Effect of vertical internals on the pressure drop in a gas-solid fluidized bed

被引:9
|
作者
Taofeeq, Haidar [1 ,3 ,4 ]
Al-Dahhan, Muthanna H. [1 ,2 ]
机构
[1] Missouri Univ Sci & Technol, Multiphase Reactors Engn & Applicat Lab MReal, Dept Chem & Biochem Engn, Rolla, MO 65409 USA
[2] Cihan Univ Erbil, Erbil, Iraq
[3] Al Nahrain Univ, Dept Chem Engn, Coll Engn, Baghdad, Iraq
[4] Al Nahrain Univ, Prosthet & Orthot Engn Dept, Coll Engn, Baghdad, Iraq
来源
关键词
pressure drop; vertical internals; pressure transducer; gas-solid fluidized bed; BUBBLE CHARACTERIZATION; BINARY-MIXTURE; HEAT-TRANSFER; HYDRODYNAMICS; EXPANSION; PARTICLES; VELOCITY; BAFFLES;
D O I
10.1002/cjce.23299
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this work, the pressure drop at the wall and the radial profiles of pressure drop along the bed height have been measured using a differential pressure transducer and pressure probe-differential pressure transducer in a gas-solid fluidized bed with a 0.14m inside diameter. Two types of circular arrangements of intense vertical internals (0.0254 and 0.0127m diameter), two kinds of solid particles of Geldart B type (glass beads and aluminum oxide), and four selected superficial gas velocities in terms of u/u(mf) have been used to study the impact of these different designs, as well as the physical and operating variables on the pressure drop measured at the wall of the bed and the radial pressure drop inside the fluidized bed. It has been experimentally demonstrated that the 0.0254m internals can reduce the pressure drop at the wall and the radial pressure drop inside the bed by about 10 % when compared to without internals, and this result holds true for both kinds of solids used. However, the implementation of 0.0127m internals inside the gas-solid fluidized bed leads to a decrease in the pressure drop and radial pressure drop in the case of glass bead solid particles and an increase in the pressure drop in the case of aluminum oxide solid particles. The experimental results in the form of relevant dimensionless groups have been correlated using the statistical analysis software of JMP 12, due to the big difference between the experimental results of this work and the predicted values from the available correlations in the literature. The new correlation has been developed with a mean relative deviation value of 1.08 % between the experimental and predicted values.
引用
收藏
页码:2185 / 2205
页数:21
相关论文
共 50 条
  • [1] Flow regimes in gas-solid fluidized bed with for vertical internals
    Taofeeq, Haidar
    Al-Dahhan, Muthanna
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2018, 138 : 87 - 104
  • [2] Pressure drop in the gas-solid stirred fluidized bed
    Li, Fan
    Feng, Lian-Fang
    Gu, Xue-Ping
    Wang, Kai
    Liu, Bo
    Gao Xiao Hua Xue Gong Cheng Xue Bao/Journal of Chemical Engineering of Chinese Universities, 2002, 16 (04): : 384 - 388
  • [3] Heat transfer and hydrodynamics in a gas-solid fluidized bed with vertical immersed internals
    Taofeeq, Haidar
    Al-Dahhan, Muthanna
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 122 : 229 - 251
  • [4] Impact of vertical internals on the hydrodynamics and separation performance of a gas-solid separation fluidized bed
    Lv, Bo
    Deng, Xiaowei
    Luo, Zhenfu
    Fu, Yanhong
    Chen, Changshuai
    Xu, Xuan
    POWDER TECHNOLOGY, 2020, 360 (360) : 577 - 587
  • [5] Experimental study of the effect of internals on optimizing gas-solid flow in a circulating fluidized bed
    Wang, Cuiping
    Lu, Zi'an
    Ll, Dingkai
    POWDER TECHNOLOGY, 2008, 184 (03) : 267 - 274
  • [6] Distributor to bed pressure drop ratio in promoted gas-solid fluidized beds
    Department of Civil Engineering, National Institute of Technology, Rourkela 769008
    不详
    J Inst Eng India: Chem Eng Div, 2007, MAR. (11-15):
  • [7] MONITORING OF A GAS-SOLID REACTION IN A FLUIDIZED BED BY MEASURING THE PRESSURE DROP.
    Muller, C.
    Flament, G.
    International chemical engineering, 1988, 28 (01): : 62 - 74
  • [8] Monitoring of a Gas-Solid Reaction in a Fluidized Bed by Pressure Drop Measurement.
    Muller, C.
    Flamant, G.
    Entropie Paris, 1986, 22 (127): : 37 - 47
  • [9] THE EFFECT OF MULTITUBE INTERNALS UPON THE ELUTRIATION RATE FROM GAS-SOLID FLUIDIZED-BED
    KATO, K
    KANBARA, S
    SHIBASAKI, H
    OZAWA, K
    HANZAWA, T
    KAGAKU KOGAKU RONBUNSHU, 1986, 12 (05) : 615 - 619
  • [10] POWER REQUIREMENT AND PRESSURE-DROP IN THE GAS-SOLID STIRRED FLUIDIZED-BED
    TAKAHASHI, T
    TANAKA, Z
    KASENO, S
    KAGAKU KOGAKU RONBUNSHU, 1988, 14 (02) : 189 - 194