The effect of image quality on the reliability of OCT angiography measurements in patients with diabetes

被引:37
作者
Czako, Cecilia [1 ]
Istvan, Lilla [1 ]
Ecsedy, Monika [1 ]
Recsan, Zsuzsa [1 ]
Sandor, Gabor [1 ]
Benyo, Fruzsina [1 ]
Horvath, Hajnalka [1 ]
Papp, Andras [1 ]
Resch, Miklos [1 ]
Borbandy, Agnes [1 ]
Nagy, Zoltan Zsolt [1 ]
Kovacs, Illes [1 ]
机构
[1] Semmelweis Univ, Dept Ophthalmol, 26 Ulloi St, H-1085 Budapest, Hungary
关键词
OCT angiography; Image quality; Retinal vessel density; Diabetic retinopathy; COHERENCE TOMOGRAPHY ANGIOGRAPHY; FOVEAL AVASCULAR ZONE; VESSEL DENSITY-MEASUREMENTS; SIGNAL STRENGTH; FLUORESCEIN ANGIOGRAPHY; LAYER; RETINOPATHY; REPEATABILITY; REPRODUCIBILITY; EYES;
D O I
10.1186/s40942-019-0197-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundThis study aimed to determine the relationship between image quality and measurement repeatability of optical coherence tomography angiography (OCTA) parameters in patients with non-proliferative diabetic retinopathy.MethodsA total of 100 eyes of 50 patients were included in the study. Three OCTA images were obtained consecutively during one session of imaging in all patients using the RTVue AngioVue OCTA device. We applied the signal strength index (SSI) provided by the RTVue system to define scan quality. Superficial vessel density (VD) in the central 3x3 mm macular and in the perifoveal region, as well as foveal avascular zone (FAZ) area were evaluated by the AngioAnalytics software for each scan from three consecutive measurements, whereby measurement repeatability of the OCTA parameters were calculated. The effect of SSI value on OCTA parameters, as well as on measurement errors was assessed.ResultsValues of SSI ranged from 30 to 85 with an overall mean of 61.7910.38. Mean SSI values showed significant positive correlation with the mean retinal capillary vessel density values, but not with non-flow area. Repeatability of OCTA parameters was generally improved with higher SSI values. We calculated a mean correction factor of 0.22% (95% CI 0.20-0.24 mu m; p<0.001) for VD at the 3x3 mm macular scan, 0.23% (95% CI 0.21-0.26%; p<0.001) for perifoveal VD and - 0.001 mm(2) (95% CI - 0.001 to 0.002; p=0.001) for the non-flow area for each unit increase in SSI for the comparison of images with different SSI values.ConclusionsThe influence of image quality on OCTA metrics should be considered for image comparisons during follow-up to avoid misinterpretation of small changes in OCTA parameters in patients with diabetes.
引用
收藏
页数:7
相关论文
共 56 条
[1]   Impact of image quality on OCT angiography based quantitative measurements [J].
Al-Sheikh M. ;
Falavarjani K.G. ;
Akil H. ;
Sadda S.R. .
International Journal of Retina and Vitreous, 3 (1)
[2]   Repeatability of automated vessel density measurements using optical coherence tomography angiography [J].
Al-Sheikh, Mayss ;
Tepelus, Tudor Cosmin ;
Nazikyan, Tigran ;
Sadda, SriniVas R. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (04) :449-452
[3]   Test-retest variability in structural parameters measured with glaucoma imaging devices [J].
Araie, Makoto .
JAPANESE JOURNAL OF OPHTHALMOLOGY, 2013, 57 (01) :1-24
[4]   RETINAL MICROCIRCULATION IN PATIENTS WITH DIABETES-MELLITUS - DYNAMIC AND MORPHOLOGICAL ANALYSIS OF PERIFOVEAL CAPILLARY NETWORK [J].
AREND, O ;
WOLF, S ;
JUNG, F ;
BERTRAM, B ;
POSTGENS, H ;
TOONEN, H ;
REIM, M .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1991, 75 (09) :514-518
[5]  
BRESNICK GH, 1984, ARCH OPHTHALMOL-CHIC, V102, P1286
[6]   NEW INSIGHTS INTO THE PATHOANATOMY OF DIABETIC MACULAR EDEMA Angiographic Patterns and Optical Coherence Tomography [J].
Byeon, Suk Ho ;
Chu, Young Kwang ;
Hong, Young Taek ;
Kim, Min ;
Kang, Hae Min ;
Kwon, Oh Woong .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2012, 32 (06) :1087-1099
[7]   Relationship between retinal nerve fiber layer measurement and signal strength in optical coherence tomography [J].
Cheung, Carol Yim Lui ;
Leung, Christopher Kai Shun ;
Lin, Dusheung ;
Pang, Chi-Pui ;
Lam, Dennis Shun Chiu .
OPHTHALMOLOGY, 2008, 115 (08) :1347-1351
[8]   Quantitative optical coherence tomography angiography of macular vascular structure and foveal avascular zone in glaucoma [J].
Choi, Jaewan ;
Kwon, Junki ;
Shin, Joong Won ;
Lee, Jiyun ;
Lee, Saem ;
Kook, Michael S. .
PLOS ONE, 2017, 12 (09)
[9]   Normative Data for Vascular Density in Superficial and Deep Capillary Plexuses of Healthy Adults Assessed by Optical Coherence Tomography Angiography [J].
Coscas, Florence ;
Sellam, Alexandre ;
Glacet-Bernard, Agnes ;
Jung, Camille ;
Goudot, Mathilde ;
Miere, Alexandra ;
Souied, Eric H. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (09) :OCT211-OCT223
[10]   CAPILLARY PLEXUS ANOMALIES IN DIABETIC RETINOPATHY ON OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY [J].
Couturier, Aude ;
Mane, Valerie ;
Bonnin, Sophie ;
Erginay, Ali ;
Massin, Pascale ;
Gaudric, Alain ;
Tadayoni, Ramin .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2015, 35 (11) :2384-2391