On the seismic behavior of cylindrical base-isolated liquid storage tanks excited by long-period ground motions

被引:85
|
作者
Shekari, M. R. [1 ]
Khaji, N. [1 ]
Ahmadi, M. T. [1 ]
机构
[1] Tarbiat Modares Univ, Dept Civil Engn, Tehran, Iran
关键词
FRICTION PENDULUM SYSTEM; NEAR-FAULT MOTIONS; BE-FE; EARTHQUAKE; VIBRATION; ROCKING;
D O I
10.1016/j.soildyn.2010.04.008
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
A common effective method to reduce the seismic response of liquid storage tanks is to isolate them at base using base-isolation systems. It has been observed that in many earthquakes, the foregoing systems significantly affect on the whole system response reduction. However, in exceptional cases of excitation by long-period shaking, the base-isolation systems could have adverse effects. Such earthquakes could cause tank damage due to excessive liquid sloshing. Therefore, the numerical seismic response of liquid storage tanks isolated by bilinear hysteretic bearing elements is investigated under long-period ground motions in this research. For this purpose, finite shell elements for the tank structure and boundary elements for the liquid region are employed. Subsequently, fluid-structure equations of motion are coupled with governing equation of base-isolation system, to represent the whole system behavior. The governing equations of motion of the whole system are solved by an iterative and step-by-step algorithm to evaluate the response of the whole system to the horizontal component of three ground motions. The variations of seismic shear forces, liquid sloshing heights, and tank wall radial displacements are plotted under various system parameters such as the tank geometry aspect ratio (height to radius), and the flexibility of the isolation system, to critically examine the effects of various system parameters on the effectiveness of the base-isolation systems against long-period ground motions. From these analyses, it may be concluded that with the installation of this type of base-isolation system in liquid tanks, the dynamic response of tanks during seismic ground motions can be considerably reduced. Moreover, in the special case of long-period ground motions, the seismic response of base-isolated tanks may be controlled by the isolation system only at particular conditions of slender and broad tanks. For the case of medium tanks, remarkable attentions would be required to be devoted to the design of base-isolation systems expected to experience long-period ground motions. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:968 / 980
页数:13
相关论文
共 50 条
  • [1] Seismic analysis of base-isolated liquid storage tanks on the layered ground
    Kim, MK
    Lim, YM
    Cho, SY
    Lee, K
    PROCEEDINGS OF US-KOREA WORKSHOP ON NEW FRONTIER IN INFRASTRUCTURAL/SEISMIC ENGINEERING, 2000, : 259 - 272
  • [2] Seismic response of base-isolated liquid storage tanks
    Shrimali, MK
    Jangid, RS
    JOURNAL OF VIBRATION AND CONTROL, 2003, 9 (10) : 1201 - 1218
  • [3] Seismic analysis of base-isolated liquid storage tanks
    Shrimali, MK
    Jangid, RS
    JOURNAL OF SOUND AND VIBRATION, 2004, 275 (1-2) : 59 - 75
  • [4] Seismic Control of Base-Isolated Liquid Storage Tanks Subjected to Bi-directional Strong Ground Motions
    Vern, Sourabh
    Shrimali, M. K.
    Bharti, S. D.
    Datta, T. K.
    Farsangi, Ehsan Noroozinejad
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2022, 47 (04) : 4511 - 4530
  • [5] Seismic Control of Base-Isolated Liquid Storage Tanks Subjected to Bi-directional Strong Ground Motions
    Sourabh Vern
    M. K. Shrimali
    S. D. Bharti
    T. K. Datta
    Ehsan Noroozinejad Farsangi
    Arabian Journal for Science and Engineering, 2022, 47 : 4511 - 4530
  • [6] Equivalent linear stochastic seismic analysis of cylindrical base-isolated liquid storage tanks
    Curadelli, O.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2013, 83 : 166 - 176
  • [7] Seismic response reduction analysis of large chassis base-isolated structure under long-period ground motions
    Feiyan Li
    Linjian Wang
    Yingxiong Wu
    EarthquakeResearchAdvances, 2021, 1 (02) : 49 - 56
  • [8] Response of base-isolated liquid storage tanks to near-fault motions
    Jadhav, M. B.
    Jangid, R. S.
    STRUCTURAL ENGINEERING AND MECHANICS, 2006, 23 (06) : 615 - 634
  • [9] Seismic response of base isolated liquid storage ground tanks
    Seleemah, Ayman A.
    El-Sharkawy, Mohamed
    AIN SHAMS ENGINEERING JOURNAL, 2011, 2 (01) : 33 - 42
  • [10] Resonant behaviour of base-isolated high-rise buildings under long-period ground motions
    Ariga, T.
    Kanno, Y.
    Takewaki, I.
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2006, 15 (03): : 325 - 338