Solid phase extraction of trace Hg(II) on silica gel modified with 2-(2-oxoethyl)hydrazine carbothioamide and determination by ICP-AES

被引:112
|
作者
Chai, Xiaoli [1 ]
Chang, Xijun [1 ]
Hu, Zheng [1 ]
He, Qun [1 ]
Tu, Zhifeng [1 ]
Li, Zhenhua [1 ]
机构
[1] Lanzhou Univ, Dept Chem, Lanzhou 730000, Gansu, Peoples R China
关键词
Silica gel; 2-(2-Oxoethyl)hydrazine carbothioamide; Solid phase extraction; Hg(II); Inductively coupled plasma atomic emission spectrometry (ICP-AES); ATOMIC-ABSORPTION-SPECTROMETRY; OPTICAL-EMISSION-SPECTROMETRY; ENVIRONMENTAL WATER SAMPLES; SELECTIVE SEPARATION; SPECTROPHOTOMETRIC DETERMINATION; PRECONCENTRATION; MERCURY; ION; METALS; RESIN;
D O I
10.1016/j.talanta.2010.07.076
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a new 2-(2-oxoethyl)hydrazine carbothioamide modified silica gel (SG-OHC) sorbent was prepared and applied for preconcentration of trace mercury(II) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). The optimization of some analytical parameters affecting the adsorption of the analyte such as acidity, shaking time, sample now rate and volume, eluent condition, and interfering substances were investigated. At pH 3, the maximum static adsorption capacity of Hg(II) onto the SG-OHC was 37.5 mg g(-1). The quantitative recovery (>95%) of Hg(II) could be obtained using 2 mL of 0.5 mol L-1 HCl and 1% CS(NH2)(2) solution as eluent. Common coexisting substances did not interfere with the separation of mercury(II) under optimal conditions. The detection limit of present method was 0.10 ng mL(-1), and the relative standard deviation (RSD) was lower than 4.0% (n = 8). The prepared sorbent was successfully applied for the preconcentration of trace Hg(II) in certified and water samples with satisfactory results. (C) 2010 Elsevier BM. All rights reserved.
引用
收藏
页码:1791 / 1796
页数:6
相关论文
共 50 条
  • [1] Simultaneous trace multielement determination by ICP-OES after solid phase extraction with modified octadecyl silica gel
    Karbasi, Mohamad-Hadi
    Jahanparast, Babak
    Shamsipur, Mojtaba
    Hassan, Jalal
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 170 (01) : 151 - 155
  • [2] Solid phase extraction of trace metals in water and leafy vegetables using a resin functionalized with potassium 2-benzoylhydrazinecarbodithioate and determination by ICP-AES
    Kumar, B. N.
    Harinath, Y.
    Sathyanarayana, B.
    Suneeta, Y.
    Seshaiah, K.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2012, 92 (12) : 1341 - 1351
  • [3] Solid-phase extraction with injection of modified silica gel slurries into ETAAS for determination of Cu(II), Hg(II), Pd(II)
    D. N. Konshina
    M. Yu. Burylin
    R. Anashkin
    V. V. Konshin
    International Journal of Environmental Science and Technology, 2019, 16 : 2885 - 2894
  • [4] Solid-phase extraction with injection of modified silica gel slurries into ETAAS for determination of Cu(II), Hg(II), Pd(II)
    Konshina, D. N.
    Burylin, M. Yu.
    Anashkin, R.
    Konshin, V. V.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2019, 16 (07) : 2885 - 2894
  • [5] Determination of trace elements in food samples by ICP-AES after preconcentration with p-toluenesulfonylamide immobilized on silica gel and nanometer SiO2
    Qun He
    Xijun Chang
    Xinping Huang
    Zheng Hu
    Microchimica Acta, 2008, 160 : 147 - 152
  • [6] Determination of trace elements in food samples by ICP-AES after preconcentration with p-toluenesulfonylamide immobilized on silica gel and nanometer SiO2
    He, Qun
    Chang, Xijun
    Huang, Xinping
    Hu, Zheng
    MICROCHIMICA ACTA, 2008, 160 (1-2) : 147 - 152
  • [7] Selective solid-phase extraction of trace mercury(II) using a silica gel modified with diethylenetriamine and thiourea
    Yin Jiang
    Huatang Zhang
    Qun He
    Zheng Hu
    Xijun Chang
    Microchimica Acta, 2012, 178 : 421 - 428
  • [8] Selective solid-phase extraction of trace mercury(II) using a silica gel modified with diethylenetriamine and thiourea
    Jiang, Yin
    Zhang, Huatang
    He, Qun
    Hu, Zheng
    Chang, Xijun
    MICROCHIMICA ACTA, 2012, 178 (3-4) : 421 - 428
  • [9] Solid phase extraction of trace metals in seawater using morpholine dithiocarbamate-loaded amberlite XAD-4 and determination by ICP-AES
    Rao, GPC
    Veni, SS
    Pratap, K
    Rao, YK
    Seshaiah, K
    ANALYTICAL LETTERS, 2006, 39 (05) : 1009 - 1021
  • [10] Determination of trace metal fractionation in aqueous solutions using a solid phase extraction flow injection system on-line coupled to ICP-AES
    Puls, Christoph
    Limbeck, Andreas
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (10) : 1434 - 1440