A sub-minute CZE method to determine nitrate and nitrite in meat products: An alternative for routine analysis

被引:24
作者
Della Betta, Fabiana [1 ]
Pereira, Lais Morilla [1 ]
Siqueira, Mariana Araujo [1 ]
Valese, Andressa Camargo [1 ,2 ]
Daguer, Heitor [2 ]
Fett, Roseane [1 ]
Vitali, Luciano [3 ]
Oliveira Costa, Ana Carolina [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Food Sci & Technol, BR-88034001 Florianopolis, SC, Brazil
[2] Minist Agr Livestock & Supply, Nacl Agr Lab, BR-88102600 Sao Jose, SC, Brazil
[3] Univ Fed Santa Catarina, Dept Chem, BR-88040900 Florianopolis, SC, Brazil
关键词
Sub-minute method; Routine analysis; Meat products; Analytical validation; Uncertainty measurement; CAPILLARY-ELECTROPHORESIS; CURED MEAT; VALIDATION; VEGETABLES; SAMPLES; EXTRACTION;
D O I
10.1016/j.meatsci.2016.04.011
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A sub-minute capillary zone electrophoresis (CZE) method was optimized and a simple sample preparation procedure based on the extraction of the analytes with water and sodium tetraborate was developed for the simultaneous determination of nitrate and nitrite levels in meat products. The background electrolyte (BGE) was composed of 20 mmol L-1 perchloric acid and 65 mmol L-1 beta-alanine at pH 3.83. Thiocyanate was used as the internal standard. The proposed method was validated and the uncertainty estimated according to Eurachem guidelines. The run time was only 30 s, allowing analyzing more than 25 samples/h, the good analytical performance confirms the suitability of the method for the analysis of meat products. One sample presented residual nitrite levels above the limit established by MERCOSUL legislation (150 mg kg(-1)). The use of a fast method in association with a simple sample preparation step means that this procedure represents a possible alternative to fulfill the demand for high throughput in routine laboratory analysis. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:62 / 68
页数:7
相关论文
共 38 条
[1]   A flow-injection spectrophotometric method for nitrate and nitrite,determination through nitric oxide generation [J].
Andrade, R ;
Viana, CO ;
Guadagnin, SG ;
Reyes, FGR ;
Rath, S .
FOOD CHEMISTRY, 2003, 80 (04) :597-602
[2]  
[Anonymous], 1983, Statistical Methods
[3]  
[Anonymous], 1998, FITN PURP AN METH LA
[4]  
[Anonymous], 1975, 2918 ISO
[5]  
AOAC, 2005, 97331 AOAC
[6]  
Brasil, 2009, 152009GABDIPOA
[7]  
Brasil, 2006, REG TECN ATR AD SEUS
[8]   Practical method validation: Validation sufficient for an analysis method [J].
Bruce, P ;
Minkkinen, P ;
Riekkola, ML .
MIKROCHIMICA ACTA, 1998, 128 (1-2) :93-106
[9]   Nitrite and nitrosyl compounds in food preservation [J].
Cammack, R ;
Joannou, CL ;
Cui, XY ;
Martinez, CT ;
Maraj, SR ;
Hughes, MN .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOENERGETICS, 1999, 1411 (2-3) :475-488
[10]   Flow injection analysis of nitrate-N determination in root vegetables: Study of the effects of cooking [J].
Chetty, Adrian Avinesh ;
Prasad, Surendra .
FOOD CHEMISTRY, 2009, 116 (02) :561-566