Development and Validation of a Stability-Indicating HPTLC Assay Method for Idebenone

被引:2
作者
Rathi, A. A. [1 ]
Dhamecha, D. L. [1 ]
Dehghan, M. H. G. [1 ]
Saifee, M. [1 ]
Wakte, P. S. [2 ]
Shelke, S. D. [3 ]
Dongre, S. H. [3 ]
机构
[1] Maulana Azad Educ Trust, YB Chavan Coll Pharm, Dept Pharmaceut, Aurangabad 431001, Maharashtra, India
[2] Dr BAMU, Univ Dept Chem Technol, Aurangabad 431134, Maharashtra, India
[3] Yash Inst Pharm, Aurangabad 431134, Maharashtra, India
关键词
HPTLC; idebenone; stability-indicating assay; validation; stress testing;
D O I
10.1556/AChrom.23.2011.2.7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, selective, precise, and stability-indicating high-performance thin layer chromatographic (HPTLC) method has been established and validated for the analysis of idebenone in bulk drug and formulations. The compounds were analyzed on aluminum-backed silica gel 60 F-254 plates with petroleum ether-methanol (4:1, v/v) as mobile phase. Densitometric analysis of idebenone was performed at 282 nm. Regression analysis data for the calibration plots were indicative of good linear relationship between response and concentration over the range of 200-600 ng per spot. The correlation coefficient (r(2)) was 0.989 +/- 0.002. The values of slope and intercept of the calibration plots were 2.386 +/- 0.0435 and 577.733 +/- 19.545, respectively. The method was validated for precision, accuracy, robustness, and ruggedness. The limits of detection and quantification were 14.642 and 44.369 ng, respectively. Idebenone was subjected to acid, base, peroxide, and sunlight degradation. In stability tests, the drug was susceptible to acid and basic hydrolysis, oxidation, and photodegradation.
引用
收藏
页码:281 / 294
页数:14
相关论文
共 14 条
  • [1] [Anonymous], 2002, P INT CONV QUAL PHAR
  • [2] [Anonymous], METH INT C HARM GEN
  • [3] [Anonymous], INDIAN DRUGS
  • [4] [Anonymous], QUANTITATIVE ANAL PH
  • [5] [Anonymous], 2003, INT C HARMONIZATION
  • [6] [Anonymous], AJRC
  • [7] [Anonymous], ACTA CRYST
  • [8] [Anonymous], METH INT C HARM GEN
  • [9] Development of validated stability-indicating assay methods - critical review
    Bakshi, M
    Singh, S
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 28 (06) : 1011 - 1040
  • [10] Preparation and in vitro evaluation of self-microemulsifying drug delivery systems containing idebenone
    Kim, HJ
    Yoon, KA
    Hahn, M
    Park, ES
    Chi, SC
    [J]. DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2000, 26 (05) : 523 - 529