In Vivo Detection of Acinar Microstructural Changes in Early Emphysema with 3He Lung Morphometry

被引:58
作者
Quirk, James D. [1 ]
Lutey, Barbara A. [2 ]
Gierada, David S. [1 ]
Woods, Jason C. [1 ,3 ]
Senior, Robert M. [2 ]
Lefrak, Stephen S. [2 ]
Sukstanskii, Alexander L. [1 ]
Conradi, Mark S. [1 ,3 ]
Yablonskiy, Dmitriy A. [1 ,3 ]
机构
[1] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
[2] Washington Univ, Dept Internal Med, Div Pulm & Crit Care Med, St Louis, MO 63110 USA
[3] Washington Univ, Dept Phys, St Louis, MO 63110 USA
关键词
OBSTRUCTIVE PULMONARY-DISEASE; SCANNING-ELECTRON-MICROSCOPY; HYPERPOLARIZED HE-3; DIFFUSION MRI; COMPUTED-TOMOGRAPHY; MAGNETIC-RESONANCE; FUNCTION TESTS; SMOKERS; HEALTHY; MODEL;
D O I
10.1148/radiol.11102226
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To quantitatively characterize early emphysematous changes in the lung microstructure of current and former smokers with noninvasive helium 3 (He-3) lung morphometry and to compare these results with the clinical standards, pulmonary function testing (PFT) and low-dose computed tomography (CT). Materials and Methods: This study was approved by the local institutional review board, and all subjects provided informed consent. Thirty current and former smokers, each with a minimum 30-pack-year smoking history and mild or no abnormalities at PFT, underwent He-3 lung morphometry. This technique is based on diffusion MR imaging with hyperpolarized 3 He gas and yields quantitative localized in vivo measurements of acinar airway geometric parameters, such as airway radii, alveolar depth, and number of alveoli per unit lung volume. These measurements enable calculation of standard morphometric characteristics, such as mean linear intercept and surface-to-volume ratio. Results: Noninvasive He-3 lung morphometry was used to detect alterations in acinar structure in smokers with normal PFT findings. When compared with smokers with the largest forced expiratory volume in 1 second (FEV1) to forced vital capacity (FVC) ratio, those with chronic obstructive pulmonary disease had significantly reduced alveolar depth (0.07 mm vs 0.13 mm) and enlarged acinar ducts (0.36 mm vs 0.3 mm). The mean alveolar geometry measurements in the healthiest subjects were in excellent quantitative agreement with literature values obtained by using invasive techniques (acinar duct radius, 0.3 mm; alveolar depth, 0.14 mm at 1 L above functional residual capacity). He-3 lung morphometry depicted greater abnormalities than did PFT and CT. No adverse events were associated with inhalation of He-3 gas. Conclusion: He-3 lung morphometry yields valuable noninvasive insight into early emphysematous changes in alveolar geometry with increased sensitivity compared with conventional techniques. (C) RSNA, 2011
引用
收藏
页码:866 / 874
页数:9
相关论文
共 52 条
[51]   Quantitative in vivo assessment of lung microstructure at the alveolar level with hyperpolarized 3He diffusion MRI [J].
Yablonskiy, DA ;
Sukstanskii, AL ;
Leawoods, JC ;
Gierada, DS ;
Bretthorst, GL ;
Lefrak, SS ;
Cooper, JD ;
Conradi, MS .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2002, 99 (05) :3111-3116
[52]   Quantification of lung microstructure with hyperpolarized 3He diffusion MRI [J].
Yablonskiy, Dmitriy A. ;
Sukstanskii, Alexander L. ;
Woods, Jason C. ;
Gierada, David S. ;
Quirk, James D. ;
Hogg, James C. ;
Cooper, Joel D. ;
Conradi, Mark S. .