摘要
Purpose: To determine if ocular pulse amplitude (OPA) as measured by dynamic contour tonometry (DCT) is related to severity of glaucoma, and if intraocular pressure (IOP) as measured by DCT is related to central corneal thickness (CCT). Methods: Patients were selected from the Duke Eye Center glaucoma clinic. Fifty-five eyes of 32 patients were included; right and left eyes were analyzed separately. CCT, OPA, DCT IOP, Goldmann applanation tonometry (GAT), Tonopen applanation tonometry (TAT), and systemic blood pressure were measured. Advanced Glaucoma Intervention Study score and mean deviation of visual field, and vertical and horizontal cup-disc ratios were recorded in a masked manner. Descriptive statistics were obtained, and OPA, DCT IOP, GAT, and TAT underwent univariate analyses to assess for relationships with predictor variables. Results: OPA, DCT IOP, GAT, and TAT were positively associated with CCT and with having no surgical intervention for right and left eyes, and were negatively associated with vertical and horizontal cup-disc ratios. Conclusions: Increased OPA seems to correlate with less severe glaucoma and with increased CCT. DCT IOP seems to be affected by CCT along with GAT and TAT.
引用
收藏
页码:700 / 703
页数:4
相关论文
共 35 条
[1]  
Agarwal Harish C., 2003, Indian Journal of Ophthalmology, V51, P133
[2]   Effect of a nifedipine induced reduction in blood pressure on the association between ocular pulse amplitude and ocular fundus pulsation amplitude in systemic hypertension [J].
Bayerle-Eder, M ;
Kolodjaschna, J ;
Wolzt, M ;
Polska, E ;
Gasic, S ;
Schmetterer, L .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (06) :704-708
[3]   Repeatability of ocular blood flow pneumotonometry [J].
Bhan, A ;
Bhargava, J ;
Vernon, SA ;
Armstrong, S ;
Bhan, K ;
Tong, L ;
Sung, V .
OPHTHALMOLOGY, 2003, 110 (08) :1551-1554
[4]  
Bhan A, 2002, INVEST OPHTH VIS SCI, V43, P1389
[5]  
Claridge K G, 1994, Surv Ophthalmol, V38 Suppl, pS198, DOI 10.1016/0039-6257(94)90067-1
[6]   Comparison of dynamic contour tonometry with Goldman applanation tonometry over a wide range of central corneal thickness [J].
Doyle, A ;
Lachkar, Y .
JOURNAL OF GLAUCOMA, 2005, 14 (04) :288-292
[7]   The effect of systemic hypertension on pulsatile ocular blood flow in diabetic patients [J].
Esgin, H ;
Alimgil, ML ;
Erda, S .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2001, 79 (02) :160-162
[8]  
GAASTERLAND DE, 1994, OPHTHALMOLOGY, V101, P1445
[9]   The short-term effect of latanoprost on intraocular pressure and pulsatile ocular blood flow [J].
Georgopoulos, GT ;
Diestelhorst, M ;
Fisher, R ;
Ruokonen, P ;
Krieglstein, GK .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2002, 80 (01) :54-58
[10]   Pulsatile ocular blood flow in diabetic retinopathy [J].
Geyer, O ;
Neudorfer, M ;
Snir, T ;
Goldstein, M ;
Rock, T ;
Silver, DM ;
Bartov, E .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 1999, 77 (05) :522-525