Determination of Functional Outcomes of Displaced Olecranon Fracture Fixed with Intermedullary Partially Threaded Screw Augmented with Tension Band Wiring

被引:0
作者
Makki, Muhammad Khizer Hayat [1 ]
Khan, Ghulam Qadir [2 ]
Saud, Abdul Munaf [3 ]
Mehmood, Shahid [4 ]
Ahmed, Zulfiqar [3 ]
Qureshi, Hafiz Muhammad Ahmad [5 ]
机构
[1] Bahawal Victoria Hosp, Civil Sadiq Abbasi Hosp, Bahawalpur, Pakistan
[2] QAMC, Bahawal Victoria Hosp, Bahawalpur, Pakistan
[3] Bahawal Victoria Hosp, Civil Sadiq Abbasi Hosp, Orthoped Surg, Bahawalpur, Pakistan
[4] Bahawal Victoria Hosp, Orthoped Surg, Bahawalpur, Pakistan
[5] Bahawal Victoria Hosp, Bahawalpur, Pakistan
来源
PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES | 2021年 / 15卷 / 09期
关键词
Olecranon fracture; Intramedullary partially threaded screw; Tension band wiring; Campbell's posterolateral approach; FIXATION;
D O I
10.53350/pjmhs211592594
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Orthopaedic injuries involving the olecranon are among the most often encountered in the emergency department. Objective: To determine the functional outcomes of displaced olecranon fracture fixed with intermedullary partially threaded screw augmented with tension band wiring Material and methods: This Descriptive/multicentric case series was conducted in Department of Orthopedics, Bahawal Victoria Hospital/Civil (Sadiq Abbasi) Hospital, Bahawalpur during June 2019 to June 2021. Patients who came through the emergency department and met the inclusion criteria were enrolled and given informed permission after clearance from the hospital's ethics committee. During general anesthesia or a biere's block, all patients received tension band wire and intramedullary screw fixation. Results: Functional outcomes of displaced olecranon fracture fixed with intermedullary partially threaded screw augmented with tension band wiring was recorded as excellent in 57.39%(n=66), 32.17%(n=37) had good outcome, 10.44%(n=12) had fair outcome. Conclusion: We concluded that that functional outcomes of displaced olecranon fracture fixed with intermedullary partially threaded screw augmented with tension band wiring is good; however, validation is required through other local studies.
引用
收藏
页码:2594 / 2596
页数:3
相关论文
共 12 条
[1]   Congruent Elbow Plate Fixation of Olecranon Fractures [J].
Anderson, Meredith L. ;
Larson, A. Noelle ;
Merten, Sheri M. ;
Steinmann, Scott P. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (06) :386-393
[2]  
Ashraf RA, 2018, PAK ARMED FORCES MED, V68, P1256
[4]   Long-term Outcome of Displaced, Transverse, Noncomminuted Olecranon Fractures [J].
Flinterman, Hendrik J. A. ;
Doornberg, Job N. ;
Guitton, Thierry G. ;
Ring, David ;
Goslings, J. Carel ;
Kloen, Peter .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (06) :1955-1961
[5]   Intramedullary compression device for proximal ulna fracture [J].
Hong, Choon Chiet ;
Han, Fucai ;
Decruz, Joshua ;
Pannirselvam, Vinodhkumar ;
Murphy, Diarmuid .
SINGAPORE MEDICAL JOURNAL, 2015, 56 (02) :E17-E20
[6]  
Kashif M, 2019, PROFESSIONAL MED J, V26, P1256
[7]   Olecranon fractures [J].
Newman, S. D. S. ;
Mauffrey, C. ;
Krikler, S. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2009, 40 (06) :575-581
[8]   Biomechanical comparison of bi- and tricortical k-wire fixation in tension band wiring osteosynthesis [J].
Nowotny, J. ;
Bischoff, F. ;
Ahlfeld, T. ;
Goronzy, J. ;
Tille, E. ;
Nimtschke, U. ;
Biewener, A. .
EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2019, 24 (01)
[9]   Cancellous Screw with Tension Band Wiring for Fractures of the Olecranon [J].
Raju, S. M. ;
Gaddagi, Rashmi A. .
JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2013, 7 (02) :339-341
[10]   Efficacy and safety of tension band wiring versus plate fixation in olecranon fractures: a systematic review and meta-analysis [J].
Ren, Yi-Ming ;
Qiao, Hu-Yun ;
Wei, Zhi-Jian ;
Lin, Wei ;
Fan, Bao-You ;
Liu, Jun ;
Li, Ang ;
Kang, Yi ;
Liu, Shen ;
Hao, Yan ;
Zhou, Xian-Hu ;
Feng, Shi-Qing .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2016, 11