact angle was the highest for coating C, making it completely hydrophilic after 32 kWh/m(2) of UV dose and 441 h of condensation. However, in indoor stress tests with individual stressors (UV exposure and water immersion), very high stress levels are required for producing a similar extent of degradation.
引用
收藏
页码:166 / 172
页数:7
相关论文
共 24 条
  • [11] John J. J, 2015, THESIS
  • [12] Fundamental Studies of Adhesion of Dust to PV Module Surfaces: Chemical and Physical Relationships at the Microscale
    Kazmerski, Lawrence L.
    Diniz, Antonia Sonia A. C.
    Maia, Cristiana Brasil
    Viana, Marcelo Machado
    Costa, Suellen C.
    Brito, Pedro P.
    Campos, Claudio Dias
    Macheto Neto, Lauro V.
    Hanriot, Sergio de Morais
    de Oliveira Cruz, Leila R.
    [J]. IEEE JOURNAL OF PHOTOVOLTAICS, 2016, 6 (03): : 719 - 729
  • [13] Antireflective, self-cleaning and protective film by continuous sputtering of a plasma polymer on inorganic multilayer for perovskite solar cells application
    Kim, Mac
    Kang, Tae-Woon
    Kim, Sung Hyun
    Jung, Eui Hyuk
    Park, Helen Hejin
    Seo, Jangwon
    Lee, Sang-Jin
    [J]. SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2019, 191 : 55 - 61
  • [14] Hydrolytic Stability of 3-Aminopropylsilane Coupling Agent on Silica and Silicate Surfaces at Elevated Temperatures
    Okhrimenko, Denis V.
    Budi, Akin
    Ceccato, Marcel
    Cardenas, Marite
    Johansson, Dorte B.
    Lybye, Dorthe
    Bechgaard, Klaus
    Andersson, Martin P.
    Stipp, Susan L. S.
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (09) : 8344 - 8353
  • [15] Comparative analysis of energy produced by photovoltaic modules with anti-soiling coated surface in arid climates
    Piliougine, M.
    Canete, C.
    Moreno, R.
    Carretero, J.
    Hirose, J.
    Ogawa, S.
    Sidrach-de-Cardona, M.
    [J]. APPLIED ENERGY, 2013, 112 : 626 - 634
  • [16] Chemical characterization of precipitation at a coastal site in Trombay, Mumbai, India
    Prathibha, P.
    Kothai, P.
    Saradhi, I. V.
    Pandit, G. G.
    Puranik, V. D.
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2010, 168 (1-4) : 45 - 53
  • [17] The Wilcoxon signed rank test for paired comparisons of clustered data
    Rosner, B
    Glynn, RJ
    Lee, MLT
    [J]. BIOMETRICS, 2006, 62 (01) : 185 - 192
  • [18] SEQUEIRA R, 1976, TELLUS, V28, P275, DOI 10.1111/j.2153-3490.1976.tb00676.x
  • [19] Strauss B., 2019, P 46 IEEE PHOT SPEC
  • [20] Soiling and cleaning: Initial observations from 5-year photovoltaic glass coating durability study
    Toth, Sarah
    Muller, Matthew
    Miller, David C.
    Moutinho, Helio
    To, Bobby
    Micheli, Leonardo
    Linger, Jeffrey
    Engtrakul, Chaiwat
    Einhorn, Asher
    Simpson, Lin
    [J]. SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2018, 185 : 375 - 384