Solid phase extraction of trace Hg(II) on silica gel modified with 2-(2-oxoethyl)hydrazine carbothioamide and determination by ICP-AES

被引:113
作者
Chai, Xiaoli [1 ]
Chang, Xijun [1 ]
Hu, Zheng [1 ]
He, Qun [1 ]
Tu, Zhifeng [1 ]
Li, Zhenhua [1 ]
机构
[1] Lanzhou Univ, Dept Chem, Lanzhou 730000, Gansu, Peoples R China
关键词
Silica gel; 2-(2-Oxoethyl)hydrazine carbothioamide; Solid phase extraction; Hg(II); Inductively coupled plasma atomic emission spectrometry (ICP-AES); ATOMIC-ABSORPTION-SPECTROMETRY; OPTICAL-EMISSION-SPECTROMETRY; ENVIRONMENTAL WATER SAMPLES; SELECTIVE SEPARATION; SPECTROPHOTOMETRIC DETERMINATION; PRECONCENTRATION; MERCURY; ION; METALS; RESIN;
D O I
10.1016/j.talanta.2010.07.076
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a new 2-(2-oxoethyl)hydrazine carbothioamide modified silica gel (SG-OHC) sorbent was prepared and applied for preconcentration of trace mercury(II) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). The optimization of some analytical parameters affecting the adsorption of the analyte such as acidity, shaking time, sample now rate and volume, eluent condition, and interfering substances were investigated. At pH 3, the maximum static adsorption capacity of Hg(II) onto the SG-OHC was 37.5 mg g(-1). The quantitative recovery (>95%) of Hg(II) could be obtained using 2 mL of 0.5 mol L-1 HCl and 1% CS(NH2)(2) solution as eluent. Common coexisting substances did not interfere with the separation of mercury(II) under optimal conditions. The detection limit of present method was 0.10 ng mL(-1), and the relative standard deviation (RSD) was lower than 4.0% (n = 8). The prepared sorbent was successfully applied for the preconcentration of trace Hg(II) in certified and water samples with satisfactory results. (C) 2010 Elsevier BM. All rights reserved.
引用
收藏
页码:1791 / 1796
页数:6
相关论文
共 35 条
[1]   Alumina physically loaded by thiosemicarbazide for selective preconcentration of mercury(II) ion from natural water samples [J].
Ahmed, Salwa A. .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 156 (1-3) :521-529
[2]   Selective separation of mercury(II) using a synthetic resin containing amine and mercaptan as chelating groups [J].
Atia, AA ;
Donia, AM ;
Elwakeel, KZ .
REACTIVE & FUNCTIONAL POLYMERS, 2005, 65 (03) :267-275
[3]   Sorption and filtration of Hg(II) ions from aqueous solutions with a membrane containing poly(ethyleneimine) as a complexing polymer [J].
Bessbousse, H. ;
Rhlalou, T. ;
Verchere, J. -F. ;
Lebrun, L. .
JOURNAL OF MEMBRANE SCIENCE, 2008, 325 (02) :997-1006
[4]   Uses of 5-Methylresorcin-Bonded Polyurethan Foam as a New Solid Phase Extractor for the Selective Separation of Mercury Ions from Natural Water Samples [J].
Burham, N. .
CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2008, 6 (04) :641-650
[5]   Determination of Hg2+ on poly(vinylferrocenium) (PVF+)-modified platinum electrode [J].
Celebi, Mutlu Soenmez ;
Ozyoruk, Haluk ;
Yildiz, Attila ;
Abaci, Serdar .
TALANTA, 2009, 78 (02) :405-409
[6]   Solid-phase extraction of iron(III) with an ion-imprinted functionalized silica gel sorbent prepared by a surface imprinting technique [J].
Chang, Xijun ;
Jiang, Na ;
Zheng, Hong ;
He, Qun ;
Hu, Zheng ;
Zhai, Yunhui ;
Cui, Yuemei .
TALANTA, 2007, 71 (01) :38-43
[7]   Chitosan modified ordered mesoporous silica as micro-column packing materials for on-line flow injection-inductively coupled plasma optical emission spectrometry determination of trace heavy metals in environmental water samples [J].
Chen, Dahui ;
Hu, Bin ;
Huang, Chaozhang .
TALANTA, 2009, 78 (02) :491-497
[8]   Determination of ultra-trace amount methyl-, phenyl- and inorganic mercury in environmental and biological samples by liquid chromatography with inductively coupled plasma mass spectrometry after cloud point extraction preconcentration [J].
Chen, Jianguo ;
Chen, Hengwu ;
Jin, Xianzhong ;
Chen, Haiting .
TALANTA, 2009, 77 (04) :1381-1387
[9]   Ion-imprinted polymethacrylic microbeads as new sorbent for preconcentration and speciation of mercury [J].
Dakova, Ivanka ;
Karadjova, Irina ;
Georgieva, Ventsislava ;
Georgiev, George .
TALANTA, 2009, 78 (02) :523-529
[10]   Preparation of the diphenylcarbazone-functionalized silica gel and its application to on-line selective solid-phase extraction and determination of mercury by flow-injection spectrophotometry [J].
Fan, Jing ;
Qin, Yuxia ;
Ye, Cunling ;
Peng, Pingan ;
Wu, Chunlai .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 150 (02) :343-350