Adaptive Motion Artifact Reducing Algorithm for Wrist Photoplethysmography Application

被引:1
作者
Zhao, Jingwei [1 ]
Wang, Guijin [1 ]
Shi, Chenbo [1 ]
机构
[1] Tsinghua Univ, Dept Elect Engn, Beijing 100084, Peoples R China
来源
BIOPHOTONICS: PHOTONIC SOLUTIONS FOR BETTER HEALTH CARE V | 2016年 / 9887卷
关键词
Adaptive filter; heart rate; motion artifact; PPG; wavelet filter; PCA;
D O I
10.1117/12.2228935
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Photoplethysmography(PPG) technology is widely used in wearable heart pulse rate monitoring. It might reveal the potential risks of heart condition and cardiopulmonary function by detecting the cardiac rhythms in physical exercise. However the quality of wrist photoelectric signal is very sensitive to motion artifact since the thicker tissues and the fewer amount of capillaries. Therefore, motion artifact is the major factor that impede the heart rate measurement in the high intensity exercising. One accelerometer and three channels of light with different wavelengths are used in this research to analyze the coupled form of motion artifact. A novel approach is proposed to separate the pulse signal from motion artifact by exploiting their mixing ratio in different optical paths. There are four major steps of our method: preprocessing, motion artifact estimation, adaptive filtering and heart rate calculation. Five healthy young men are participated in the experiment. The speeder in the treadmill is configured as 12km/h, and all subjects would run for 3-10 minutes by swinging the arms naturally. The final result is compared with chest strap. The average of mean square error (MSE) is less than 3 beats per minute (BPM/min). Proposed method performed well in intense physical exercise and shows the great robustness to individuals with different running style and posture.
引用
收藏
页数:7
相关论文
共 8 条
[1]   Improved elimination of motion artifacts from a photoplethysmographic signal using a Kalman smoother with simultaneous accelerometry [J].
Lee, Boreom ;
Han, Jonghee ;
Baek, Hyun Jae ;
Shin, Jae Hyuk ;
Park, Kwang Suk ;
Yi, Won Jin .
PHYSIOLOGICAL MEASUREMENT, 2010, 31 (12) :1585-1603
[2]  
Lee HW, 2007, INT J CONTROL AUTOM, V5, P701
[3]  
Lee Juwon, 2010, Journal of Information and Communication Convergence Engineering, V8, P201
[4]  
Raghuram M., 2012, 2012 Proceedings of IEEE International Symposium on Medical Measurements and Applications (MeMeA 2012), DOI 10.1109/MeMeA.2012.6226643
[5]   ICA-Based Improved DTCWT Technique for MA Reduction in PPG Signals With Restored Respiratory Information [J].
Ram, M. Raghu ;
Madhav, K. Venu ;
Krishna, Ette Hari ;
Komalla, Nagarjuna Reddy ;
Sivani, Kosaraju ;
Reddy, K. Ashoka .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (10) :2639-2651
[6]   A Novel Approach for Motion Artifact Reduction in PPG Signals Based on AS-LMS Adaptive Filter [J].
Ram, M. Raghu ;
Madhav, K. Venu ;
Krishna, E. Hari ;
Komalla, Nagarjuna Reddy ;
Reddy, K. Ashoka .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2012, 61 (05) :1445-1457
[7]   Simultaneous recording of skin blood pulsations at different vascular depths by multiwavelength photoplethysmography [J].
Spigulis, Janis ;
Gailite, Lasma ;
Lihachev, Alexey ;
Erts, Renars .
APPLIED OPTICS, 2007, 46 (10) :1754-1759
[8]   Wavelet Packet Algorithm to Feature Extraction of Heart Sound [J].
Zhang, Guohua ;
Liu, Shixuan .
EQUIPMENT MANUFACTURING TECHNOLOGY AND AUTOMATION, PTS 1-3, 2011, 317-319 :1211-1214