Solid phase extraction of trace Hg(II) on silica gel modified with 2-(2-oxoethyl)hydrazine carbothioamide and determination by ICP-AES

被引:112
|
作者
Chai, Xiaoli [1 ]
Chang, Xijun [1 ]
Hu, Zheng [1 ]
He, Qun [1 ]
Tu, Zhifeng [1 ]
Li, Zhenhua [1 ]
机构
[1] Lanzhou Univ, Dept Chem, Lanzhou 730000, Gansu, Peoples R China
关键词
Silica gel; 2-(2-Oxoethyl)hydrazine carbothioamide; Solid phase extraction; Hg(II); Inductively coupled plasma atomic emission spectrometry (ICP-AES); ATOMIC-ABSORPTION-SPECTROMETRY; OPTICAL-EMISSION-SPECTROMETRY; ENVIRONMENTAL WATER SAMPLES; SELECTIVE SEPARATION; SPECTROPHOTOMETRIC DETERMINATION; PRECONCENTRATION; MERCURY; ION; METALS; RESIN;
D O I
10.1016/j.talanta.2010.07.076
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a new 2-(2-oxoethyl)hydrazine carbothioamide modified silica gel (SG-OHC) sorbent was prepared and applied for preconcentration of trace mercury(II) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). The optimization of some analytical parameters affecting the adsorption of the analyte such as acidity, shaking time, sample now rate and volume, eluent condition, and interfering substances were investigated. At pH 3, the maximum static adsorption capacity of Hg(II) onto the SG-OHC was 37.5 mg g(-1). The quantitative recovery (>95%) of Hg(II) could be obtained using 2 mL of 0.5 mol L-1 HCl and 1% CS(NH2)(2) solution as eluent. Common coexisting substances did not interfere with the separation of mercury(II) under optimal conditions. The detection limit of present method was 0.10 ng mL(-1), and the relative standard deviation (RSD) was lower than 4.0% (n = 8). The prepared sorbent was successfully applied for the preconcentration of trace Hg(II) in certified and water samples with satisfactory results. (C) 2010 Elsevier BM. All rights reserved.
引用
收藏
页码:1791 / 1796
页数:6
相关论文
共 50 条
  • [21] Solid-phase extraction and preconcentration of trace Pb(II) from water samples with folic acid modified silica gel
    Wang, Qihui
    Chang, Xijun
    Hu, Zheng
    Li, Dandan
    Tu, Zhifeng
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2012, 92 (11) : 1251 - 1263
  • [22] Enrichment of trace Hg(II) ions from food and water samples after solid phase extraction combined with ICP-OES determination
    Ahmad, Hilal
    Koo, Bon Heun
    Khan, Rais Ahmad
    MICROCHEMICAL JOURNAL, 2022, 175
  • [23] Preconcentration, separation and determination of trace Hg(II) in environmental samples with aminopropylbenzoylazo-2-mercaptobenzothiazole bonded to silica gel
    Ma, WX
    Liu, F
    Li, KA
    Chen, M
    Tong, SY
    ANALYTICA CHIMICA ACTA, 2000, 416 (02) : 191 - 196
  • [24] ICP-AES determination of trace elements after preconcentrated with p-dimethylaminobenzaldehyde-modified nanometer SiO2 from sample solution
    Cui, Yuemei
    Chang, Xijun
    Zhai, Yiinhui
    Zhu, Xiangbing
    Zheng, Hong
    Lian, Ning
    MICROCHEMICAL JOURNAL, 2006, 83 (01) : 35 - 41
  • [25] Determination of Trace Copper in Drinking Water by Flame Atomic Absorption Spectrometry After Solid Phase Extraction on Polymer Modified Silica Gel
    Chen, Jing
    Wang, Ning
    Li, Bo
    Wan, Dongjin
    Sun, Xuzhuo
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (16) : 9041 - 9044
  • [26] Preconcentration and determination of Cu(II) in a fresh water sample using modified silica gel as a solid-phase extraction adsorbent
    Pereira, A. S.
    Ferreira, G.
    Caetano, L.
    Martines, M. A. U.
    Padilha, P. M.
    Santos, A.
    Castro, G. R.
    JOURNAL OF HAZARDOUS MATERIALS, 2010, 175 (1-3) : 399 - 403
  • [27] Selective solid phase extraction of trace cadmium(II) and lead(II) from biological and natural water samples by ofloxacin-modified-silica gel
    Cui, Yuemei
    Chang, Xijun
    Zhu, Xiangbing
    Zou, Xiaojun
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2008, 88 (12) : 857 - 868
  • [28] Determination of aluminum fractionation in soil extracts by using Eriochrome Cyanine R modified anion-exchange resin as solid phase extraction cartridge coupled with ICP-AES
    Luo, Ming-Biao
    Wu, Hong
    Zhang, Jing
    Shen, Dongxu
    Bi, Shu-Ping
    SEPARATION SCIENCE AND TECHNOLOGY, 2008, 43 (08) : 2225 - 2241
  • [29] Spectrophotometric Determination of Iron(II) after Solid Phase Extraction of Its 2,2′ Bipyridine Complex on Silica Gel-Polyethylene Glycol
    Pourreza, Nahid
    Rastegarzadeh, Saadat
    Kiasat, Ali Reza
    Yahyavi, Hossein
    JOURNAL OF SPECTROSCOPY, 2013, 2013
  • [30] Selective Solid-phase Extraction of Cu2+ by a Novel Cu(II)-imprinted Silica Gel
    Faghihian, Hossein
    Asghari, Khadijeh
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2013, 60 (12) : 1491 - 1499