Tandem dye acceptor used to enhance upconversion fluorescence resonance energy transfer in homogeneous assays

被引:42
|
作者
Rantanen, Terhi [1 ]
Pakkila, Henna [1 ]
Jamsen, Laura [1 ]
Kuningas, Katri [1 ]
Ukonaho, Telle [1 ]
Lovgren, Tirno [1 ]
Soukka, Tero [1 ]
机构
[1] Univ Turku, Dept Biotechnol, FIN-20520 Turku, Finland
关键词
D O I
10.1021/ac070376w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In fluorescence resonance energy transfer (FRET)-based assays, spectral separation of acceptor emission from donor emission is a common problem affecting the assay sensitivity. The challenge derives from small Stokes shifts characteristic to conventional fluorescent dyes resulting in leakage of donor emission to the measurement window intended only to collect the acceptor emission. We have studied a FRET-based homogeneous bioaffinity assay utilizing a tandem dye acceptor with a large pseudo-Stokes shift (139 nm). The tandem dye was constructed using B-phycoerythrin as an absorber and multiple Alexa Fluor 680 dyes as emitters. As a donor, we employed upconverting phosphor particles, which uniquely emit at visible wavelengths under low-energy infrared excitation enabling the fluorescence measurements free from autofluorescence even without time-resolved detection. With the tandem dye, it was possible to achieve four times higher signal from a single binding event compared to the conventional Alexa Fluor 680 dye alone. Tandem dyes are widely used in cytometry and other multiplex purposes, but their applications can be expanded to fluorescence-based homogeneous assays. Both the optimal excitation and emission wavelengths of tandem dye can be tuned to a desired region by choosing appropriate fluorophores enabling specifically designed acceptor dyes with large Stokes shift.
引用
收藏
页码:6312 / 6318
页数:7
相关论文
共 50 条
  • [42] Photochromism-FRET (phFRET): Modulation of fluorescence resonance energy transfer by a photochromic acceptor
    JaresErijman, EA
    Song, LL
    Jovin, TM
    MOLECULAR CRYSTALS AND LIQUID CRYSTALS SCIENCE AND TECHNOLOGY SECTION A-MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 1997, 297 : 427 - 435
  • [43] Fluorescence resonance energy transfer (FRET) using ssDNA binding fluorescent dye
    Orpana, KA
    BIOMOLECULAR ENGINEERING, 2004, 21 (02): : 45 - 50
  • [44] An upconversion fluorescence resonance energy transfer nanosensor for one step detection of melamine in raw milk
    Wu, Qiongqiong
    Long, Qian
    Li, Haitao
    Zhang, Youyu
    Yao, Shouzhuo
    TALANTA, 2015, 136 : 47 - 53
  • [45] An upconversion nanocomposite for fluorescence resonance energy transfer based cholesterol-sensing in human serum
    Ding, Yujie
    Zhu, Hao
    Zhang, Xiaoxia
    Gao, Jiangang
    Abdel-Halim, E. S.
    Jiang, Liping
    Zhu, Jun-Jie
    NANOSCALE, 2014, 6 (24) : 14792 - 14798
  • [46] DETERMINATION OF SALMONELLA TYPHIMURIUM BY A FLUORESCENCE RESONANCE ENERGY TRANSFER BIOSENSOR USING UPCONVERSION NANOPARTICLES AS LABELS
    Ma, Xiaoyuan
    Li, Shuang
    Xia, Yu
    Wang, Zhouping
    ANALYTICAL LETTERS, 2014, 47 (12) : 2048 - 2060
  • [47] Excitonic heterodimer formation in an HIV-1 oligonucleotide labeled with a donor-acceptor pair used for fluorescence resonance energy transfer
    Bernacchi, S
    Piémont, E
    Potier, N
    van Dorsselaer, A
    Mély, Y
    BIOPHYSICAL JOURNAL, 2003, 84 (01) : 643 - 654
  • [48] Can Nanocavities Significantly Enhance Resonance Energy Transfer in a Single Donor-Acceptor Pair?
    Wei, Yu-Chen
    Lee, Ming-Wei
    Chou, Pi-Tai
    Scholes, Gregory D.
    Schatz, George C.
    Hsu, Liang-Yan
    JOURNAL OF PHYSICAL CHEMISTRY C, 2021, 125 (33): : 18119 - 18128
  • [49] Homogeneous Immunosensor Based on Luminescence Resonance Energy Transfer for Glycated Hemoglobin Detection Using Upconversion Nanoparticles
    Jo, Eun-Jung
    Mun, Hyoyoung
    Kim, Min-Gon
    ANALYTICAL CHEMISTRY, 2016, 88 (05) : 2742 - 2746
  • [50] Homogeneous immunoassay based on two-photon excitation fluorescence resonance energy transfer
    Liu, Lingzhi
    Shao, Mei
    Dong, Xiaohu
    Yu, Xuefeng
    Liu, Zhihong
    He, Zhike
    Wang, Ququan
    ANALYTICAL CHEMISTRY, 2008, 80 (20) : 7735 - 7741