Assessment of potential relationship between wall shear stress and arterial wall response after bare metal stent and sirolimus-eluting stent implantation in patients with diabetes mellitus

被引:22
作者
Suzuki, Nobuaki [2 ]
Nanda, Hitesh [2 ]
Angiolillo, Dominick J. [2 ]
Bezerra, Hiran [2 ]
Sabate, Manel [3 ]
Jimenez-Quevedo, Pilar
Alfonso, Fernando
Macaya, Carlos
Bass, Theodore A. [2 ]
Ilegbusi, Olusegun J. [4 ]
Costa, Marco A. [1 ,2 ]
机构
[1] Case Western Reserve Univ, Univ Hosp Cleveland, Inst Heart & Vasc, Ctr Res & Innovat, Cleveland, OH 44106 USA
[2] Univ Florida, Div Cardiol & Cardiovasc Imaging Core Labs, Jacksonville, FL USA
[3] Hosp Santa Creu & Sant Pau, Dept Cardiol, Barcelona, Spain
[4] Univ Cent Florida, Coll Engn & Comp Sci, Dept Mat Mech & Aerosp Engn, Cardiovasc Res Lab, Madrid, Spain
关键词
wall shear stress; intravascular ultrasound; drug-eluting stent; diabetes;
D O I
10.1007/s10554-007-9274-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Wall shear stress (WSS) has been associated with neointimal hyperplasia (NIH) following bare metal stent (BMS) implantation. Drug-eluting stents (DES) almost abolish NIH. Conversely, diabetes mellitus amplifies NIH response. The association between WSS and arterial wall response following DES and BMS implantation in diabetic patients remains to be evaluated. Methods The study involved 20 diabetic patients randomized to BMS (n = 9) or sirolimus-eluting stent (SES; n = 11) implantation in native coronary arteries. A computational fluid dynamic model applied 3D intravascular ultrasound (IVUS) and two-plane angiographic to measure WSS (Pa). IVUS assessments were performed post-procedure and at 9-months follow-up. The target segment encompassed the stent plus 5 mm distal and proximal edges. A total of 93 subsegments were evaluated: in-stent segments divided in three subsegments (proximal, mid and distal; n = 60) and, proximal and distal edges (n = 33). Results Stent length was similar between BMS (17.4 +/- 7.3 mm) and SES (19.8 +/- 6.8 mm) groups. NIH was observed in all BMS subsegments (n = 27) versus one subsegment in the SES group (n = 33). WSS ranged from 0.52 to 4.20 Pa in the BMS and from 0.42 to 3.06 Pa in the SES group. There was no correlation between WSS and NIH in either stent group. In addition, there were no correlation between the change of external elastic membrane (EEM) or plaque growth at the edges and WSS. Conclusion WSS was not associated with NIH after implantation of SES or BMS in diabetic patients. Plaque growth or the change of EEM at the edges were not associated with WSS either.
引用
收藏
页码:357 / 364
页数:8
相关论文
共 22 条
[1]   Sirolimus-eluting stents inhibit neointimal hyperplasia in diabetic patients - Insights from the RAVEL Trial [J].
Abizaid, A ;
Costa, MA ;
Blanchard, D ;
Albertal, M ;
Eltchaninoff, H ;
Guagliumi, G ;
Geert-Jan, L ;
Abizaid, AS ;
Sousa, AGMR ;
Wuelfert, E ;
Wietze, L ;
Sousa, JE ;
Serruys, PW ;
Morice, MC .
EUROPEAN HEART JOURNAL, 2004, 25 (02) :107-112
[2]   Randomized comparison of a high clopidogrel maintenance dose in patients with diabetes mellitus and coronary artery disease - Results of the Optimizing antiPlatelet Therapy In diabetes MellitUS (OPTIMUS) study [J].
Angiolillo, Dominick J. ;
Shoemaker, Steven B. ;
Desai, Bhaloo ;
Yuan, Hang ;
Charlton, Ronald K. ;
Bernardo, Esther ;
Zenni, Martin M. ;
Guzman, Luis A. ;
Bass, Theodore A. ;
Costa, Marco A. .
CIRCULATION, 2007, 115 (06) :708-716
[3]   Potential mechanisms promoting restenosis in diabetic patients [J].
Aronson, D ;
Bloomgarden, Z ;
Rayfield, EJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (03) :528-535
[4]   Biochemistry and molecular cell biology of diabetic complications [J].
Brownlee, M .
NATURE, 2001, 414 (6865) :813-820
[5]   Molecular basis of restenosis and drug-eluting stents [J].
Costa, MA ;
Simon, DI .
CIRCULATION, 2005, 111 (17) :2257-2273
[6]   Usefulness of shear stress pattern in predicting neointima distribution in sirolimus-eluting stents in coronary arteries [J].
Gijsen, FJH ;
Oortman, RM ;
Wentzel, JJ ;
Schuurbiers, JCH ;
Tanabe, K ;
Degertekin, M ;
Ligthart, JM ;
Thury, A ;
de Feyter, PJ ;
Serruys, PW ;
Slager, CJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (11) :1325-1328
[7]  
GLAGOV S, 1992, J HYPERTENS, V10, pS101
[8]   INTIMAL HYPERPLASIA, VASCULAR MODELING, AND THE RESTENOSIS PROBLEM [J].
GLAGOV, S .
CIRCULATION, 1994, 89 (06) :2888-2891
[9]   Effects of balloon injury on neointimal hyperplasia in streptozotocin-induced diabetes and in hyperinsulinemic nondiabetic pancreatic islet-transplanted rats [J].
Indolfi, C ;
Torella, D ;
Cavuto, L ;
Davalli, AM ;
Coppola, C ;
Esposito, G ;
Carriero, MV ;
Rapacciuolo, A ;
Di Lorenzo, E ;
Stabile, E ;
Perrino, C ;
Chieffo, A ;
Pardo, F ;
Chiariello, M .
CIRCULATION, 2001, 103 (24) :2980-2986
[10]   Vascular effects of sirolimus-eluting versus bare-metal stents in diabetic patients -: Three-dimensional ultrasound results of the diabetes and sirolimus-eluting stent (DIABETES) trial [J].
Jimenez-Quevedo, Pilar ;
Sabate, Manel ;
Angiolillo, Dominick J. ;
Costa, Marco A. ;
Alfonso, Fernando ;
Gomez-Hospital, Joan Antoni ;
Hernandez-Antolin, Rosana ;
Banuelos, Camino ;
Goicolea, Javier ;
Fernandez-Aviles, Francisco ;
Bass, Theodore ;
Escaned, Javier ;
Moreno, Raul ;
Fernandez, Cristina ;
Macaya, Carlos .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (11) :2172-2179