Double-Thyristor-Based Protection for Valve-Side Single-Phase-to-Ground Faults in HB-MMC-Based Bipolar HVDC Systems

被引:37
作者
Li, Gen [1 ]
Liu, Wei [1 ]
Joseph, Tibin [1 ]
Liang, Jun [1 ]
Song, Ziming [2 ]
机构
[1] Cardiff Univ, Sch Engn, Cardiff CF24 3AA, Wales
[2] Toshiba Int Europe Ltd, Uxbridge UB11 1EZ, Middx, England
基金
英国工程与自然科学研究理事会; 欧盟地平线“2020”;
关键词
Circuit faults; Grounding; Thyristors; HVDC transmission; Voltage control; Capacitors; Impedance; Bipolar high-voltage direct-current (HVdc); double-thyristors; modular multilevel converter (MMC) protection; single-phase fault; valve-side fault; LINES; VSC;
D O I
10.1109/TIE.2019.2931502
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The valve-side single-phase-to-ground (SPG) faults in the half-bridge modular multilevel converter (HB-MMC)-based bipolar high-voltage direct-current (HVdc) systems induce some special fault consequences: overvoltage on the submodule (SM) capacitors in converter upper arms and nonzero-crossing currents in the grid-side ac circuit breaker (ACCB). In this letter, a protection strategy based on converter-embedded double-thyristors is proposed to address these issues. The double-thyristors are installed in parallel with each SM in the lower arms of the converter. By triggering the double-thyristors, the SPG fault is converted into a three-phase short-circuit that ensures current zero-crossings in the grid-side ACCB. Moreover, as the voltages of converter ac buses are clamped by the ground through the triggered double-thyristors, the upper arm overvoltage is mitigated. The effectiveness of the proposed protection strategy has been verified in a bipolar HB-MMC HVdc link built in PSCAD/EMTDC.
引用
收藏
页码:5810 / 5815
页数:6
相关论文
共 18 条
[1]  
Andersson G., 2015, PROC HVDC POWER ELEC, P1
[2]  
[Anonymous], 2012, P CIGRE C HVDC POW E
[3]  
[Anonymous], B457 CIGRE MAN HVDC
[4]  
[Anonymous], 2013, P CIGRE CAN C
[5]   HVDC Systems in Smart Grids [J].
Barnes, Mike ;
Van Hertem, Dirk ;
Teeuwsen, Simon P. ;
Callavik, Magnus .
PROCEEDINGS OF THE IEEE, 2017, 105 (11) :2082-2098
[6]  
Ding GJ, 2008, IEEE POW ENER SOC GE, P1767
[7]   Fault Handling at Hybrid High-Voltage AC/DC Transmission Lines With VSC Converters [J].
Ebner, Guenter ;
Doering, David ;
Schettler, Frank ;
Wuerflinger, Klaus ;
Zeller, Marcus .
IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (02) :901-908
[8]   A New Protection Scheme for HVDC Converters Against DC-Side Faults With Current Suppression Capability [J].
Elserougi, Ahmed A. ;
Abdel-Khalik, Ayman S. ;
Massoud, Ahmed M. ;
Ahmed, Shehab .
IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (04) :1569-1577
[9]   Thyristor-Bypassed Submodule Power-Groups for Achieving High-Efficiency, DC Fault Tolerant Multilevel VSCs [J].
Judge, Paul D. ;
Merlin, Michael M. C. ;
Green, Tim C. ;
Trainer, David R. ;
Vershinin, Konstantin .
IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (01) :349-359
[10]   Analysis of Single-Phase-to-Ground Faults at the Valve-Side of HB-MMCs in HVDC Systems [J].
Li, Gen ;
Liang, Jun ;
Ma, Fan ;
Ugalde-Loo, Carlos E. ;
Liang, Haifeng .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2019, 66 (03) :2444-2453