Evaluation of dentinal defect formation after root canal preparation with two reciprocating systems and hand instruments: an in vitro study

被引:14
作者
Helvacioglu-Yigit, Dilek [1 ]
Aydemir, Seda [1 ]
Yilmaz, Ayca [2 ]
机构
[1] Kocaeli Univ, Fac Dent, Dept Endodont, Kocaeli, Turkey
[2] Istanbul Univ, Fac Dent, Dept Endodont, Istanbul, Turkey
关键词
vertical root fracture; reciprocating instruments; root canal preparations; CYCLIC FATIGUE; FRACTURE SUSCEPTIBILITY; ROTARY INSTRUMENTATION; GATES-GLIDDEN; WAVEONE; THICKNESS; DIAGNOSIS; PATTERN; DRILLS; FILES;
D O I
10.1080/13102818.2014.996982
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The purpose of this study was to evaluate the presence of dentinal defects after root canal preparation with hand instruments and two different reciprocating instruments. Sixty freshly extracted mandibular incisor teeth were selected for this in vitro study. On the basis of root length, mesiodistal and buccolingual dimensions, the teeth were allocated into three identical experimental groups (n = 15) and one control group (n = 15). The teeth in the control group were left unprepared. The other groups were: stainless steel hand instruments, WaveOne (R) Primary instruments and RECIPROC (R) R25 instruments. The reciprocating instruments were used with a reciprocating gentle in-and-out motion in a torque-limited electric motor at the appropriate preset mode. Horizontal sections were made 3, 6 and 9 mm from the apex. Samples were stained with methylene blue and viewed through a stereomicroscope. The presence of dentinal defects (fractures, incomplete cracks and craze lines) and their locations were investigated by two endodontists. These data were analysed statistically by Fisher's exact and chi-square tests. No defects were observed in the unprepared group. All instruments caused dentinal defects, with no significant differences between the instrument systems. All experimental groups demonstrated significantly more defects at the 3-mm level in comparison with the unprepared group (p = 0.032). At the other levels, there was no significant difference between the experimental groups and the control group. The use of hand or reciprocating instruments could induce the formation of dentinal defects during root canal preparation.
引用
收藏
页码:368 / 373
页数:6
相关论文
共 33 条
[1]   The effect of working length and root canal preparation technique on crack development in the apical root canal wall [J].
Adorno, C. G. ;
Yoshioka, T. ;
Suda, H. .
INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (04) :321-327
[2]   Comparison of the shaping abilities of three nickel-titanium instrumentation systems using micro-computed tomography [J].
Baek, Jin Yi ;
Yoo, Hyun Mi ;
Park, Dong Sung ;
Oh, Tae Seok ;
Kum, Kee Yeon ;
Shin, Seung Yun ;
Chang, Seok Woo .
JOURNAL OF DENTAL SCIENCES, 2014, 9 (02) :111-117
[3]   Vertical Root Fractures and Dentin Defects: Effects of Root Canal Preparation, Filling, and Mechanical Cycling [J].
Barreto, Mirela Sangoi ;
Moraes, Rafael do Amaral ;
da Rosa, Ricardo Abreu ;
Cunha Moreira, Carlos Heitor ;
Reis So, Marcus Vinicius ;
Souza Bier, Carlos Alexandre .
JOURNAL OF ENDODONTICS, 2012, 38 (08) :1135-1139
[4]  
Bergmans L, 2001, AM J DENT, V14, P324
[5]   Canal Shaping with WaveOne Primary Reciprocating Files and ProTaper System: A Comparative Study [J].
Berutti, Elio ;
Chiandussi, Giorgio ;
Paolino, Davide Salvatore ;
Scotti, Nicola ;
Cantatore, Giuseppe ;
Castellucci, Arnaldo ;
Pasqualini, Damiano .
JOURNAL OF ENDODONTICS, 2012, 38 (04) :505-509
[6]   Incidence of Dentinal Defects after Root Canal Preparation: Reciprocating versus Rotary Instrumentation [J].
Buerklein, Sebastian ;
Tsotsis, Polymnia ;
Schaefer, Edgar .
JOURNAL OF ENDODONTICS, 2013, 39 (04) :501-504
[7]   Vertical root fractures - Clinical and radiographic diagnosis [J].
Cohen, S ;
Blanco, L ;
Berman, L .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2003, 134 (04) :434-441
[8]   Effects of Self-Adjusting File, Mtwo, and Pro Taper on the Root Canal Wall [J].
Hin, Ellemieke S. ;
Wu, Min-Kai ;
Wesselink, Paul R. ;
Shemesh, Hagay .
JOURNAL OF ENDODONTICS, 2013, 39 (02) :262-264
[9]   Comparison between a Novel Nickel-Titanium Alloy and 508 Nitinol on the Cyclic Fatigue Life of ProFile 25/.04 Rotary Instruments [J].
Johnson, Eugenia ;
Lloyd, Adain ;
Kuttler, Sergio ;
Namerow, Kenneth .
JOURNAL OF ENDODONTICS, 2008, 34 (11) :1406-1409
[10]   Cyclic Fatigue and Torsional Resistance of Two New Nickel-Titanium Instruments Used in Reciprocation Motion: Reciproc Versus WaveOne [J].
Kim, Hyeon-Cheol ;
Kwak, Sang-Won ;
Cheung, Gary Shun-Pan ;
Ko, Dae-Hoon ;
Chung, Se-Min ;
Lee, WooCheol .
JOURNAL OF ENDODONTICS, 2012, 38 (04) :541-544