Permanent gold nanoparticle coatings on polyelectrolyte multilayer modified capillaries for open-tubular capillary electrochromatography

被引:46
作者
Qu, Qishu [1 ]
Liu, Dengping [1 ]
Mangelings, Debby [2 ]
Yang, Chun [1 ]
Hu, Xiaoya [1 ]
机构
[1] Yangzhou Univ, Coll Chem & Chem Engn, Jiangsu Key Lab Environm Mat & Environm Engn, Yangzhou 225002, Jiangsu, Peoples R China
[2] Vrije Univ Brussel, Pharmaceut Res Ctr, Dept Analyt Chem & Pharmaceut Technol, B-1090 Brussels, Belgium
基金
中国国家自然科学基金;
关键词
Polyelectrolyte multilayer coating; Open-tubular capillary electrochromatography; Gold nanoparticles; TITANIUM-DIOXIDE NANOPARTICLES; IONIC POLYMER LAYERS; ELECTROOSMOTIC FLOW; PROTEIN SEPARATIONS; MOLECULAR MICELLES; ELECTROPHORESIS; COLUMN; FILMS; PHASE; NANOTECHNOLOGY;
D O I
10.1016/j.chroma.2010.08.057
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper reports on a new strategy to coat fused silica capillaries through ionic adsorption of gold nanoparticles (AuNPs) on a polyelectrolyte multilayer (PEM) modified capillary wall. The coating was constructed in situ by alternating rinses with positively charged poly(diallydimethylammonium chloride), negatively charged poly(sodium-4-styrenesulfonate), and positively charged AuNPs. After self-assembly of n-octadecanethiol onto the surface of AuNPs, the modified capillary was investigated as a new medium for the separation of neutral analytes and proteins in open-tubular capillary electrochromatography (OT-CEC). The surface coverage of the capillary wall was increased using the high density of AuNPs which were dynamically capped with 4-dimethylaminopyridine (DMAP). The chromatographic performance of the column coated with positively charged AuNPs was remarkably improved compared with a column modified with negatively charged AuNPs. The coating was robust over more than 810 runs in this study and also showed high stability against 0.01 M NaOH, 0.01 M HCl, and electrolyte concentrations up to 70 mM. The run-to-run, day-to-day, and capillary-to-capillary reproducibilities of electroosmotic flow were satisfying with relative standard deviation values of less than 1% in all cases. The AuNP-coated PEM modified capillary column not only showed good performance for neutral analytes but also was suitable for the analysis of both basic and acidic proteins. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:6588 / 6594
页数:7
相关论文
共 51 条
[1]   Plastic microfluidic devices modified with polyelectrolyte multilayers [J].
Barker, SLR ;
Tarlov, MJ ;
Canavan, H ;
Hickman, JJ ;
Locascio, LE .
ANALYTICAL CHEMISTRY, 2000, 72 (20) :4899-4903
[2]  
Bendahl L, 2001, ELECTROPHORESIS, V22, P2565, DOI 10.1002/1522-2683(200107)22:12<2565::AID-ELPS2565>3.0.CO
[3]  
2-I
[4]  
Boyce MC, 2000, ELECTROPHORESIS, V21, P3073, DOI 10.1002/1522-2683(20000901)21:15<3073::AID-ELPS3073>3.0.CO
[5]  
2-H
[6]   Influence of mobile phase composition on electroosmotic flow velocity, solute retention and column efficiency in open-tubular reversed-phase capillary electrochromatography [J].
Crego, AL ;
Martínez, J ;
Marina, ML .
JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) :329-337
[7]   Control of the EOF in CE using polyelectrolytes of different charge densities [J].
Danger, Gregoire ;
Ramonda, Michel ;
Cottet, Herve .
ELECTROPHORESIS, 2007, 28 (06) :925-931
[8]   Gold nanoparticles: Assembly, supramolecular chemistry, quantum-size-related properties, and applications toward biology, catalysis, and nanotechnology [J].
Daniel, MC ;
Astruc, D .
CHEMICAL REVIEWS, 2004, 104 (01) :293-346
[9]   Fuzzy nanoassemblies: Toward layered polymeric multicomposites [J].
Decher, G .
SCIENCE, 1997, 277 (5330) :1232-1237
[10]  
Decher G, 1992, THIN SOLID FILMS, V2, P210