Powerful Electron-Transfer Screen-Printed Platforms as Biosensing Tools: The Case of Uric Acid Biosensor

被引:16
作者
Cancelliere, Rocco [1 ]
Tinno, Alessio Di [1 ]
Cataldo, Antonino [2 ]
Bellucci, Stefano [2 ]
Micheli, Laura [1 ]
机构
[1] Univ Roma Tor Vergata, Dept Chem Sci & Technol, Via Ric Sci 1, I-00133 Rome, Italy
[2] INFN, Lab Nazl Frascati, Via E Fermi 54, I-00044 Frascati, Italy
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 01期
关键词
nanomaterials; screen-printed electrodes; uric acid; point-of-care device; ELECTROCHEMICAL BIOSENSORS; AMPEROMETRIC BIOSENSOR; GRAPHENE; PERFORMANCE; XANTHINE; SENSORS; SERUM; FIELD;
D O I
10.3390/bios12010002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of carbon nanomaterials (CNMs) in sensors and biosensor realization is one of the hottest topics today in analytical chemistry. In this work, a comparative in-depth study, exploiting different nanomaterial (MWNT-CO2H, -NH2, -OH and GNP) modified screen-printed electrodes (SPEs), is reported. In particular, the sensitivity, the heterogeneous electron transfer constant (k(0)), and the peak-to-peak separation (Delta E) have been calculated and analyzed. After which, an electrochemical amperometric sensor capable of determining uric acid (UA), based on the nano-modified platforms previously characterized, is presented. The disposable UA biosensor, fabricated modifying working electrode (WE) with Prussian Blue (PB), carbon nanotubes, and uricase enzyme, showed remarkable analytical performances toward UA with high sensitivity (CO2H 418 mu A mu M-1 cm(-2) and bare SPE-based biosensor, 33 mu A mu M-1 cm(-2)), low detection limits (CO2H 0.5 nM and bare SPE-based biosensors, 280 nM), and good repeatability (CO2H and bare SPE-based biosensors, 5% and 10%, respectively). Moreover, the reproducibility (RSD%) of these platforms in tests conducted for UA determination in buffer and urine samples results are equal to 6% and 15%, respectively. These results demonstrate that the nanoengineered electrode exhibited good selectivity and sensitivity toward UA even in the presence of interfering species, thus paving the way for its application in other bio-fluids such as simple point-of-care (POC) devices.
引用
收藏
页数:17
相关论文
共 58 条
[1]   A Review of Carbon Nanotubes Field Effect-Based Biosensors [J].
Alabsi, S. S. ;
Ahmed, Abdelaziz Yousif ;
Dennis, J. O. ;
Khir, M. H. Md ;
Algamili, A. S. .
IEEE ACCESS, 2020, 8 :69509-69521
[2]   How cutting-edge technologies impact the design of electrochemical (bio)sensors for environmental analysis. A review [J].
Arduini, Fabiana ;
Cinti, Stefano ;
Scognamiglio, Viviana ;
Moscone, Danila ;
Palleschi, Giuseppe .
ANALYTICA CHIMICA ACTA, 2017, 959 :15-42
[3]   Electrochemical biosensors based on nanomodified screen-printed electrodes: Recent applications in clinical analysis [J].
Arduini, Fabiana ;
Micheli, Laura ;
Moscone, Danila ;
Palleschi, Giuseppe ;
Piermarini, Silvia ;
Ricci, Francesco ;
Volpe, Giulia .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 79 :114-126
[4]   An amperometric biosensor for uric acid determination prepared from uricase immobilized in polyaniline-polypyrrole film [J].
Arslan, Fatma .
SENSORS, 2008, 8 (09) :5492-5500
[5]  
Brownson D.A.C., 2014, The Handbook of Graphene Electrochemistry, DOI [DOI 10.1007/978-1-4471-6428-9, 10.1007/978-1-4471-6428-9]
[6]   Electrochemical and morphological layer-by-layer characterization of electrode interfaces during a label-free impedimetric immunosensor build-up: The case of ochratoxin A [J].
Cancelliere, Rocco ;
Albano, David ;
Brugnoli, Benedetta ;
Buonasera, Katia ;
Leo, Gabriella ;
Margonelli, Andrea ;
Rea, Giuseppina .
APPLIED SURFACE SCIENCE, 2021, 567
[7]   An inverse-designed electrochemical platform for analytical applications [J].
Cancelliere, Rocco ;
Di Tinno, Alessio ;
Di Lellis, Andrea Maria ;
Tedeschi, Yannick ;
Bellucci, Stefano ;
Carbone, Katya ;
Signori, Emanuela ;
Contini, Giorgio ;
Micheli, Laura .
ELECTROCHEMISTRY COMMUNICATIONS, 2020, 121
[8]   Vegetable waste scaffolds for 3D-stem cell proliferating systems and low cost biosensors [J].
Cancelliere, Rocco ;
Zurlo, Francesca ;
Micheli, Laura ;
Melino, Sonia .
TALANTA, 2021, 223
[9]   Biochar from Brewers' Spent Grain: A Green and Low-Cost Smart Material to Modify Screen-Printed Electrodes [J].
Cancelliere, Rocco ;
Carbone, Katya ;
Pagano, Mauro ;
Cacciotti, Ilaria ;
Micheli, Laura .
BIOSENSORS-BASEL, 2019, 9 (04)
[10]   Uric acid biosensor based on chemiluminescence detection using a nano-micro hybrid matrix [J].
Chaudhari, Rashmi D. ;
Joshi, Abhijeet B. ;
Srivastava, Rohit .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 173 :882-889