Epicardial isolation of pulmonary veins with ethanol in open chest dogs

被引:0
作者
Yin Xian-dong [1 ]
Ning Man [1 ]
Sang Cai-hua [1 ]
Miao Cheng-long [1 ]
Liang Cui [1 ]
Tang Ri-bo [1 ]
Long De-yong [1 ]
Yu Rong-hui [1 ]
Liu Xing-peng [1 ]
Dong Jian-zeng [1 ]
Ma Chang-sheng [1 ]
机构
[1] Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiol, Beijing 100029, Peoples R China
基金
中国国家自然科学基金;
关键词
ethanol; pulmonary vein isolation; epicardial; atrial fibrillation; RADIOFREQUENCY CATHETER ABLATION; ATRIAL-FIBRILLATION; ELECTRICAL DISCONNECTION; TISSUE; TACHYCARDIA; CONDUCTION; PATHWAYS; INFUSION; INJURY;
D O I
10.3760/cma.j.issn.0366-6999.2011.11.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Radiofrequency (RF) ablation has become a widely accepted treatment for atrial fibrillation (AF). This study aimed to identify the efficacy and safety of pulmonary vein (PV) ablation with ethanol and to explore an alternative energy source for catheter ablation of AF. Methods Twelve open-chest mongrel dogs were randomized into ethanol ablation group and control group. Both the injections and electrophysiological mapping procedures were performed epicardialy. In ethanol ablation group (n=6), injections were performed to circumferentially ablate the root of each PV (0.2 ml each site, 3 mm apart) with 95% ethanol using an 1 ml injector. In control group (n=6), saline was injected other than ethanol. PV isolation was confirmed with a circular catheter immediately after the procedure and at follow up of 30 days. PV isolation was defined as the absence of PV potentials at each electrode of the circular catheter positioned at the PV side of the lesions, as well as complete conduction block into left atrium (LA) during PV pacing. Results PV electrical isolation with complete bidirectional conduction block was achieved with ethanol immediately and at 30 days in 95% of PVs, while saline injection caused only transient conduction changes between LA and PVs. In ethanol group, histologic analysis showed transmural lesions at 30 days. And there was no evidence of PV stenosis or thrombus formation. Mean LA diameter was not significantly different between baseline and 30 days. Conclusion Ethanol is a safe energy source to effectively isolate PV in canine model and may be promising in endocardial ablation procedure of AF patients in the future. Chin Med J 2011;124(11):1714-1719
引用
收藏
页码:1714 / 1719
页数:6
相关论文
共 50 条
  • [41] Comparison of ThermoCool® Surround Flow Catheter Versus ThermoCool® Catheter in Achieving Persistent Electrical Isolation of Pulmonary Veins: A Pilot Study
    Bertaglia, Emanuele
    Fassini, Gaetano
    Anselmino, Matteo
    Stabile, Giuseppe
    Grandinetti, Giuseppe
    De Simone, Antonio
    Calo, Leonardo
    Pandozi, Claudio
    Pratola, Claudio
    Zoppo, Franco
    Tondo, Claudio
    Iuliano, Assunta
    Gaita, Fiorenzo
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (03) : 269 - 273
  • [42] Standardized pulmonary vein isolation workflow to enclose veins with contiguous lesions: the multicentre VISTAX trial
    Duytschaever, Mattias
    Vijgen, Johan
    De Potter, Tom
    Scherr, Daniel
    Van Herendael, Hugo
    Knecht, Sebastien
    Kobza, Richard
    Berte, Benjamin
    Sandgaard, Niels
    Albenque, Jean-Paul
    Szeplaki, Gabor
    Stevenhagen, Yorick Jeroen
    Taghji, Philippe
    Wright, Matthew
    Macours, Nathalie
    Gupta, Dhiraj
    EUROPACE, 2020, 22 (11): : 1645 - 1652
  • [43] Initial Experience With Robotic Epicardial Off-Pump Pulmonary Vein Isolation for Paroxysmal Atrial Fibrillation
    Casselman, Filip
    Bakir, Ihsan
    Brugada, Pedro
    Geelen, Peter
    Wellens, Francis
    Van Praet, Frank
    Gegrieck, Ivan
    Vermeulen, Yvette
    Vanermen, Hugo
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2006, 1 (05) : 247 - 250
  • [44] Percutaneous Recanalization of Totally Occluded Pulmonary Veins After Pulmonary Vein Isolation-Intermediate-Term Follow-Up
    Hill, James
    Qureshi, Athar M.
    Worley, Sarah
    Prieto, Lourdes R.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (04) : 585 - 591
  • [45] Antazoline for termination of atrial fibrillation during the procedure of pulmonary veins isolation
    Balsam, Pawel
    Kozluk, Edward
    Peller, Michal
    Piatkowska, Agnieszka
    Lodzinski, Piotr
    Kiliszek, Marek
    Koltowski, Lukasz
    Grabowski, Marcin
    Opolski, Grzegorz
    ADVANCES IN MEDICAL SCIENCES, 2015, 60 (02): : 231 - 235
  • [46] Reliability of luminal oesophageal temperature monitoring during pulmonary veins isolation
    Fasano, Antonio
    EUROPACE, 2017, 19 (08): : 1411 - 1411
  • [47] Usefulness of transesophageal echocardiography in the isolation of pulmonary veins in the treatment of atrial fibrillation
    Champagne, Jean
    Echahidi, Najmeddine
    Philippon, Francois
    St-Pierre, Andre
    Molin, Franck
    Blier, Louis
    Gilbert, Marcel
    Villeneuve, Jacques
    Mohty, Dania
    O'Hara, Gilles
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 : S116 - S119
  • [48] Isolation of pulmonary veins using a thermoreactive implantable device with external energy transfer: Evaluation in a porcine model
    Boussy, Tim
    Vandecasteele, Tim
    Vera, Lisse
    Schauvliege, Stijn
    Philpott, Matthew
    Clement, Eli
    van Loon, Gunther
    Willenz, Udi
    Granada, Juan F.
    Stone, Gregg W.
    Reddy, Vivek Y.
    Van Langenhove, Glenn
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (06): : 603 - 610
  • [49] The Minimum Number of Ablation Lines for Complete Isolation of the Pulmonary Veins during Thoracoscopic Ablation for Atrial Fibrillation
    Choi, Min Suk
    Lee, Yoonseo
    Jeong, Dong Seop
    LIFE-BASEL, 2023, 13 (03):
  • [50] ATP-Induced Dormant Pulmonary Veins Originating from the Carina Region After Circumferential Pulmonary Vein Isolation of Atrial Fibrillation
    Kumagai, Koji
    Naito, Shigeto
    Nakamura, Koki
    Hayashi, Tatsuya
    Fukazawa, Rie
    Sato, Chizuru
    Takemura, Naoki
    Miki, Yuko
    Fuke, Etsuko
    Tanaka, Yasuaki
    Hori, Yasuhiko
    Goto, Koji
    Iwamoto, Jotaro
    Aonuma, Kazutaka
    Oshima, Shigeru
    Taniguchi, Koichi
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (05) : 494 - 500